Under COSHH Regulations 2002 (as amended), REACH Diisocyanate Training Mandate (Regulation EU 2020/1149), and EH40/2005 Workplace Exposure Limits, Sika Sikaflex-11 FC+ & EBT polyurethane adhesive sealant (GHS07, H317 Skin Sensitiser Category 1) requires mandatory respiratory protection, skin contact prevention, local exhaust ventilation (LEV), and documented diisocyanate competency training to reduce dermal sensitisation and respiratory exposure risks from High (15-20) to Low (3-4) through engineering controls and strict isolation protocols.
| Identified Hazard & Harm | Initial Risk (L×S) | Mandatory Engineering, Isolation & Procedural Controls | Residual Risk |
|---|---|---|---|
| 1. Dermal sensitisation from polymeric MDI (diphenylmethane diisocyanate) skin contact Harm: Allergic contact dermatitis, chronic skin sensitisation, occupational asthma trigger, permanent sensitisation requiring medical surveillance and job restriction | 4 × 4 = 16 | Eliminate skin contact: nitrile gloves BS EN ISO 374-1:2016 (>0.38mm, >480 min breakthrough). Pre-task skin checks. Immediate washing facilities within 5m. Barrier creams prohibited (HSG97). COSHH assessment review every 12 months. Occupational health surveillance (skin inspections) for all exposed workers. Documented glove change protocol every 2 hours or on visible contamination. | 2 × 2 = 4 |
| 2. Inhalation of MDI aerosol/vapour exceeding EH40/2005 WEL (0.02 mg/m³ 8-hour TWA) Harm: Respiratory sensitisation, occupational asthma, bronchospasm, chronic obstructive pulmonary disease (COPD), permanent respiratory impairment requiring medical removal | 4 × 5 = 20 | Engineering control hierarchy: LEV system (HSG258) with 0.5 m/s minimum capture velocity at source. LEV thorough examination and test (TExT) every 14 months by competent person (COSHH Regulation 9). Respiratory protection: BS EN 140 half-mask with P3+A2 filters where LEV insufficient. Quantitative fit-testing (QNFT) annually. Personal air monitoring (MDHS14/4) for initial exposure assessment and every 24 months. Restrict work to <2 hours without break. Prohibit eating/drinking/smoking in work area. | 2 × 2 = 4 |
| 3. Eye contact with uncured polyurethane sealant (H319 serious eye irritation) Harm: Corneal abrasion, chemical conjunctivitis, temporary vision impairment, secondary infection risk, potential permanent eye damage if not irrigated immediately | 3 × 3 = 9 | Mandatory eye protection: BS EN 166:2001 safety spectacles (1.F.3) with side shields or full-face visor during dispensing and application. Emergency eyewash station (BS EN 15154-2:2006) within 10 seconds travel time. Pre-task briefing on emergency eye irrigation procedure (15 minutes continuous flush). Prohibit contact lens wear during application. Annual eye examination for exposed workers. | 2 × 2 = 4 |
| 4. Confined space application without adequate ventilation (oxygen depletion, vapour accumulation) Harm: Asphyxiation, acute respiratory distress, loss of consciousness, fatal exposure to isocyanate vapours, explosive atmosphere formation with ignition sources | 3 × 5 = 15 | Confined Space Regulations 1997 compliance: Permit-to-Work system mandatory. Pre-entry atmospheric testing (O₂ >19.5%, LEL <10%, MDI <0.02 mg/m³). Forced mechanical ventilation (minimum 6 air changes/hour). Continuous gas monitoring with audible alarms. Standby person and rescue plan. Emergency retrieval equipment. Prohibit lone working. Full-face respirator (BS EN 136) with airline supply for entries >30 minutes. | 1 × 3 = 3 |
| 5. Lack of REACH-mandated diisocyanate training (Regulation EU 2020/1149) Harm: Non-compliance prosecution, enforcement notice, work stoppage, uncontrolled exposure incidents, worker sensitisation due to inadequate control knowledge, corporate liability | 5 × 3 = 15 | Mandatory documented diisocyanate training (REACH Regulation EU 2020/1149) for all users before first exposure. Training must cover: health hazards, safe handling, PPE selection/use, emergency procedures, exposure monitoring. Refresher training every 5 years minimum. Training records retained for 5 years post-employment. Competency assessment and sign-off by CMIOSH or Occupational Hygienist. Prohibit untrained personnel from handling product. Supplier training certificates verified and audited annually. | 2 × 2 = 4 |
Verify all operatives hold valid REACH diisocyanate training certificates (Regulation EU 2020/1149) dated within 5 years. Review site-specific COSHH assessment and Method Statement. Inspect LEV system: check airflow indicator (minimum 0.5 m/s capture velocity), verify TExT certificate valid (within 14 months), test audible alarm function. Confirm emergency eyewash station operational (15-second flow test). Establish exclusion zone (3m radius) with barrier tape and signage (GHS07 pictogram, 'Respiratory Sensitiser – PPE Mandatory').
Conduct pre-task skin inspection: check hands, forearms, and face for cuts, abrasions, or dermatitis (record findings). Don Type 5/6 coveralls (BS EN ISO 13982-1/BS EN 13034). Don nitrile gloves (BS EN ISO 374-1:2016, >0.38mm thickness) ensuring cuffs overlap coverall sleeves by minimum 100mm. Don safety spectacles (BS EN 166:2001) or full-face visor. If LEV inadequate or confined space work, don half-mask respirator (BS EN 140) with P3+A2 filters and perform positive/negative pressure fit-check. Record PPE issue and fit-check on task permit.
Clean substrate with isopropanol wipes (ensure adequate ventilation during solvent use). Allow surface to dry completely (typically 5-10 minutes). Position LEV capture hood within 300mm of application point, angled to capture rising vapours. Load Sikaflex-11 FC+ cartridge into application gun, ensuring secure seal. Puncture cartridge seal and attach mixing nozzle (if two-part EBT variant). Purge first 50mm of sealant onto disposable cloth to ensure homogeneous mix. Apply masking tape to define joint edges.
Dispense sealant in continuous bead at controlled rate (typically 100-150mm/minute for 10mm joint). Maintain gun nozzle 5-10mm from substrate. Tool joint immediately using wetted spatula or profiling tool (wet with soapy water, not solvent). Remove masking tape within 10 minutes of application while sealant still uncured. Avoid hand contact with uncured sealant – use tools only. Limit continuous application to 2 hours maximum, then take 15-minute break in fresh air area. Dispose of used cartridges and contaminated materials in sealed polyethylene bags labelled 'Isocyanate Waste – H317 Sensitiser'.
Maintain LEV operation or natural ventilation for minimum 24 hours post-application (Sikaflex-11 FC+ cures by moisture reaction, releasing trace MDI vapour). Maintain exclusion zone signage and barriers until sealant fully cured (typically 3-7 days depending on temperature/humidity). Prohibit grinding, cutting, or hot work on cured sealant for 7 days. Monitor work area with portable MDI detector if available (target <0.02 mg/m³). Record application date, batch number, and cure conditions in site diary.
Remove PPE in controlled sequence to avoid self-contamination: remove outer gloves (turn inside-out), remove coveralls (roll inwards), remove eye protection, remove respirator (if worn), remove inner gloves last (turn inside-out). Dispose of all single-use PPE in sealed polyethylene bags labelled 'Hazardous Waste – Isocyanate Contaminated – EWC 15 02 02*'. Clean reusable tools with isopropanol in well-ventilated area (LEV or outdoors). Wash hands and forearms thoroughly with soap and water. Conduct post-task skin inspection and record findings. Store unused cartridges in original packaging in cool, dry location (<25°C) away from moisture sources.
**SKIN CONTACT:** Immediately remove contaminated clothing and footwear. Wash affected area with soap and copious running water for minimum 15 minutes. Do NOT use solvents on skin. Seek medical attention if irritation, rash, or sensitisation symptoms develop. Report exposure to Occupational Health within 1 hour for surveillance record. **EYE CONTACT:** Immediately irrigate eyes with clean water or eyewash solution for minimum 15 minutes, holding eyelids open. Remove contact lenses if present and easy to do. Seek immediate medical attention – transport to A&E or call 999 if severe pain or vision impairment. **INHALATION:** Remove casualty to fresh air immediately. If breathing is difficult, administer oxygen if trained and equipment available. If breathing stops, commence CPR. Seek immediate medical attention – call 999. Inform paramedics of isocyanate exposure (MDI). Monitor for delayed respiratory symptoms (up to 24 hours post-exposure). **INGESTION:** Do NOT induce vomiting. Rinse mouth thoroughly with water. Give small amounts of water to drink if conscious. Seek immediate medical attention – call 999 or NHS 111. **SPILLAGE:** Evacuate area and establish 5m exclusion zone. Ensure adequate ventilation. Don full PPE (nitrile gloves, respirator with P3+A2 filters, coveralls, eye protection). Absorb liquid with inert material (vermiculite, sand). Place contaminated absorbent in sealed polyethylene bags labelled 'Hazardous Waste – Isocyanate'. Ventilate area for minimum 30 minutes post-cleanup. Dispose via licensed hazardous waste carrier (EWC 08 04 09*). **FIRE:** Sikaflex-11 FC+ is combustible. Thermal decomposition releases toxic isocyanate vapours and nitrogen oxides. Evacuate area. Use water spray, foam, dry powder, or CO₂ extinguishers. Firefighters must wear SCBA and full chemical-protective clothing. Contain contaminated firewater – do not allow to enter drains or watercourses (environmental hazard).
No – a toolbox talk is not sufficient and does not meet the legal requirement. REACH Regulation (EU) 2020/1149, retained in UK law, mandates documented, structured diisocyanate training delivered by a competent provider before any worker handles products containing >0.1% diisocyanate (which Sikaflex-11 FC+ contains as polymeric MDI). The training must cover specific modules on health effects, exposure routes, safe handling, PPE, and emergency procedures, and must be refreshed every 5 years. HSE can prosecute for non-compliance, and your liability insurance may be invalidated if an untrained worker develops occupational asthma or dermatitis. Use an accredited training provider (e.g., BOHS, Sika's own training portal, or industry-recognised e-learning platforms) and retain certificates for 5 years post-employment.
You can proceed using respiratory protection as an interim control, but only under strict conditions and with documented risk assessment justification. COSHH Regulation 7 establishes a hierarchy: engineering controls (LEV) must be used in preference to PPE (respirators). However, if LEV failure is temporary and the work is urgent, you may use half-mask or full-face respirators with combined P3 particulate and A2 organic vapour filters (BS EN 140, BS EN 143, BS EN 14387), provided: (1) all users are face-fit tested within the last 12 months (quantitative fit-testing preferred); (2) you limit work duration to maximum 2 hours per shift with 15-minute fresh-air breaks; (3) you increase air monitoring (personal sampling) to verify exposure remains below 0.02 mg/m³ WEL; (4) you document the decision and interim controls in your COSHH assessment and Method Statement. Do NOT use respirators as a long-term substitute for LEV – HSE inspectors will issue enforcement notices. Get the LEV repaired and TExT-certified as soon as possible.
Yes – you should be very concerned, and the worker must be referred to Occupational Health immediately before any further isocyanate exposure. The rash is a strong indicator of isocyanate sensitisation (allergic contact dermatitis), which is irreversible and can progress to severe systemic reactions or occupational asthma with repeated exposure. Under COSHH Regulation 11, you must provide health surveillance for workers exposed to respiratory sensitisers and skin sensitisers. The worker should be medically assessed by an occupational health physician or nurse, who will determine fitness to continue isocyanate work. In many cases, sensitised workers must be permanently removed from isocyanate exposure and redeployed to alternative duties – continuing exposure can trigger life-threatening anaphylaxis or chronic respiratory disease. Document the incident in your RIDDOR records (if the worker has been off work for >7 days or diagnosed with occupational disease, it is reportable under RIDDOR 2013). Review your COSHH controls – the sensitisation indicates a failure in skin contact prevention (inadequate gloves, poor hygiene, or lack of training). This is a serious compliance and duty-of-care issue.
Competent Person & Operative Declaration: By signing below, the Site Supervisor confirms this assessment has been adapted and verified for actual site conditions, and operatives confirm they have attended the pre-start Toolbox Talk for Sika Sikaflex-11 FC+ & EBT Polyurethane Adhesive Sealant and will follow the safe system of work.
| Operative / Supervisor Name | Trade / Role & CSCS No. | Signature | Date & Time |
|---|---|---|---|
| 1. (Site Supervisor): | |||
| 2. | |||
| 3. | |||
| 4. | |||
| 5. | |||
| 6. |