SafeSequence › UK Safety Template Library › COSHH & Chemical Safety › Mild & Stainless Steel MIG/TIG Welding Fume (Hexavalent Chromium & Nickel Oxide)
Verified UK COSHH Standard • COSHH & Chemical Safety

Mild & Stainless Steel MIG/TIG Welding Fume (Hexavalent Chromium & Nickel Oxide) (COSHH Template & 5x5 Risk Assessment)

This COSHH assessment addresses the significant health risks associated with MIG and TIG welding of mild and stainless steel, specifically focusing on exposure to hexavalent chromium (Cr(VI)) and nickel oxide fume. Stainless steel welding generates carcinogenic Cr(VI) at concentrations that routinely exceed the Workplace Exposure Limit (WEL) of 0.025 mg/m³ (8-hour TWA) and 0.05 mg/m³ (15-minute STEL) as specified in EH40/2005. Following HSE Safety Alert STSU1-2019, this assessment mandates on-torch Local Exhaust Ventilation (LEV) as the primary engineering control, supplemented by air-fed Respiratory Protective Equipment (RPE) for operations where LEV alone cannot achieve adequate control. The assessment incorporates a hierarchy of controls including elimination/substitution (where practicable), engineering controls (mandatory on-torch extraction with minimum capture velocity of 1 m/s at 150mm from source), administrative controls (permit-to-work, competency verification, health surveillance under COSHH Regulation 11), and appropriate PPE. All welding operatives must hold valid welding certification, complete COSHH awareness training, and undergo baseline and periodic medical surveillance including respiratory function testing. LEV systems require thorough examination and testing at 14-month intervals per COSHH Regulation 9. This assessment is valid for 12 months or upon significant process change, whichever occurs first.

Statutory FrameworkCOSHH 2002, HSE Safety Alert STSU1-2019 (Mandatory On-Torch LEV / Air-Fed RPE), EH40/2005
ClassificationWelding fume is classified as IARC Group 1 (carcinogenic to humans). Hexavalent chromium compounds: GHS Classification - Carc. 1A (H350: May cause cancer by inhalation), Muta. 1B (H340), Resp. Sens. 1 (H334), Skin Sens. 1 (H317), STOT RE 1 (H372). Nickel oxide: GHS Classification - Carc. 2 (H351), Resp. Sens. 1 (H334), STOT RE 2 (H373). UK WEL (EH40/2005): Cr(VI) compounds 0.025 mg/m³ 8-hr TWA, 0.05 mg/m³ 15-min STEL; Nickel and inorganic compounds 0.1 mg/m³ 8-hr TWA (inhalable fraction). Stainless steel welding fume: 5 mg/m³ 8-hr TWA (respirable fraction). Biological Monitoring: Chromium in urine (end of shift, end of week) - guidance value 10 μmol/mol creatinine. Mandatory health surveillance required under COSHH Regulation 11 Schedule 6.
Required Plant / KitMIG/TIG welding equipment with integrated on-torch fume extraction (minimum capture velocity 1 m/s at 150mm, compliant with BS EN ISO 21904-1:2020) • High-vacuum mobile or fixed LEV system with HEPA filtration (H13 minimum per BS EN 1822-1, tested to BS EN ISO 15012-1:2013) • Personal air sampling pumps with IOM sampler heads for inhalable dust and respirable crystalline silica monitoring (calibrated to ±5%) • Welding fume test kit with colorimetric detector tubes for hexavalent chromium (0.005-0.5 mg/m³ range, HSE MDHS 52/4 compliant) • Lockable welding gas cylinder trolley with restraint chains and flashback arrestors (BS EN ISO 5175:2017 compliant)
Review Cycle12 Months / Post-Incident
Instant AI Customization or Free Blank Word (.doc) Download

Need this COSHH customized with your Company Name, Site Postcode & Nearest A&E Hospital?

Dictate your site specifics on your phone in 45 seconds to auto-compile a signed PDF—or download our free blank Word (.doc) shell below.

Auto-Fill via Voice / CLP (45s)

2. 5×5 Hazard Risk Assessment Matrix (HASAWA 1974 / MHSWR 1999)

Identified Hazard & HarmInitial Risk (L×S)Mandatory Engineering, Isolation & Procedural ControlsResidual Risk
1. Inhalation of hexavalent chromium (Cr(VI)) fume from stainless steel welding
Harm: Lung cancer, nasal septum perforation, occupational asthma, chrome ulceration of skin. Latency period 10-30 years for malignancy. IARC Group 1 carcinogen.
5 × 5 = 25Mandatory on-torch LEV with minimum 1 m/s capture velocity at 150mm (BS EN ISO 15012-1). Air-fed RPE (APF 40, BS EN 14594) when LEV inadequate. LEV thorough examination every 14 months (COSHH Reg 9). Personal air monitoring (MDHS 52/4) quarterly. Health surveillance (COSHH Reg 11 Schedule 6) including respiratory function tests and biological monitoring (urinary chromium <10 μmol/mol creatinine). Permit-to-work for confined space welding. Substitute austenitic stainless with lower-chromium grades where specification permits.3 × 4 = 12
2. Inhalation of nickel oxide fume and respirable welding particulate
Harm: Respiratory sensitisation, occupational asthma, nasal/lung cancer (IARC Group 1), metal fume fever, chronic obstructive pulmonary disease (COPD).
5 × 4 = 20On-torch LEV with HEPA H13 filtration (BS EN 1822-1) capturing 99.95% of 0.3μm particles. Air-fed RPE for operations exceeding 0.1 mg/m³ nickel WEL. Segregate stainless welding to designated, mechanically ventilated area (minimum 10 air changes/hour). Personal air sampling (IOM sampler, MDHS 14/4) at start of contract and quarterly. Pre-employment and annual respiratory health surveillance including spirometry (FEV1, FVC). Biological monitoring for nickel in urine (end of shift). Prohibit eating/drinking/smoking in welding areas to prevent ingestion.3 × 3 = 9
3. Acute exposure to welding fume in confined spaces or inadequately ventilated areas
Harm: Acute respiratory distress, metal fume fever (flu-like symptoms within 4-12 hours), asphyxiation from displacement of oxygen by shielding gas (argon/CO₂), loss of consciousness.
4 × 5 = 20Confined Space Entry Permit mandatory (Confined Spaces Regulations 1997). Pre-entry atmospheric testing (O₂ >19.5%, <23.5%; LEL <10%; toxic gas 2 × 4 = 8
4. Skin contact with hexavalent chromium compounds and nickel sensitisation
Harm: Allergic contact dermatitis, chrome ulcers ('chrome holes'), skin sensitisation (Type IV hypersensitivity), potential systemic absorption through damaged skin.
4 × 3 = 12Impervious chrome leather welding gauntlets (BS EN 12477, minimum 400mm length). Flame-retardant coveralls with mandarin collar (BS EN ISO 11611 Class 2) laundered weekly by approved contractor to prevent take-home contamination. Barrier skin creams (pre-work) and emollient creams (post-work) applied to exposed skin. Dedicated washing facilities with warm water, mild soap, and nail brushes provided at exit from welding area. Prohibit dry sweeping; use HEPA-filtered vacuum or wet methods for fume residue removal. Skin surveillance (visual inspection) during health surveillance appointments. Immediate removal from exposure if sensitisation occurs.2 × 2 = 4
5. Failure or inadequate performance of LEV system leading to excessive fume exposure
Harm: Chronic exposure to carcinogenic fume exceeding WEL, leading to lung cancer, respiratory disease, and regulatory enforcement action (Improvement/Prohibition Notice).
4 × 4 = 16LEV thorough examination and test (TExT) every 14 months by competent person (COSHH Reg 9, HSG258). Daily pre-use checks by operator (visual inspection, airflow indicator, audible alarm test). Quarterly face velocity measurements at capture hood (target ≥1 m/s at 150mm, record on LEV logbook). Automatic interlock preventing welding equipment operation if LEV fails or airflow drops below 80% of design specification. Standby/backup LEV unit for critical operations. HEPA filter replacement per manufacturer schedule or when pressure drop exceeds design limit. Annual competent person review of LEV effectiveness with personal air monitoring validation. Immediate work cessation if LEV failure detected until repair verified.2 × 3 = 6

3. Step-by-Step Safe Sequence of Operations & Hold-Points

1

Obtain Hot Work Permit and verify LEV system operational status

Pre-Work Preparation & Permit Authorisation

Complete Hot Work Permit and COSHH Task-Specific Risk Assessment. Verify LEV system operational: check airflow indicator shows green/normal, listen for abnormal noise, inspect flexible extraction arm for damage/blockage. Record LEV pre-use check in logbook with date, time, and operative signature. Confirm LEV TExT certificate in date (within 14 months). For confined space work, obtain separate Confined Space Entry Permit with atmospheric test results (O₂, LEL, toxic gas) attached. Verify competency: check welder holds valid coded welder approval (BS EN ISO 9606-1 or equivalent) and COSHH awareness training (refreshed annually). Confirm health surveillance up to date (respiratory questionnaire, spirometry within 12 months). Notify adjacent workers and erect welding screens (BS EN ISO 25980) to protect from UV radiation.

Critical Hold-Point: STOP: Do NOT commence welding if LEV system fails pre-use check or TExT certificate expired. Do NOT enter confined space without valid permit, atmospheric testing, and air-fed RPE. Welding without adequate fume control is a breach of COSHH Regulation 7 and may result in Prohibition Notice.
2

Position on-torch extraction and verify capture velocity at source

Engineering Control Activation & Verification

Position on-torch fume extraction nozzle/shroud within 150mm of welding arc and at 45-60° angle to workpiece to maximise capture without interfering with shielding gas flow. Switch on LEV system and allow 30 seconds for airflow stabilisation. Using calibrated anemometer or smoke tube, verify capture velocity ≥1.0 m/s at 150mm from arc position. For fixed LEV hoods, ensure workpiece positioned within effective capture zone (typically 1.5 × hood diameter). Confirm HEPA filter pressure drop within normal range (check manometer/digital display). If welding stainless steel or nickel alloys, don air-fed RPE (BS EN 14594 TH3/TM3, APF 40) and perform positive/negative pressure seal check. Ensure RPE air supply hose does not create trip hazard and is protected from hot work damage. Activate welding fume alarm (if fitted) to alert if LEV fails during operation.

Critical Hold-Point: HOLD POINT: Verify capture velocity ≥1.0 m/s before striking arc. For stainless steel welding, air-fed RPE is MANDATORY per HSE STSU1-2019 if LEV alone cannot achieve <0.025 mg/m³ Cr(VI). Inadequate extraction will result in WEL exceedance within minutes.
3

Execute welding with continuous fume extraction and positional awareness

Welding Operation with Continuous Monitoring

Maintain on-torch extraction nozzle within 150mm of arc throughout welding operation; reposition as work progresses. Avoid blocking extraction inlet with torch body, hands, or workpiece. Monitor LEV airflow indicator continuously; if indicator changes to amber/red or audible alarm sounds, cease welding immediately and investigate. For multi-pass welds, allow 30 seconds between passes for fume clearance. Minimise arc-on time; use pulsed welding parameters where specification permits to reduce fume generation. Avoid welding in direct draught from doors/windows which can disrupt LEV capture efficiency. If welding in confined space, ensure forced ventilation operates continuously and standby person maintains visual/communication contact. Rotate welders every 2 hours for high-fume operations to limit individual exposure. Do not eat, drink, smoke, or apply cosmetics during welding or before washing hands and face.

Critical Hold-Point: STOP WORK IMMEDIATELY if LEV fails (airflow indicator red, alarm sounds, or visible fume escape from capture zone). Do not attempt to continue welding. Evacuate confined spaces if O₂ drops below 19.5% or fume visible. Report LEV failure to supervisor and maintenance before resuming.
4

Handle welded components and consumables to prevent secondary exposure

Material Handling & Contamination Control

Allow welded components to cool before handling; use heat-resistant gloves (BS EN 407) if handling warm items. Do not use compressed air to blow dust/fume residue from workpieces or clothing (generates respirable aerosol). Use HEPA-filtered vacuum (H13 minimum) or damp cloth to remove fume deposits from work surfaces and equipment. Store welding consumables (wire, electrodes, flux) in sealed containers in dry, ventilated storage to prevent moisture absorption and hydrogen cracking. Dispose of used welding wire offcuts, slag, and spatter in designated metal waste bins (not general waste). Remove heavily contaminated PPE (gauntlets, coveralls) before leaving welding area to prevent spread of Cr(VI) contamination. Do not take contaminated PPE home for laundering; use approved industrial laundry service.

Critical Hold-Point: NEVER use compressed air to clean welding fume residue—this creates a respirable aerosol exceeding WEL. NEVER dry sweep fume deposits. Contaminated PPE taken home can expose family members to carcinogenic Cr(VI) via take-home pathway.
5

Decontaminate work area and perform thorough personal washing

Post-Weld Decontamination & Personal Hygiene

Continue LEV operation for minimum 5 minutes after final arc extinguished to clear residual fume. Vacuum work area, welding bench, and equipment with HEPA-filtered vacuum; pay attention to horizontal surfaces where fume settles. Wipe down on-torch extraction nozzle and flexible arm with damp cloth. Inspect and empty LEV pre-filter (if fitted) when 70% loaded; dispose of filter media as hazardous waste (EWC 15 02 02*). Remove RPE (if worn) after leaving fume-contaminated area; clean face seal area and store in clean, dry cabinet. Remove welding gauntlets and coveralls; inspect for damage (holes, tears, excessive contamination) and replace if compromised. Wash hands, forearms, face, and neck thoroughly with mild soap and warm water; use nail brush to remove fume deposits from under nails. Apply emollient hand cream. Do not eat, drink, or smoke until washing complete. Report any skin irritation, respiratory symptoms, or equipment defects to supervisor immediately.

Critical Hold-Point: Failure to wash thoroughly before eating/drinking/smoking can result in ingestion of carcinogenic Cr(VI) and nickel compounds. Fume deposits on skin can cause chrome ulcers and sensitisation. Always wash before leaving welding area.
6

Complete exposure records and attend mandatory health surveillance

Documentation, Monitoring & Health Surveillance

Record welding activity in COSHH exposure logbook: date, duration, material welded (mild/stainless steel), LEV system used, any LEV failures/defects, and RPE worn. Sign and date Hot Work Permit closure section; confirm fire watch completed (60 minutes post-welding). For personal air monitoring days (quarterly minimum), wear IOM sampler for full shift; record start/end times and activities. Submit sampler to UKAS-accredited laboratory for analysis (MDHS 52/4 for Cr(VI), MDHS 14/4 for inhalable dust/nickel). Review results with occupational health provider; if exposure >50% WEL, investigate controls and increase monitoring frequency. Attend mandatory health surveillance appointments (baseline, 6 months, then annually): respiratory questionnaire, spirometry (FEV1, FVC), skin inspection, and biological monitoring (urinary chromium). Report any respiratory symptoms (cough, wheeze, breathlessness), skin changes (ulcers, rash), or nasal symptoms (bleeding, crusting) immediately. Maintain personal exposure and health surveillance records for 40 years (COSHH Regulation 12).

Critical Hold-Point: Health surveillance is a legal requirement under COSHH Regulation 11 Schedule 6 for Cr(VI) exposure. Failure to attend appointments may result in removal from welding duties. Early detection of respiratory sensitisation or chrome ulceration requires immediate cessation of exposure to prevent permanent harm.

Emergency Rescue, First Aid & Spill Protocol

4. UK HSE Compliance FAQs: Mild & Stainless Steel MIG/TIG Welding Fume (Hexavalent Chromium & Nickel Oxide)

5. Operative Toolbox Talk & Competent Person Sign-Off Register

Competent Person & Operative Declaration: By signing below, the Site Supervisor confirms this assessment has been adapted and verified for actual site conditions, and operatives confirm they have attended the pre-start Toolbox Talk for Mild & Stainless Steel MIG/TIG Welding Fume (Hexavalent Chromium & Nickel Oxide) and will follow the safe system of work.

Operative / Supervisor Name Trade / Role & CSCS No. Signature Date & Time
1. (Site Supervisor):     
2.     
3.     
4.     
5.     
6.     