Under COSHH Regulations 2002 (Regulation 6), employers must conduct task-specific risk assessments for welding fume exposure, implementing adequate Local Exhaust Ventilation (LEV) per HSG258 and Respiratory Protective Equipment (RPE) to control exposure below EH40/2005 Workplace Exposure Limits (WELs): 5 mg/m³ (8-hr TWA) for welding fume. HSE's 2019 WL3/STSU1 enforcement alert mandates engineering controls and medical surveillance for all welding activities. This audit-grade template provides a 5×5 risk matrix assessment covering mild steel (MMA, MIG, TIG) and stainless steel welding operations, addressing hexavalent chromium (Cr(VI)) exposure (0.025 mg/m³ WEL), metal fume fever, respiratory sensitisation (CLP H334, H317), and carcinogenicity (H350i). A manufacturer's Safety Data Sheet (SDS) alone does NOT satisfy Regulation 6 requirements—UK law mandates a workplace-specific assessment of task, duration, ventilation, and control measures. This template delivers compliant documentation for tender Pre-Qualification Questionnaires (PQQs), Principal Contractor audits, and CDM 2015 pre-construction information, ensuring residual risk ≤ 8 (Tolerable) through hierarchy of control: LEV extraction (HSG258 thorough examination every 14 months), on-tool fume extraction, RPE (FFP3 or powered air), health surveillance (HAVS/spirometry), and permit-to-work for confined spaces.
| Identified Hazard & Harm | Initial Risk (L×S) | Mandatory Engineering, Isolation & Procedural Controls | Residual Risk |
|---|---|---|---|
| 1. Inhalation of welding fume (mild steel: iron oxide, manganese; stainless steel: hexavalent chromium Cr(VI), nickel) Harm: Carcinogenic exposure (lung cancer from Cr(VI) H350i), metal fume fever, chronic obstructive pulmonary disease (COPD), respiratory sensitisation (asthma H334), manganese-induced Parkinsonism. Acute: throat irritation, nausea, headache. | 5 × 4 = 20 | Engineering: Install HSG258-compliant LEV with on-torch extraction (capture velocity ≥0.5 m/s at source) or backdraft booth (face velocity 0.5–1.0 m/s). Thorough examination every 14 months by competent person (P601). Administrative: Permit-to-weld in confined spaces; rotate welders to limit exposure duration; health surveillance (baseline & annual spirometry, Cr(VI) biological monitoring for stainless). PPE: Mandatory FFP3 or PAPR (TH3) with face-fit test (HSE INDG479) annually. Air monitoring: IOM sampler, 8-hr TWA <5 mg/m³ (mild steel) / <0.025 mg/m³ Cr(VI) (stainless). Prohibit welding without LEV operational (LOTO on power supply if LEV fails). | 3 × 2 = 6 |
| 2. Exposure to UV/IR radiation (arc eye, skin burns, long-term cataract risk) Harm: Photokeratitis ('arc eye'/'welder's flash') causing severe eye pain, tearing, photophobia within 6–12 hours. Erythema (skin burns) on exposed skin. Chronic: cataracts, retinal damage. | 5 × 3 = 15 | Engineering: Erect welding screens/curtains (BS EN ISO 25980) around welding bay to protect bystanders; use designated welding booths with non-reflective internal surfaces. Administrative: Permit-to-weld system; pre-task briefing on UV hazards; restrict access to welding area (signage: 'Welding in Progress – UV Hazard'). PPE: Auto-darkening welding helmet (BS EN 175:1997, shade 9–13 per BS EN 169:2002); flame-retardant coveralls (BS EN ISO 11611:2015 Class 2) covering all skin; UV-blocking side shields. Inspect helmet lens daily for cracks/scratches. | 2 × 2 = 4 |
| 3. Fire/explosion risk from flammable gases (acetylene, propane), oxygen enrichment, or ignition of combustibles Harm: Catastrophic explosion (acetylene >15% LEL), flashback into hoses/regulators, severe burns (>50% TBSA), fatalities. Oxygen-enriched atmosphere (<23.5% O₂) accelerates combustion of clothing/materials. | 3 × 5 = 15 | Engineering: Store gas cylinders upright, secured, segregated (oxygen >5 m from fuel gases), in ventilated external compound. Fit flashback arrestors (BS EN 730-1) on both regulator and torch ends. Use non-return valves. Administrative: Hot work permit system (10 m radius clearance of combustibles, fire watch for 60 min post-work). Leak-test hoses with soapy water (never flame). Prohibit oxygen for 'blowing down' or ventilation. Isolation: LOTO on gas supply valves; purge hoses before/after use. Emergency: CO₂/powder extinguishers within 5 m; emergency shut-off valves clearly marked. | 2 × 3 = 6 |
| 4. Electric shock from welding equipment (MMA/MIG/TIG sets operating at 240V AC supply, 20–80V OCV) Harm: Electrocution (ventricular fibrillation, cardiac arrest, fatality). Secondary injury from involuntary muscle contraction causing falls from height or contact with hot metal. | 3 × 5 = 15 | Engineering: Use 110V CTE (centre-tapped earth) supply via transformer for portable equipment. Ensure welding sets have RCD protection (30 mA, <40 ms trip). Insulate electrode holders; use spring-loaded 'dead man' switches. Administrative: Competent person (BS 7671:2018) to inspect PAT every 3 months in harsh environments. Prohibit welding in wet/damp conditions or on conductive surfaces without insulated matting. Isolation: LOTO on mains supply during maintenance; discharge capacitors before opening enclosures. PPE: Dry leather gauntlets (BS EN 12477); insulated footwear (BS EN ISO 20345 S3). | 2 × 3 = 6 |
| 5. Confined space hazards (oxygen depletion from inert shielding gases [Ar, CO₂], accumulation of toxic fumes, restricted egress) Harm: Asphyxiation (O₂ <19.5%), unconsciousness within seconds, fatality. Acute CO/NO₂ poisoning (dizziness, collapse). Delayed pulmonary oedema from NO₂ exposure (fatal within 24–72 hours). | 4 × 5 = 20 | Engineering: Forced mechanical ventilation (≥6 air changes/hour) with ducted extraction at low level (CO₂/Ar heavier than air). Continuous gas monitoring (O₂, CO, NO₂, LEL) with audible alarms (O₂ <19.5% / >23.5%; CO >30 ppm; NO₂ >0.5 ppm). Administrative: Confined Space Entry Permit (Confined Spaces Regulations 1997); trained standby person outside; emergency rescue plan with tripod/winch. Pre-entry atmospheric test; re-test every 30 min. Prohibit welding if O₂ <19.5% or ventilation fails. Isolation: LOTO on gas supplies; purge space before entry. PPE: Airline BA (not FFP3) if ventilation inadequate; harness with retrieval line. | 2 × 3 = 6 |
| Operative / Supervisor Name | Trade / Role & CSCS No. | Signature | Date & Time |
|---|---|---|---|
| 1. (Site Supervisor): | |||
| 2. | |||
| 3. | |||
| 4. |