SafeSequence › UK Safety Template Library › High-Volume UK COSHH › COSHH Assessment for Diesel Fuel (ULSD) & Diesel Engine Exhaust Emissions (DEEE) UK
Reference UK COSHH Example • High-Volume UK COSHH

COSHH Assessment for Diesel Fuel (ULSD) & Diesel Engine Exhaust Emissions (DEEE) UK

Under COSHH Regulations 2002 Regulation 6, UK employers must conduct task-specific risk assessments for diesel fuel (ULSD) and diesel engine exhaust emissions (DEEE) exposure, applying HSE EH40/2005 Workplace Exposure Limits (0.05 mg/m³ elemental carbon for DEEE), INDG286 guidance, DSEAR 2002 fire/explosion controls, and CLP GHS08 carcinogen labelling (H350, H340, H304). A manufacturer's Safety Data Sheet (SDS) alone does NOT satisfy Regulation 6; employers must assess task-specific exposure routes, implement engineering controls (LEV, enclosed cabs, HEPA filtration), and reduce residual risk to ≤6 (5×5 matrix). This audit-grade COSHH assessment provides 5×5 risk scoring, BS EN PPE specifications, emergency spill procedures, and UK HSE-compliant control hierarchies for diesel refuelling, plant operation, and maintenance tasks involving ULSD and DEEE exposure.

Statutory FrameworkCOSHH Regulations 2002 Reg 6, HSE EH40/2005 WELs, INDG286 Diesel Exhaust, DSEAR 2002, CLP GHS08
Classification**UN/GHS Classification (CLP Regulation EC 1272/2008):** - **Diesel Fuel (ULSD):** UN 1202, Class 3 Flammable Liquid, Packing Group III. CLP: Flam. Liq. 3 (H226), Carc. 2 (H351), Asp. Tox. 1 (H304), Aquatic Chronic 2 (H411), Skin Irrit. 2 (H315), STOT SE 3 (H336). - **Diesel Engine Exhaust Emissions (DEEE):** IARC Group 1 Carcinogen. CLP: Carc. 1A (H350), Muta. 1B (H340). Contains respirable crystalline silica (RCS), nitrogen oxides (NOx), carbon monoxide (CO), particulate matter (PM2.5/PM10). - **HSE EH40/2005 WELs:** DEEE (as elemental carbon): 0.05 mg/m³ 8-hr TWA. Diesel fuel vapour (as total hydrocarbon): 100 mg/m³ 8-hr TWA (indicative). - **DSEAR 2002:** Diesel fuel flash point 52–96°C; requires explosion-protected equipment in confined spaces and bonding/earthing during transfer.
Required Plant / KitDiesel fuel transfer pump with bonding/earthing clamps (DSEAR-compliant) • Portable gas detector (LEL, CO, NOx, O₂) calibrated to HSE standards • Type-approved spill kit: absorbent pads, booms, disposal bags (min. 50 L capacity) • Local Exhaust Ventilation (LEV) system with HEPA H13 filtration (TH2 examination certificate) • Lockout/Tagout (LOTO) kit for plant isolation during maintenance
Site Sign-Off StatusRequires Competent Person Verification
Bid-Winning PCI Tender Studio or Instant Voice Customization

Bidding a Contract or Need This COSHH Customized for Your Site?

Drop your client's Pre-Construction Information (PCI) PDF into our Tender Studio to generate a page-cited 5×5 RAMS & PQQ pack—or download our free blank Word (.doc) shell below.

Auto-Fill via 45s Voice / CLP

1. Mandatory Personal Protective Equipment (BS EN Standards)

BS EN ISO 374-1:2016 Type B (KPT), BS EN 374-4:2013 degradation Class 2
Nitrile chemical-resistant gloves (min. 0.38 mm thickness)
Prevent dermal absorption of diesel fuel hydrocarbons (H304, H315) and carcinogenic PAHs during refuelling and spill response.
BS EN 149:2001+A1:2009 (FFP3 NR) or BS EN 140:1999 + BS EN 143:2000 (P3)
FFP3 (NR) disposable respirator or half-mask with P3 filters
Protect against inhalation of diesel particulate matter (PM2.5), elemental carbon (EH40/2005 WEL 0.05 mg/m³), and carcinogenic DEEE (H350, H340).
BS EN ISO 20345:2011 S3 FO SRC
Safety boots with fuel-resistant sole and anti-static properties
Prevent slips on diesel-contaminated surfaces (SRC), fuel oil penetration (FO), and static discharge ignition risk (DSEAR 2002).
BS EN 166:2001 Class 1 Optical, 3 (liquid droplet), 4 (coarse dust)
Safety spectacles with side shields (sealed or indirect ventilation)
Prevent eye contact with diesel fuel splashes (H315 irritant) and airborne particulate during refuelling and maintenance.

2. 5×5 Hazard Risk Assessment Matrix (HASAWA 1974 / CDM 2015)

Identified Hazard & HarmInitial Risk (L×S)Mandatory Engineering, Isolation & Procedural ControlsResidual Risk
1. Inhalation of Diesel Engine Exhaust Emissions (DEEE) – Carcinogenic Particulate Matter
Harm: Lung cancer (IARC Group 1), chronic obstructive pulmonary disease (COPD), cardiovascular disease, acute respiratory irritation. Long-term exposure exceeds HSE EH40/2005 WEL (0.05 mg/m³ elemental carbon).
4 × 5 = 20Engineering: Fit enclosed, pressurised ROPS/FOPS cabs with HEPA H13 filtration and positive pressure. Install LEV exhaust extraction in workshops (TH2 examined every 14 months). Administrative: Rotate operators to limit exposure <4 hrs/shift; prohibit idling >3 minutes. PPE: Issue FFP3 respirators for maintenance tasks. Air monitoring: Quarterly personal dosimetry for elemental carbon (MDHS 101).3 × 2 = 6
2. Dermal Contact & Aspiration of Diesel Fuel (ULSD) – Carcinogenic & Aspiration Toxicity
Harm: Aspiration pneumonitis (H304) if ingested/vomited; dermatitis, skin cancer from prolonged PAH exposure (H351); acute skin irritation (H315). Chronic exposure linked to leukaemia.
3 × 4 = 12Engineering: Use closed-loop fuel transfer systems with automatic shut-off nozzles; install drip trays and secondary containment (110% capacity, DSEAR 2002). Substitution: Specify ultra-low sulphur diesel (ULSD) to reduce PAH content. Administrative: Prohibit siphoning by mouth; enforce immediate skin washing. PPE: Nitrile gloves (BS EN 374-1 Type B), fuel-resistant boots (S3 FO). Health surveillance: Annual skin checks for operatives with >5 years exposure.2 × 2 = 4
3. Fire & Explosion Risk – Flammable Liquid (Class 3, H226) in Confined Spaces
Harm: Catastrophic fire/explosion causing fatalities, severe burns (>50% TBSA), structural collapse. Diesel vapour in confined spaces can reach Lower Explosive Limit (LEL ~0.6% v/v at 52°C flash point).
2 × 5 = 10DSEAR 2002 compliance: Conduct DSEAR risk assessment; classify zones (Zone 2 in transfer areas). Engineering: Bond and earth all transfer equipment; use ATEX-rated pumps and lighting in confined spaces. Administrative: Hot work permit system; continuous LEL monitoring (<10% LEL alarm threshold); enforce no-smoking zones (10 m radius). Emergency: Install CO₂/foam fire extinguishers (Class B) at 15 m intervals; train operatives in fire drills (6-monthly).1 × 4 = 4
4. Acute Inhalation of Diesel Vapour – CNS Depression & Respiratory Irritation (H336, STOT SE 3)
Harm: Dizziness, headache, nausea, loss of coordination (narcotic effects); mucous membrane irritation; exacerbation of asthma. Exposure >100 mg/m³ 8-hr TWA exceeds indicative WEL.
3 × 3 = 9Engineering: Conduct refuelling outdoors or in naturally ventilated areas (min. 5 air changes/hour). Install vapour recovery systems on bulk storage tanks. Administrative: Limit task duration to <30 minutes continuous; provide rest breaks in fresh air. Monitoring: Use portable PID (photoionisation detector) to measure total VOCs; trigger action at 50 mg/m³. PPE: Organic vapour respirator (A1P3) if ventilation inadequate.2 × 2 = 4
5. Environmental Contamination – Aquatic Toxicity & Soil Pollution (H411)
Harm: Diesel spills cause long-term aquatic ecosystem damage (toxic to fish, invertebrates); soil contamination triggers Environment Agency prosecution, remediation costs (£50k–£500k), and reputational damage.
4 × 3 = 12Engineering: Install double-skinned fuel tanks with leak detection; use spill pallets (110% capacity) under all storage. Construct impermeable hardstanding with oil interceptors (Class 1 full retention, EN 858). Administrative: Weekly visual inspections of tanks/pipework; maintain spill response plan (notify Environment Agency within 24 hrs for >10 L spills). Training: Annual refresher on spill kit deployment. Emergency: Deploy absorbent booms within 5 minutes; contract specialist remediation firm (pre-agreed SLA).2 × 2 = 4

3. Step-by-Step Safe Sequence of Operations & Hold-Points

1

Review SDS, Conduct Task-Specific COSHH Reg 6 Assessment & Atmospheric Testing

Pre-Task Planning & COSHH Review

Obtain current Safety Data Sheet (SDS) for diesel fuel (ULSD) and review CLP hazards (H226, H304, H315, H336, H351). Emphasise that the SDS is NOT a COSHH Regulation 6 assessment—conduct task-specific risk assessment using this template. Identify exposure routes (inhalation of DEEE, dermal contact, ingestion). For confined-space work, test atmosphere with calibrated 4-gas monitor (LEL <10%, O₂ 19.5–23.5%, CO <30 ppm, H₂S <5 ppm). Issue Permit to Work if required under DSEAR 2002. Confirm all operatives hold valid COSHH awareness training (refreshed annually).

Critical Hold-Point: ⚠️ STOP: Do NOT proceed if LEL >10%, O₂ outside safe range, or operatives lack FFP3 respirator fit-testing. A manufacturer's SDS does NOT replace the employer's legal duty under COSHH Reg 6 to assess task-specific risks and controls.
2

Implement Bonding/Earthing, LEV, and Lockout/Tagout (LOTO) for Plant Maintenance

Engineering Controls & Isolation (LOTO)

For refuelling: Connect bonding cable between fuel container and receiving tank to prevent static discharge (DSEAR 2002). Verify continuity <10 Ω with multimeter. For workshop maintenance on diesel engines: Isolate plant using LOTO procedure (lock energy sources, tag with operative's name, test zero energy). Activate LEV system and confirm face velocity ≥1 m/s at extraction hood (TH2 certificate valid). Position HEPA-filtered air mover to create negative pressure if working in enclosed engine bay. Erect barriers and 'No Smoking' signage (10 m exclusion zone).

Critical Hold-Point: ⚠️ HOLD POINT: Verify bonding continuity <10 Ω and LEV face velocity ≥1 m/s before fuel transfer or engine start. Do NOT bypass LOTO—uncontrolled engine start during maintenance can cause crush injuries and DEEE exposure.
3

Don Mandatory PPE (FFP3 Respirator, Nitrile Gloves, FO Boots, Eye Protection)

PPE Donning & Fit-Check

Perform FFP3 respirator fit-check: seal face, inhale sharply—mask should collapse against face. If beard or poor seal, use powered air-purifying respirator (PAPR) with TH3 hood. Don nitrile gloves (BS EN 374-1 Type B, min. 0.38 mm); inspect for tears. Wear fuel-resistant safety boots (S3 FO SRC) and safety spectacles (BS EN 166 Class 1, marking 3-4). Confirm all PPE is in-date and free from contamination. Operatives must not eat, drink, or smoke while wearing contaminated gloves.

Critical Hold-Point: ⚠️ CRITICAL: FFP3 respirators are single-shift disposable (NR). Reusing or sharing respirators invalidates protection and breaches COSHH Reg 7. Facial hair prevents effective seal—clean-shaven policy mandatory for tight-fitting RPE.
4

Execute Controlled Diesel Transfer Using Closed-Loop System & Spill Containment

Fuel Transfer & Refuelling Operations

Position drip tray or spill pallet (≥50 L capacity) under fill point. Insert nozzle fully into tank neck to minimise splashing and vapour release. Activate fuel pump; monitor flow rate and tank level to prevent overfilling (leave 5% ullage for thermal expansion). Maintain bonding throughout transfer. If manual pouring required, use funnel with fine mesh filter and pour slowly to avoid static generation. Do NOT siphon by mouth. Monitor for leaks; stop immediately if fuel odour intensifies or LEL alarm activates. Record volume transferred and inspect hoses/couplings for wear post-task.

Critical Hold-Point: ⚠️ STOP: If fuel spills >1 L, cease transfer immediately. Deploy spill kit, contain with absorbent booms, and ventilate area. Notify site supervisor and Environment Agency if spill enters drainage system or exceeds 10 L.
5

Operate Diesel Plant in Enclosed Cab or Well-Ventilated Area; Monitor DEEE Exposure

Engine Operation & Exposure Monitoring

Start engine outdoors or in workshop with LEV running and roller doors fully open (≥5 air changes/hour). If operating mobile plant, remain in enclosed ROPS/FOPS cab with HEPA filtration active and windows closed. Prohibit idling >3 minutes (switch off during breaks). For maintenance tasks requiring engine running (e.g., diagnostics), position exhaust extraction hose over tailpipe (sealed connection). Use portable CO monitor; evacuate if CO >30 ppm. Rotate operatives every 4 hours to limit cumulative DEEE exposure. Conduct quarterly personal air sampling (MDHS 101) to verify elemental carbon <0.05 mg/m³ TWA.

Critical Hold-Point: ⚠️ DANGER: DEEE is an IARC Group 1 carcinogen. NEVER run diesel engines in unventilated confined spaces (e.g., shipping containers, basements)—fatal CO poisoning can occur within 10 minutes. Enforce zero-tolerance policy.
6

Decontaminate PPE, Dispose of Contaminated Waste, and Update COSHH Assessment

Decontamination, Waste Disposal & Post-Task Review

Remove gloves inside-out and dispose in hazardous waste bin (EWC 15 02 02*). Wash hands and forearms with soap and water (do NOT use solvents or abrasives). Dispose of used FFP3 respirators as general waste (unless visibly contaminated with diesel). Place diesel-soaked absorbents in UN-approved drums (EWC 15 02 02*) and arrange collection by licensed carrier (Duty of Care transfer note). Clean tools with degreaser in well-ventilated area. Inspect skin for irritation; report to occupational health if dermatitis suspected. Review COSHH assessment annually or after incident/near-miss; update controls if new plant or fuel grades introduced.

Critical Hold-Point: ⚠️ LEGAL DUTY: Contaminated PPE and absorbents are hazardous waste under Environmental Protection Act 1990. Illegal disposal (e.g., general skip, drain) incurs unlimited fines and director disqualification. Retain Duty of Care paperwork for 2 years.

Emergency Rescue, First Aid & Spill Protocol

**EMERGENCY RESPONSE & FIRST AID (COSHH Reg 8, INDG286):** **Inhalation of Diesel Vapour or DEEE:** 1. Remove casualty to fresh air immediately; loosen tight clothing. 2. If unconscious but breathing, place in recovery position; monitor airway. 3. If not breathing, commence CPR (trained first aiders only) and call 999. 4. Administer high-flow oxygen (15 L/min via non-rebreather mask) if available and trained. 5. Inform paramedics of DEEE/diesel vapour exposure and provide SDS. 6. Do NOT induce vomiting. Seek medical attention for all symptomatic cases (headache, dizziness, chest tightness). **Skin Contact:** 1. Remove contaminated clothing immediately (cut off if necessary to avoid head contact). 2. Wash affected area with copious soap and lukewarm water for ≥15 minutes. 3. Do NOT use solvents, abrasives, or barrier creams post-exposure. 4. Cover area with clean, dry dressing if skin broken or blistered. 5. Seek medical attention if irritation persists >1 hour or area >10 cm². Inform doctor of H304 aspiration hazard. **Eye Contact:** 1. Irrigate eyes with clean water or sterile saline for ≥15 minutes, holding eyelids open. 2. Remove contact lenses after initial rinse if easily removable. 3. Seek immediate medical attention (A&E or optometrist); provide SDS. **Ingestion (Aspiration Hazard H304):** 1. Do NOT induce vomiting—aspiration of diesel into lungs can be fatal. 2. Rinse mouth with water; do NOT give anything by mouth if unconscious. 3. Call 999 immediately and inform of H304 aspiration toxicity. 4. Monitor for respiratory distress (coughing, choking, cyanosis); administer oxygen if trained. **Fire/Explosion:** 1. Activate fire alarm; evacuate to assembly point (min. 50 m upwind). 2. Call 999 and inform of Class 3 flammable liquid (UN 1202) and volume stored. 3. If safe, isolate fuel supply and close fire doors/shutters. 4. Use CO₂, foam, or dry powder extinguishers on small fires (<1 m²). Do NOT use water jet (spreads fire). 5. Do NOT re-enter until Fire Service declares safe and atmosphere tested. **Large Spill (>10 L):** 1. Evacuate non-essential personnel; establish 10 m cordon. 2. Eliminate ignition sources (switch off engines, electrics; no mobile phones in hazard zone). 3. Notify Environment Agency Incident Hotline (0800 807060) within 24 hours. 4. Deploy spill kit: contain with absorbent booms, cover with pads, avoid washing into drains. 5. Ventilate area and monitor LEL continuously. Engage specialist contractor if >200 L or enters watercourse. **Reporting:** - Report all DEEE-related ill-health (respiratory symptoms, suspected cancer) to HSE under RIDDOR 2013 (occupational disease). - Maintain accident book (BI 510) and investigate near-misses (e.g., LEL alarms, spills) within 48 hours. - Provide SDS and this COSHH assessment to emergency services and occupational health.

4. UK HSE & PQQ Compliance FAQs: COSHH Assessment for Diesel Fuel (ULSD) & Diesel Engine Exhaust Emissions (DEEE) UK

5. Operative Toolbox Talk & Competent Person Sign-Off Register

Operative / Supervisor Name Trade / Role & CSCS No. Signature Date & Time
1. (Site Supervisor):     
2.     
3.     
4.     

Automate UK Safety Documentation with SafeSequence®

Need site-specific compliance documentation instead of a static template? Explore the core SafeSequence® UK software modules hosted in AWS London (eu-west-2):

45s Voice RAMS & COSHH Dictate site tasks or select CLP diamonds to generate UK 5×5 RAMS & Reg 6 COSHH PDFs. PCI Tender-to-RAMS Studio Upload 300-page Principal Contractor PCI PDFs for [Page X] cited RAMS & PAS 91 answers. Enterprise Visual SOPs Turn shop-floor POV walkthrough video into GDPR-redacted Visual SOPs, 6S OPLs & CAPAs. HSE Consultant Vaults Multi-client white-label RAMS, Visual SOP & COSHH software for CMIOSH consultants.

Related UK Safety & Tender Templates