Under COSHH Regulations 2002 Regulation 6, employers must conduct a task-specific risk assessment for WD-40 use—a manufacturer's Safety Data Sheet (SDS) alone does NOT satisfy this legal duty. WD-40 contains hydrocarbon solvents (CLP H-codes H222, H229, H304, H336; GHS02/GHS07) subject to HSE EH40/2005 Workplace Exposure Limits (800 mg/m³ 8-hr TWA for aliphatic hydrocarbons) and DSEAR 2002 flammable atmosphere controls. This audit-grade UK template delivers a 5×5 risk matrix, engineering controls (forced ventilation, LOTO, ignition source isolation), BS EN-coded PPE, and step-by-step safe-work sequences to reduce residual risk to ≤6 (Low). Suitable for manufacturing, maintenance, automotive, and facilities management operations across England, Scotland, Wales, and Northern Ireland. Designed for immediate download as a free UK Word (.DOC) file, this document integrates HSE Guidance HSG97 (maintenance), INDG136 (COSHH essentials), and EH40/2005 occupational hygiene monitoring requirements, ensuring full legal compliance and audit readiness for HSE inspector visits, ISO 45001 certification, and tender Pre-Qualification Questionnaire (PQQ) submissions.
| Identified Hazard & Harm | Initial Risk (L×S) | Mandatory Engineering, Isolation & Procedural Controls | Residual Risk |
|---|---|---|---|
| 1. Flammable aerosol ignition / fire / explosion (DSEAR 2002 dangerous substance) Harm: Severe burns, explosion injuries, fatalities; property damage; breach of Regulatory Reform (Fire Safety) Order 2005 | 4 × 5 = 20 | ELIMINATE ignition sources within 3 m: no smoking, hot work, naked flames, or non-ATEX electrical equipment. ISOLATE: LOTO all energised circuits/machinery before application. VENTILATE: forced mechanical ventilation ≥10 air changes/hour (ACH) to maintain vapour concentration <10% LEL. SUBSTITUTE: consider non-aerosol WD-40 bulk liquid with manual pump applicator to reduce flammable atmosphere. STORE: fireproof metal cabinet (max 50 L aerosols), away from oxidisers, <25°C. TRAIN: DSEAR competent person sign-off. MONITOR: portable LEL meter (calibrated) if confined space or poorly ventilated area. EMERGENCY: CO₂ or dry powder extinguisher within 10 m; never use water jet on aerosol fire. | 2 × 3 = 6 |
| 2. Inhalation of hydrocarbon vapours causing narcosis, dizziness, headache (H336 STOT SE 3) Harm: Central nervous system depression, loss of consciousness, asphyxiation in confined spaces; chronic exposure may cause liver/kidney damage | 4 × 3 = 12 | ENGINEERING: Install/verify LEV (HSE HSG258) with face velocity ≥0.5 m/s at point of application; test LEV every 14 months (COSHH Reg 9). WORK OUTDOORS or in well-ventilated area wherever practicable. CONFINED SPACE: Permit-to-Work (PTW), continuous forced ventilation, atmospheric monitoring (O₂ ≥19.5%, <10% LEL, <50% WEL), standby rescue. LIMIT DURATION: rotate tasks, max 15-min continuous spraying per operative per hour. RESPIRATORY PPE: FFP3(SL) or half-mask with A1 filter (BS EN 14387) if WEL >50%. HEALTH SURVEILLANCE: annual respiratory questionnaire (HSE guidance MS25) for regular users (>1 hr/week). TRAINING: COSHH essentials sheet S100, recognition of narcosis symptoms. | 2 × 2 = 4 |
| 3. Aspiration toxicity if swallowed and enters lungs (H304 Asp. Tox. 1—can be fatal) Harm: Chemical pneumonitis, pulmonary oedema, respiratory failure, death; low viscosity hydrocarbons readily aspirated | 2 × 5 = 10 | ELIMINATE ingestion risk: NEVER decant into unmarked containers or drinks bottles. LABEL: original aerosol only; if bulk dispenser used, label per CLP Regulation (EC) 1272/2008. PROHIBIT eating/drinking/smoking in application area (COSHH Reg 7 hygiene). FIRST AID TRAINING: all operatives must know DO NOT INDUCE VOMITING (P301+P310, P331). EMERGENCY: immediate 999 call, place casualty in recovery position, monitor breathing, administer O₂ if trained. STORE: locked chemical store, segregated from food/drink areas. SUPERVISION: competent person present during bulk transfer operations. | 1 × 5 = 5 |
| 4. Skin contact causing defatting dermatitis, irritation, sensitisation (prolonged/repeated exposure) Harm: Dry, cracked, inflamed skin; secondary infection; occupational dermatitis (reportable under RIDDOR 2013 if work-related skin disease diagnosed) | 5 × 2 = 10 | BARRIER: nitrile gloves BS EN ISO 374-1:2016 Type B (KPT), minimum 0.38 mm, change every 30 min or immediately if contaminated. PRE-WORK: apply barrier cream (HSE-recognised, e.g. Stokoderm® Aqua PURE) to exposed skin. POST-WORK: wash hands with mild soap and water (not solvents), dry thoroughly, apply moisturiser (e.g. Stokolan® Light PURE). HYGIENE: dedicated washing facilities, hot water, soap, disposable towels. HEALTH SURVEILLANCE: annual skin inspection by occupational health nurse for regular users; refer to dermatologist if dermatitis suspected. TRAINING: HSE INDG330 (skin at work), correct glove donning/doffing technique. REPORT: all cases of work-related dermatitis to HSE via RIDDOR online. | 2 × 2 = 4 |
| 5. Pressurised container rupture due to heat exposure (>50°C) or mechanical damage (H229) Harm: Violent explosion, flying metal fragments, severe lacerations, burns, eye injuries; secondary fire ignition | 3 × 4 = 12 | STORAGE: cool, dry, well-ventilated area away from direct sunlight, radiators, hot pipes; temperature <25°C (ideally <20°C). PROTECT: store upright in original packaging, never in vehicle boot/direct sunlight in summer. PROHIBIT: piercing, crushing, incineration of empty cans (P251). DISPOSAL: empty cans via licensed hazardous waste contractor (EWC code 15 01 11* or 16 05 04*); never dispose in general waste or burn. TRANSPORT: secure in vehicle to prevent rolling/impact; carry max 333 aerosol cans (ADR 1.1.3.6 limited quantity exemption). INSPECT: reject dented, corroded, or leaking cans; quarantine and return to supplier. TRAINING: Manual Handling Operations Regulations 1992, ADR awareness for drivers. | 1 × 4 = 4 |
Retrieve site-specific COSHH assessment (this document) and WD-40 SDS (latest revision). Verify task is authorised by Competent Person (COSHH Reg 12). Inspect Local Exhaust Ventilation (LEV) system: check airflow indicator, test face velocity ≥0.5 m/s with anemometer, confirm last thorough examination date (≤14 months, COSHH Reg 9). Identify and ISOLATE all ignition sources within 3 m radius: switch off non-ATEX electrical equipment, apply LOTO, post 'No Hot Work' signage, remove smoking materials. Check ambient temperature <25°C; if confined space, obtain Permit-to-Work and set up continuous atmospheric monitoring (O₂, LEL, hydrocarbon vapour). Issue and don all mandatory PPE: nitrile gloves (BS EN ISO 374-1:2016), safety spectacles (BS EN 166), FFP2(SL) or FFP3 respirator if LEV unavailable, antistatic S3 footwear (BS EN ISO 20345:2011). Position CO₂ or dry powder fire extinguisher within 10 m. Confirm first-aider on site and emergency contact numbers displayed.
Visually inspect aerosol can for dents, corrosion, leaks, or bulging (reject if damaged—risk of rupture H229). Confirm CLP hazard label intact and legible: GHS02 (flame), GHS07 (exclamation), GHS08 (health hazard), H-codes H222, H229, H304, H336, and P-codes P210, P211, P251, P261, P271, P301+P310, P304+P340, P410+P412. Check batch number and expiry date (if stated). Shake can gently for 5 seconds to mix contents—do NOT shake vigorously or near face. Remove any protective cap and inspect nozzle/straw for blockages. If using extension straw, attach securely to prevent detachment during spraying. Ensure can is at room temperature (15–25°C); if cold, allow to warm naturally—never heat artificially. Position spill kit (absorbent pads, vermiculite, non-sparking scoop, metal bin) within 2 m of work area.
Activate LEV system and confirm extraction airflow. Hold aerosol can upright (or inverted if design permits) 15–20 cm from target surface. Apply in short 1–2 second bursts, allowing 5 seconds between applications to minimise vapour build-up. Direct spray away from face, other persons, and ignition sources. If using extension straw, ensure tip is stable and directed precisely to avoid overspray. Work in well-ventilated area or outdoors; if indoors, maintain forced ventilation ≥10 ACH. Limit continuous spraying to 15 minutes per operative per hour to control inhalation exposure (EH40/2005 WEL 800 mg/m³ 8-hr TWA). Wipe excess product with lint-free cloth; dispose of contaminated rags in metal bin with self-closing lid (spontaneous combustion risk). Monitor for symptoms of narcosis (dizziness, headache, nausea)—if present, cease work immediately, move to fresh air, and report to supervisor. If confined space, continuously monitor LEL and hydrocarbon vapour concentration; evacuate if LEL >10% or vapour >50% WEL.
After final application, maintain LEV operation for minimum 10 minutes to clear residual hydrocarbon vapours. Do NOT re-energise isolated equipment or reintroduce ignition sources until vapour concentration confirmed <10% LEL (use calibrated portable gas detector if confined space or poorly ventilated area). Wipe down treated surfaces with clean, dry cloth to remove excess product and reduce slip hazard. Inspect work area for spills; if present, absorb immediately with vermiculite or absorbent pads, sweep into metal container, and dispose as hazardous waste (EWC 15 02 02*). Ventilate area for further 10 minutes if strong odour persists. Once vapour clearance confirmed, remove LOTO devices in reverse order of application, following site energy isolation procedure. Replace any 'No Hot Work' signage with normal operational signs. Store aerosol can upright in designated fireproof cabinet, away from heat sources and oxidisers, temperature <25°C.
Remove PPE in following order to minimise cross-contamination: (1) Gloves—peel off inside-out, avoiding skin contact with outer surface, dispose in general waste or launder if reusable; (2) Safety spectacles—handle by arms only, clean lenses with alcohol wipe if contaminated; (3) Respirator—remove by grasping straps (not facepiece), dispose if single-use (FFP2/FFP3) or store in clean, dry container if reusable; (4) Footwear—inspect soles for contamination, clean if necessary. Wash hands and forearms thoroughly with mild soap and warm water for minimum 20 seconds, paying attention to wrists and between fingers—do NOT use solvents or abrasive cleaners on skin. Dry hands with disposable paper towel. Apply moisturising cream (e.g. Stokolan® Light PURE) to prevent dermatitis. Inspect skin for redness, dryness, or irritation; report any concerns to supervisor and occupational health. Change into clean work clothing if contaminated. Do NOT eat, drink, or smoke until hands washed.
Segregate and dispose of all WD-40-related waste via licensed hazardous waste contractor: (1) Empty aerosol cans—EWC code 15 01 11* (metallic packaging containing dangerous residues) or 16 05 04* (gases in pressure containers); (2) Contaminated rags/absorbents—EWC code 15 02 02* (absorbents contaminated by dangerous substances); (3) Waste product—EWC code 13 07 03* (other fuels including mixtures). Complete Hazardous Waste Consignment Note (England/Wales) or Special Waste Consignment Note (Scotland). Record task details in COSHH exposure log: operative name, date, duration, product quantity used, LEV test result, any symptoms reported. Update Health Surveillance register if operative exposed >1 hr/week. Review this COSHH assessment annually (COSHH Reg 6(3)) or immediately if: (a) significant change in work process, (b) new WD-40 formulation/SDS issued, (c) incident/near-miss occurs, (d) health surveillance identifies adverse trend. Conduct toolbox talk with operatives to capture lessons learned and improvement suggestions. File completed assessment in site COSHH register and upload to company H&S management system.
| Operative / Supervisor Name | Trade / Role & CSCS No. | Signature | Date & Time |
|---|---|---|---|
| 1. (Site Supervisor): | |||
| 2. | |||
| 3. | |||
| 4. |
Need site-specific compliance documentation instead of a static template? Explore the core SafeSequence® UK software modules hosted in AWS London (eu-west-2):