SafeSequence › UK Safety Template Library › COSHH & Chemical Safety › Sodium Hypochlorite (14-15% Available Chlorine) Industrial Bleach
Verified UK COSHH Standard • COSHH & Chemical Safety

Sodium Hypochlorite (14-15% Available Chlorine) Industrial Bleach (COSHH Template & 5x5 Risk Assessment)

This COSHH assessment addresses the safe handling, storage, and use of Sodium Hypochlorite solution (14-15% available chlorine) in industrial settings. Sodium Hypochlorite is a corrosive oxidising liquid classified under CLP Regulation with hazard pictograms GHS05 (Corrosive) and GHS09 (Environmental Hazard). The substance presents significant risks including skin/eye corrosion, respiratory irritation, and environmental harm if released. This document complies with COSHH Regulations 2002 (as amended), HSE EH40/2005 Workplace Exposure Limits, and CLP Regulation requirements. Control measures include engineering controls (local exhaust ventilation, closed transfer systems), administrative controls (permit-to-work, competency training), and mandatory PPE. The assessment identifies critical hazards with initial risk scores and demonstrates risk reduction through implementation of hierarchy of controls. All personnel handling this substance must be trained in COSHH principles, emergency response, and spillage procedures. Regular exposure monitoring, health surveillance, and COSHH assessment reviews (minimum annually or following incident/process change) are mandatory.

Statutory FrameworkCOSHH Regulations 2002, HSE EH40/2005 Workplace Exposure Limits, CLP Regulation (GHS05, GHS09)
ClassificationUN Number: UN1791 (Hypochlorite solution). CLP/GHS Classification: Skin Corrosion Category 1A (H314 - Causes severe skin burns and eye damage), Aquatic Acute Category 1 (H400 - Very toxic to aquatic life). Hazard Pictograms: GHS05 (Corrosion), GHS09 (Environment). Signal Word: DANGER. Precautionary Statements: P280 (Wear protective gloves/protective clothing/eye protection/face protection), P305+P351+P338 (IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses if present and easy to do. Continue rinsing), P310 (Immediately call a POISON CENTER or doctor/physician), P273 (Avoid release to the environment), P501 (Dispose of contents/container in accordance with local/national regulations). WEL (Workplace Exposure Limit): 0.5 ppm (1.5 mg/m³) 15-minute STEL for chlorine gas (potential decomposition product). Storage: Store in original container in cool, dry, well-ventilated area away from acids, ammonia, and organic materials. Incompatible with acids (generates toxic chlorine gas).
Required Plant / KitChemical-resistant transfer pump with grounding capability (ATEX-rated for hazardous areas) • Sealed dosing system with automatic shut-off and flow control • Local Exhaust Ventilation (LEV) system with minimum 10 air changes per hour (LEV examination certificate required every 14 months) • Emergency eyewash station (BS EN 15154-2 compliant) and deluge shower (BS EN 15154-1) • Spill containment kit including neutralising agent (sodium thiosulphate), absorbent pads, disposal bags, and hazard tape
Review Cycle12 Months / Post-Incident
Instant AI Customization or Free Blank Word (.doc) Download

Need this COSHH customized with your Company Name, Site Postcode & Nearest A&E Hospital?

Dictate your site specifics on your phone in 45 seconds to auto-compile a signed PDF—or download our free blank Word (.doc) shell below.

Auto-Fill via Voice / CLP (45s)

2. 5×5 Hazard Risk Assessment Matrix (HASAWA 1974 / MHSWR 1999)

Identified Hazard & Harm Initial Risk (L×S) Mandatory Engineering, Isolation & Procedural Controls Residual Risk
1. Skin and eye corrosion from direct contact with 14-15% Sodium Hypochlorite solution
Harm: Severe chemical burns, permanent scarring, eye damage leading to blindness, long-term disability
4 × 5 = 20 Engineering: Closed transfer systems with sealed connections to eliminate manual handling. Administrative: Permit-to-work system for all transfer operations, two-person rule for decanting. PPE: Mandatory chemical-resistant gloves (BS EN ISO 374-1 Type A), full-face shield (BS EN 166), Type 4 coveralls. Emergency eyewash/deluge shower within 10 seconds travel time (BS EN 15154). Pre-task risk briefing mandatory. 2 × 4 = 8
2. Inhalation of chlorine gas from decomposition or mixing with incompatible substances (acids, ammonia)
Harm: Acute respiratory distress, pulmonary oedema, chemical pneumonitis, chronic respiratory impairment
3 × 5 = 15 Engineering: Local Exhaust Ventilation (LEV) at all transfer/dosing points with minimum 10 ACH, LEV examination every 14 months (COSHH Regulation 9). Segregated storage with physical barriers from incompatibles. Gas detection system with audible/visual alarms set at 0.3 ppm (60% of WEL). Administrative: LOTO procedures for maintenance, hot work permit system. Atmospheric testing before entry to confined spaces. Respiratory Protective Equipment (RPE) available: Full-face mask with ABEK-P3 filter (BS EN 14387) for emergency response. 2 × 3 = 6
3. Environmental release to watercourses or drainage systems causing aquatic toxicity
Harm: Prosecution under Environmental Protection Act 1990, fish kills, ecosystem damage, unlimited fines, director liability
3 × 4 = 12 Engineering: Secondary containment (110% of largest container volume) with impermeable bunding, sealed drainage with interceptor valve. Automatic leak detection system. Administrative: Environmental permit compliance, spill response plan with Environment Agency notification protocol (0800 807060). Weekly bund integrity inspections documented. Neutralisation agent (sodium thiosulphate) immediately available. Staff trained in emergency spill procedures (IOSH Managing Environmental Responsibilities or equivalent). 1 × 3 = 3
4. Exothermic reaction and toxic gas generation from accidental mixing with acids or organic materials
Harm: Violent boiling, container rupture, chlorine gas release, multiple casualties, site evacuation
2 × 5 = 10 Engineering: Dedicated storage area with physical separation (minimum 3 metres) from incompatibles, clearly marked segregation zones. Separate transfer equipment colour-coded and labelled. Temperature monitoring with high-temperature alarm. Administrative: Incompatibility matrix displayed at storage location. Delivery acceptance procedure verifying correct substance before unloading. LOTO during maintenance. Competency assessment for all handlers (minimum NVQ Level 2 in Chemical Operations or equivalent). Prohibition of simultaneous handling of incompatible substances. 1 × 4 = 4
5. Manual handling injuries during container movement (25kg containers typical)
Harm: Musculoskeletal disorders, back injury, dropped containers causing spillage and secondary chemical exposure
4 × 3 = 12 Engineering: Mechanical handling aids mandatory - drum trolleys, pallet trucks, or overhead hoist systems. Storage at waist height (750-1200mm) to eliminate lifting from floor. Automated dosing systems to eliminate manual decanting. Administrative: Manual Handling Operations Regulations 1992 assessment completed, maximum single-person lift 10kg for chemical containers. Team lifting procedures for containers >10kg. Designated handling zones with clear access routes. Training in safe manual handling techniques (refresher every 3 years). Supervision during all container movements. 2 × 2 = 4

3. Step-by-Step Safe Sequence of Operations & Hold-Points

1

Pre-Task Risk Assessment and Area Preparation

Preparation

Complete permit-to-work documentation and conduct pre-task briefing with all personnel. Verify LEV system operational (check airflow indicator and test alarm functions). Confirm emergency eyewash/deluge shower functional (weekly test record checked). Establish exclusion zone with barrier tape (minimum 3-metre radius). Verify spill kit location and contents. Check weather conditions if outdoor work - postpone if high winds (>20 mph) or rain forecast. Confirm communication method (radio/mobile) and emergency contact numbers displayed. Ensure minimum two competent persons present.

Critical Hold-Point: STOP - Do not proceed unless LEV system is operational and emergency eyewash/shower tested within last 7 days. Verify all personnel have current COSHH training (records checked). Lone working is strictly prohibited.
2

PPE Donning and Inspection

Preparation

Inspect all PPE for damage, degradation, or contamination before use. Check gloves for punctures (inflate and squeeze test), verify face shield has no cracks or scratches affecting visibility. Don PPE in correct sequence: 1) Safety boots, 2) Coverall/apron, 3) Face shield/goggles, 4) Gloves (ensure cuffs overlap coverall sleeves by minimum 100mm). Buddy check completed - second person verifies correct PPE and fit. Remove watches, jewellery, and ensure long hair tied back. Ensure mobile phone/radio accessible outside contaminated gloves.

Critical Hold-Point: HOLD POINT - Supervisor must verify PPE compliance before work commences. Damaged or incorrect PPE must be replaced immediately. Do not use latex gloves - insufficient chemical resistance.
3

Container Opening and Transfer System Connection

Execution

Position container on drip tray within bunded area. Slowly loosen cap to release any pressure build-up (face turned away, arm extended). Connect chemical-resistant transfer pump ensuring grounding wire attached to prevent static discharge. Verify all connections tight and hoses free from damage/kinks. Position receiving vessel on stable surface within secondary containment. Activate LEV system and confirm capture velocity at source (minimum 1 m/s). Place absorbent pads around connection points. Keep neutralising agent (sodium thiosulphate solution) immediately accessible.

Critical Hold-Point: CRITICAL - Never force open containers or use improvised tools. If container pressurised or bulging, isolate immediately and contact supervisor. Ensure all connections made before pump activation to prevent uncontrolled release.
4

Controlled Transfer Operation

Execution

Activate transfer pump at lowest flow rate initially, gradually increasing to operational speed. Continuously monitor connections for leaks (visual inspection every 30 seconds). Maintain constant attendance - never leave transfer operation unattended. Monitor receiving vessel level to prevent overfilling (stop at 90% capacity maximum). Keep face and body positioned away from potential splash zones. If any vapour detected (chlorine odour threshold 0.3 ppm), stop immediately and increase ventilation. Record volume transferred on permit documentation. Maximum continuous transfer time 20 minutes - pause for equipment inspection if longer duration required.

Critical Hold-Point: STOP WORK IMMEDIATELY if: chlorine odour detected, leak observed, LEV system fails, or personnel feel unwell. Activate emergency procedures and evacuate to muster point upwind of release.
5

System Disconnection and Decontamination

Completion

Stop pump and allow system to drain completely (minimum 2 minutes). Carefully disconnect transfer hose over drip tray, allowing residual chemical to drain. Seal containers immediately after disconnection. Flush transfer equipment with water (if compatible with system design) into designated waste container. Wipe external surfaces of containers with damp cloth to remove any residue. Inspect bunded area and drip trays for spillage - clean with absorbent pads if required. Place contaminated materials in designated chemical waste container (UN-approved packaging). Ensure all containers correctly labelled and sealed before storage.

Critical Hold-Point: HOLD POINT - Do not remove PPE until decontamination complete and supervisor confirms area clean. Contaminated PPE must be decontaminated or disposed of as hazardous waste - never re-use without inspection.
6

PPE Removal, Welfare, and Documentation

Completion

Remove PPE in designated clean area using correct doffing sequence to avoid self-contamination: 1) Gloves (peel off inside-out), 2) Face shield (handle only headband), 3) Coverall/apron (roll inward), 4) Wash hands thoroughly with soap and water for minimum 60 seconds. Inspect skin for any signs of exposure (redness, irritation). Dispose of single-use PPE in chemical waste stream. Store reusable PPE in designated clean area after inspection. Complete permit-to-work close-out documentation including volumes transferred, any incidents/near-misses, and equipment condition. Conduct post-task debrief with all personnel. Report any exposure incidents to supervisor immediately for health surveillance referral.

Critical Hold-Point: MANDATORY - Any skin or eye contact, regardless of severity, must be reported immediately and medical assessment obtained. Do not delay seeking medical attention. Provide SDS to medical personnel.

Emergency Rescue, First Aid & Spill Protocol

EMERGENCY PROCEDURES: In event of major spillage (>5 litres) or chlorine gas release: Activate site emergency alarm, evacuate all non-essential personnel to muster point upwind of incident, contact emergency services (999) stating chemical involved. Trained emergency response team only to approach with appropriate RPE (full-face mask with ABEK-P3 filter, BS EN 14387). Contain spillage using absorbent materials and prevent entry to drains/watercourses. Notify Environment Agency (0800 807060) if environmental release occurs. FIRST AID: SKIN CONTACT - Immediately remove contaminated clothing. Rinse affected area with copious running water for minimum 15 minutes. Do NOT attempt to neutralise. Seek immediate medical attention. EYES - Rinse immediately with eyewash or clean water for minimum 15 minutes, holding eyelids open. Remove contact lenses if present and easy to do. Seek immediate emergency medical attention - eye injuries are medical emergencies. INHALATION - Remove casualty to fresh air immediately. Keep warm and at rest. If breathing difficult, administer oxygen if trained and available. Seek immediate medical attention. If breathing stops, commence CPR if trained. INGESTION - Do NOT induce vomiting. Rinse mouth with water. Give small amounts of water to drink if conscious. Seek immediate medical attention. MEDICAL INFORMATION: Provide Safety Data Sheet to medical personnel. Substance causes corrosive injury - early medical intervention critical. Health surveillance required for regular users (COSHH Regulation 11) - baseline and periodic respiratory function tests and skin examinations. Report all exposures via RIDDOR if results in >7 days absence or specified injury.

4. UK HSE Compliance FAQs: Sodium Hypochlorite (14-15% Available Chlorine) Industrial Bleach

What is the legal requirement for COSHH assessment review frequency for Sodium Hypochlorite, and what triggers an immediate review?

Under COSHH Regulation 6(3), assessments must be reviewed regularly and immediately if: (a) there is reason to suspect the assessment is no longer valid, (b) there has been significant change in the work, or (c) results of exposure monitoring or health surveillance indicate review necessary. HSE guidance recommends minimum annual review for corrosive substances. Immediate review triggers include: any exposure incident, near-miss, changes to process/equipment, new information on health effects, changes to WELs, or failure of control measures. Review must be conducted by competent person (minimum NEBOSH National Certificate in Chemical Safety or equivalent) and documented with signature and date. Employers must demonstrate assessment remains valid - failure to review is breach of COSHH Regulations and can result in enforcement action including Improvement/Prohibition Notices.

What are the specific LEV examination requirements under COSHH for Sodium Hypochlorite handling, and who can conduct the examination?

COSHH Regulation 9 requires LEV systems used to control exposure to hazardous substances must be thoroughly examined and tested at least every 14 months by a competent person. For Sodium Hypochlorite (corrosive substance generating potential chlorine gas), the examination must include: airflow measurement at capture points (minimum 1 m/s capture velocity), duct integrity inspection, filter condition assessment, fan performance verification, and alarm function testing. The competent person must hold appropriate qualifications (e.g., BOHS P601 LEV qualification, Faculty of Occupational Hygiene certification) and have specific knowledge of the substance hazards. Examination results must be recorded on form LEV1 or equivalent, signed by examiner, and kept for minimum 5 years. Defects identified must be rectified immediately if affecting control effectiveness. Employers cannot use LEV systems that have not been examined within required timeframe - this constitutes breach of COSHH and may result in prosecution.

What are the legal duties regarding provision of information, instruction and training under COSHH for employees handling Sodium Hypochlorite, and how should competency be demonstrated?

COSHH Regulation 12 places absolute duty on employers to provide adequate information, instruction and training to employees exposed or liable to be exposed to hazardous substances. For Sodium Hypochlorite handlers, this must include: nature of substance and health risks (corrosive, environmental hazard), findings of COSHH assessment, control measures and why they are necessary, how to use PPE correctly, emergency procedures including first aid, results of exposure monitoring (anonymised), collective results of health surveillance (anonymised). Training must be: provided before exposure commences, repeated periodically (recommended annually for corrosive substances), comprehensible and relevant to work undertaken, and documented with records retained. Competency must be demonstrated through: written/practical assessment, observation of safe working practices, and refresher training. Employers must ensure only competent persons handle Sodium Hypochlorite - competency framework should specify minimum qualifications (e.g., NVQ Level 2 Chemical Operations, IOSH Working Safely plus substance-specific training), supervised practice period, and assessment criteria. Failure to provide adequate training is criminal offence under COSHH and may result in prosecution following incident.

5. Operative Toolbox Talk & Competent Person Sign-Off Register

Competent Person & Operative Declaration: By signing below, the Site Supervisor confirms this assessment has been adapted and verified for actual site conditions, and operatives confirm they have attended the pre-start Toolbox Talk for Sodium Hypochlorite (14-15% Available Chlorine) Industrial Bleach and will follow the safe system of work.

Operative / Supervisor Name Trade / Role & CSCS No. Signature Date & Time
1. (Site Supervisor):     
2.     
3.     
4.     
5.     
6.     

Related UK Safety Templates & Risk Assessments