Under RICS NRM2/SMM7 Trade Pricing, HASAWA 1974 s.2, CDM 2015 Reg.13, PUWER 1998 Reg.4, and VATA 1994 s.55A (CIS Domestic Reverse Charge), UK Facilities Management (FM) contractors must publish transparent reactive callout rate cards detailing emergency response times, hourly labour rates, materials mark-up, plant hire, and statutory 20% VAT or CIS deduction status. This audit-grade template integrates a 2026 UK trade Bill of Quantities (BoQ) with 5×5 risk-scored RAMS, enabling Main Contractors and Client POs to lock commercial terms whilst automatically unlocking pre-staged method statements for plumbing, electrical, HVAC, fabric, and security callouts. Each line item specifies CIS treatment, BS EN PPE mandates, PUWER isolation protocols, and residual risk ≤6 to satisfy CDM Principal Designer gateway reviews and insurance underwriter due diligence across multi-site FM frameworks.
Need to price this scope for a client buyer? Dictate your scope in the SafeSequence Voice-to-Quote Studio to compile a custom BoQ, auto-fill your blank .docx letterhead, and unlock the matching 5×5 RAMS below at £0 extra credit cost when the PO lands.
| Code | Trade Item & Specification | Category | Qty / Unit | Unit Rate | Net Total |
|---|---|---|---|---|---|
| MAT-FM-001 | Emergency plumbing consumables pack: 15mm/22mm copper fittings, PTFE tape, flux, solder, compression fittings, isolation valves (WRAS approved). CIS Reverse Charge applies (VATA 1994 s.55A) – zero-rated VAT on invoice; client accounts for VAT. | Materials | 1 No. callout pack | £85.00 | £85.00 |
| MAT-FM-002 | Electrical consumables: MCBs (6A–32A Type B), RCBOs, 2.5mm²/1.5mm² T&E cable, junction boxes, cable clips, earth sleeving (BS 7671:2018 compliant). CIS Reverse Charge applies – zero-rated VAT. | Materials | 1 No. callout pack | £120.00 | £120.00 |
| PLT-FM-003 | Mobile scaffold tower hire (3.2m platform height, BS EN 1004:2020 compliant) for ceiling/high-level reactive access. Standard 20% VAT applies (plant hire outside CIS scope). | Plant | 1 Week hire | £95.00 | £95.00 |
| LAB-FM-004 | JIB Approved Electrician (Gold Card) – Emergency callout labour (first 4 hours, including travel). CIS 20% deduction applies if subcontractor; Standard 20% VAT if direct employment PAYE. | Labour | 4 Hours | £58.00 | £232.00 |
| Identified Hazard & Harm | Initial Risk (L×S) | Mandatory Engineering, Isolation & Procedural Controls | Residual Risk |
|---|---|---|---|
| 1. Electrical shock or arc flash from live circuits during emergency fault-finding without isolation Harm: Electrocution, cardiac arrest, severe burns, or arc-flash injuries; potential fatality. | 4 × 5 = 20 | Enforce BS 7671:2018+A2:2022 safe isolation procedure (isolate, lock-off, test, re-test). Use calibrated voltage indicator and insulated tools (VDE 1000V). Permit-to-Work for live testing. JIB Gold Card electrician only. Portable RCD protection on all temporary supplies. Arc-rated PPE if live work unavoidable (HSE Guidance HSG230). | 2 × 3 = 6 |
| 2. Manual handling of heavy plant components (pumps, motors, AHUs) causing musculoskeletal injury Harm: Back strain, herniated discs, shoulder/knee injuries; long-term disability. | 4 × 3 = 12 | Manual Handling Operations Regulations 1992: risk assessment mandatory. Use mechanical aids (sack trucks, pallet trucks, hoists). Two-person lift for items >25kg. Ergonomic lifting training (kinetic handling). Pre-task dynamic risk assessment. Ensure clear access routes and adequate lighting. | 2 × 2 = 4 |
| 3. Working at height (ladders, mobile towers) for ceiling/roof plant access without fall protection Harm: Falls from height causing fractures, head injuries, spinal trauma, or fatality. | 3 × 5 = 15 | Work at Height Regulations 2005: avoid work at height where possible; use mobile scaffold tower (BS EN 1004:2020) with guardrails and toe-boards. Ladder use only for light, short-duration tasks (<30 min, 3-point contact). Harness and anchor points for roof access. PASMA or IPAF training verified. Pre-use tower inspection checklist. | 2 × 3 = 6 |
| 4. Confined space entry (plant rooms, voids, risers) with inadequate ventilation or oxygen depletion Harm: Asphyxiation, toxic gas exposure, unconsciousness, or death. | 3 × 5 = 15 | Confined Spaces Regulations 1997: formal risk assessment and Permit-to-Work. Atmospheric testing (O₂, CO, H₂S, LEL) before entry and continuously during work. Forced ventilation. Trained confined-space operative with standby person and rescue plan. Emergency retrieval equipment. Communication (radio/phone). Escape breathing apparatus (EBA) available. | 2 × 3 = 6 |
| 5. Exposure to hazardous substances (refrigerants, cleaning chemicals, asbestos dust) without COSHH assessment Harm: Respiratory sensitization, chemical burns, long-term lung disease (asbestosis, mesothelioma). | 3 × 4 = 12 | COSHH Regulations 2002 (as amended): obtain SDS for all substances. F-Gas Regulation (EU) 517/2014 (UK retained): only F-Gas certified engineers handle refrigerants. Asbestos survey (CAR 2012) mandatory before intrusive works; licensed removal if ACMs present. RPE (FFP3 or supplied-air) for dust/vapour. Local exhaust ventilation (LEV). Spill kits and eyewash stations. Health surveillance for sensitizers. | 2 × 2 = 4 |
Client issues Purchase Order referencing this Rate Card. Contractor confirms acceptance, callout SLA (e.g. 2-hour emergency response), and CIS/VAT treatment per VATA 1994 s.55A. Upload signed PO and insurance certificates (Public Liability £5M, Employers' Liability £10M) to client portal. Verify operative competence: JIB Gold Card (electrical), Gas Safe (gas), PASMA/IPAF (access), confined space certification as applicable.
Log callout time and nature of fault (plumbing leak, electrical trip, HVAC failure, etc.). Operative attends within SLA window. Complete site-specific induction (fire exits, first-aiders, permit systems, asbestos register review). Sign in via visitor management system. Collect site-specific risk information (drawings, previous maintenance records, known hazards). Don mandatory PPE (BS EN ISO 20345 boots, BS EN 388 gloves, BS EN 166 eyewear, BS EN ISO 20471 hi-vis).
Identify and isolate relevant service: electrical (BS 7671 safe isolation: isolate, lock, test, re-test with calibrated voltage indicator); mechanical (PUWER 1998: isolate motor/pump, LOTO, dissipate stored energy); water (close isolation valves, drain down if required); gas (Gas Safe engineer only, purge and cap if necessary). Apply LOTO padlocks and 'Danger – Do Not Operate' tags. Verify isolation with appropriate test equipment. Photograph isolation points and LOTO tags for audit trail.
Diagnose root cause using calibrated test equipment (multimeter, pressure gauge, thermometer, etc.). Execute repair using materials from BoQ (MAT-FM-001/002) or client-approved equivalents. If working at height, erect mobile tower per PASMA (BS EN 1004:2020) or use secured ladder (3-point contact, 1:4 angle, tied). If confined space, implement Permit-to-Work and atmospheric monitoring. Maintain two-way communication with site contact. Document all work photographically (before, during, after). Update client via real-time app/portal if available.
Complete functional testing: electrical circuits (insulation resistance, continuity, RCD trip time per BS 7671); plumbing (pressure test, flow test, leak check); HVAC (airflow, temperature differential, control sequence). Remove LOTO devices in reverse order. Re-energise services under controlled conditions. Verify normal operation. Reinstate any fabric (ceiling tiles, access panels, trunking lids). Clean work area and remove waste (Duty of Care: Environmental Protection Act 1990 s.34). Hand over to client representative with verbal briefing.
Issue Completion Certificate detailing: works executed, materials used (BoQ references), test results, photographs, operative signatures, client sign-off. Attach this 5×5 RAMS, COSHH SDS (if substances used), and calibration certificates (test equipment). Generate invoice per Rate Card: itemise labour hours (LAB-FM-004), materials (MAT-FM-001/002), plant hire (PLT-FM-003). Apply CIS Reverse Charge (zero-rated VAT, client self-accounts) or Standard 20% VAT as applicable. Submit via client portal within 48 hours. Retain records for 6 years (HMRC, CDM 2015 Reg.4(9)).
**Emergency Contact:** Site First Aider and nearest A&E location confirmed during site induction. **Electrical Shock:** Do NOT touch casualty if still in contact with live conductor. Isolate supply immediately. Call 999. If breathing, place in recovery position; if not breathing, commence CPR (30 compressions:2 breaths) until paramedics arrive. **Burns (Electrical/Chemical):** Cool burn under running water for 20 minutes. Remove contaminated clothing (not if stuck to skin). Cover with sterile non-adhesive dressing. Call 999 for severe burns (>5% body area or face/hands). **Falls from Height:** Do not move casualty if spinal injury suspected. Call 999. Keep warm and monitor consciousness. **Confined Space Rescue:** Do NOT enter without BA and rescue training. Raise alarm, call 999, initiate emergency retrieval using pre-positioned equipment. **Chemical Exposure:** Consult SDS emergency section. Irrigate eyes/skin for 15 minutes. If inhaled, move to fresh air. Call 999 or NHS 111 and quote substance name. **All Incidents:** Report immediately to client Duty Holder and HSE under RIDDOR 2013 if: fatality, major injury (fracture, amputation, unconsciousness), over-7-day injury, dangerous occurrence (electrical short-circuit causing fire, structural collapse, etc.). Preserve scene for investigation.
Yes. Under VATA 1994 s.55A (effective 1 March 2021), construction services—including FM reactive maintenance, repairs, and installations—are subject to the CIS Domestic Reverse Charge if both contractor and client are CIS-registered. The contractor zero-rates VAT on the invoice, and the client self-accounts for VAT via their VAT return. Standard 20% VAT applies to plant hire (outside CIS scope) and to non-CIS clients (e.g. end-user occupiers). Always verify client CIS status and document on the invoice to avoid HMRC penalties.
The operative must hold a JIB Gold Card (Approved Electrician) or equivalent (e.g. ECS Gold Card, NVQ Level 3 Electrical Installation), demonstrating competence in BS 7671:2018+A2:2022 (IET Wiring Regulations). Additionally, they must have completed 18th Edition Wiring Regulations training, Inspection & Testing (2391 or equivalent), and CDM 2015 site safety awareness. For live working (if unavoidable), they require specific authorisation, arc-rated PPE, and a Permit-to-Work. Employers must verify and record competence per CDM 2015 Reg.9 and retain training certificates for audit.
Benchmark 2026 UK rates: JIB Approved Electrician £55–65/hour; plumber £50–60/hour; HVAC engineer £60–70/hour. Add 15–25% materials mark-up (industry standard per RICS NRM2). Include plant hire at cost +10%. Factor in insurance (Public Liability £5M ~£800/year; Employers' Liability £10M ~£600/year), RAMS preparation (1–2 hours QS/HSE time per template), and callout vehicle/fuel (~£0.45/mile HMRC rate). Offer tiered SLAs (e.g. 2-hour emergency, 4-hour urgent, next-day routine) with premium rates for out-of-hours (+50% nights, +100% weekends/bank holidays). Transparently itemise CIS/VAT treatment and lock rates for 12 months to de-risk client budgets and score highly in MEAT (Most Economically Advantageous Tender) evaluations.
| Operative / Supervisor Name | Trade / Role & CSCS No. | Signature | Date & Time |
|---|---|---|---|
| 1. (Site Supervisor): | |||
| 2. | |||
| 3. | |||
| 4. |
Need a priced commercial quote or site-specific compliance pack instead of a static template? Explore the live SafeSequence® UK studios hosted in AWS London (eu-west-2):