This COSHH assessment addresses the significant health hazards associated with two-pack (2K) isocyanate-based polyurethane spray coating operations in industrial settings. Isocyanates (including HDI, TDI, MDI) are highly reactive chemicals classified under GHS02 (flammable), GHS07 (harmful), and GHS08 (serious health hazard - respiratory sensitisation). Exposure via inhalation or skin contact can cause occupational asthma, dermatitis, and long-term respiratory impairment. This template ensures compliance with COSHH Regulations 2002 (as amended), HSE INDG388 (Working with isocyanates), and EH40/2005 Workplace Exposure Limits. Control measures prioritise engineering controls (spray booth ventilation, LEV), strict PPE protocols (RPE with assigned protection factor ≥40), biological monitoring, health surveillance under Regulation 11, and emergency decontamination procedures. All operatives must complete isocyanate-specific training and medical fitness assessments before commencing work.
| Identified Hazard & Harm | Initial Risk (L×S) | Mandatory Engineering, Isolation & Procedural Controls | Residual Risk |
|---|---|---|---|
| 1. Inhalation of isocyanate vapour/aerosol during spray application causing respiratory sensitisation Harm: Occupational asthma (irreversible), chronic obstructive pulmonary disease (COPD), hypersensitivity pneumonitis, potential fatality from acute bronchospasm |
4 × 5 = 20 | Engineering: Fully enclosed downdraught spray booth with LEV achieving ≥0.5 m/s face velocity, verified quarterly by competent person. Administrative: Permit-to-work system, atmospheric monitoring (real-time isocyanate detection <0.02 mg/m³ TWA), mandatory PAPR with APF ≥40, health surveillance (spirometry) every 12 months under Regulation 11 COSHH, biological monitoring of urinary hexamethylene diamine (HDA) metabolites. Isolation: Restrict access to authorised, trained operatives only; interlock spray booth operation with ventilation system. | 2 × 3 = 6 |
| 2. Dermal contact with liquid isocyanate components causing skin sensitisation and chemical burns Harm: Allergic contact dermatitis (chronic), chemical burns to skin and eyes, systemic absorption leading to respiratory sensitisation |
5 × 4 = 20 | Engineering: Closed-transfer systems for mixing and filling operations, automated dispensing equipment to minimise manual handling. Administrative: Mandatory Type 4/5 coveralls with integrated hood, isocyanate-resistant gloves (BS EN 374 Type A, >480 min breakthrough), immediate decontamination protocol (remove contaminated clothing, wash with soap and water for 15 minutes), pre-work skin checks and post-exposure surveillance. Substitution: Evaluate lower-volatility isocyanate prepolymers (e.g. HDI-based vs TDI) where feasible. Isolation: Segregated changing facilities with contaminated/clean zones. | 2 × 2 = 4 |
| 3. Fire and explosion risk from flammable solvents (xylene, acetates) in spray booth environment Harm: Catastrophic fire/explosion causing multiple fatalities, severe burns, structural collapse, environmental contamination |
3 × 5 = 15 | Engineering: ATEX-rated spray booth (Zone 1/2 classification), explosion-proof electrical equipment and lighting, earthing/bonding of all conductive equipment, automatic fire suppression system (CO₂ or foam), LEV system with spark detection and suppression. Administrative: Hot work permit system, prohibition of ignition sources within 10m exclusion zone, flammable atmosphere monitoring (<10% LEL), maximum 5 litres of mixed material in booth at any time, daily inspection of electrical equipment and ventilation interlocks. Isolation: Store unmixed components in flammable storage cabinet (BS EN 14470-1) outside spray area, LOTO procedures for maintenance. | 1 × 5 = 5 |
| 4. Inadequate ventilation leading to accumulation of toxic vapours exceeding WEL (0.02 mg/m³ TWA) Harm: Acute respiratory distress, chemical pneumonitis, loss of consciousness, long-term lung damage, potential fatality |
4 × 4 = 16 | Engineering: LEV system with minimum 20 air changes per hour, continuous airflow monitoring with audible/visual alarms, automatic spray gun interlock if ventilation fails, quarterly thorough examination and test (TExT) by LEV competent person per HSG258. Administrative: Pre-start ventilation checks (5-minute purge before entry), personal air sampling every 6 months, real-time isocyanate monitors with alarm set at 50% WEL (0.01 mg/m³), emergency evacuation procedure if WEL exceeded, documented LEV maintenance records. Isolation: Booth access restricted during spray operations, warning signs and flashing beacons when booth operational. | 2 × 3 = 6 |
| 5. Exothermic reaction during mixing of isocyanate (Part A) and polyol (Part B) components causing thermal burns or pressure build-up Harm: Thermal burns to hands/face, violent ejection of hot material, container rupture, inhalation of elevated isocyanate vapour from heated mixture |
3 × 3 = 9 | Engineering: Use calibrated automated mixing equipment with temperature monitoring and pressure relief, mix in well-ventilated area or fume cupboard, use containers with vented lids rated for exothermic reactions. Administrative: Follow manufacturer's mixing ratio precisely (typically 2:1 or 4:1 by volume), add isocyanate to polyol slowly (never reverse), maximum batch size 5 litres, monitor pot life (typically 20-45 minutes at 20°C), mandatory face shield and thermal gloves during manual mixing, SOP with step-by-step mixing procedure. Isolation: Designated mixing area separate from spray booth, restrict to trained personnel, emergency eyewash and drench shower within 10 seconds travel time. | 1 × 3 = 3 |
Complete pre-shift health questionnaire (respiratory symptoms, skin condition). Don PPE in correct sequence: coveralls, boots, gloves, PAPR (conduct fit-check and flow test). Verify spray booth LEV operational: check airflow indicator shows green (≥0.5 m/s), test audible alarm, confirm 5-minute pre-purge completed. Inspect spray gun and hoses for damage/leaks. Confirm emergency eyewash and spill kit accessible. Obtain permit-to-work signed by supervisor. Check atmospheric monitoring equipment calibrated and operational (isocyanate detector reading <0.01 mg/m³).
Work in designated mixing area with LEV active. Verify components are at correct temperature (18-25°C). Using automated dispensing equipment or closed-pour system, add Part A (isocyanate) SLOWLY to Part B (polyol) in correct ratio per technical datasheet (typically 2:1 or 4:1). Never reverse addition order. Mix gently using explosion-proof agitator for 2-3 minutes until homogeneous. Add thinners/reducers if specified (max 10% by volume). Strain mixed material through 125-micron filter into spray gun cup. Record batch number, mix time, and pot life expiry on permit. Maximum batch size: 5 litres. Seal component containers immediately after use.
Position workpiece on turntable/jig within spray booth. Close booth doors and activate extraction (confirm negative pressure). Conduct test spray pattern on sample panel. Apply coating in smooth, overlapping passes maintaining 200-300mm distance from substrate. Keep spray gun perpendicular to surface. Apply multiple thin coats (typically 2-3 coats at 50-75 microns DFT per coat) with flash-off time between coats (5-10 minutes). Monitor real-time isocyanate levels on personal monitor (must remain <0.02 mg/m³ TWA). Limit continuous spraying to 30-minute periods with 10-minute breaks outside booth. Maintain booth airflow throughout application and flash-off period.
Flush spray gun and hoses with compatible solvent (acetone, MEK, or manufacturer-recommended cleaner) immediately after use. Conduct flushing inside spray booth with LEV active or in designated cleaning station with LEV. Collect waste solvent in sealed, labelled metal container (UN-approved for Class 3 flammable liquids). Dismantle spray gun and clean components with solvent-soaked cloth. Inspect seals and gaskets for degradation; replace if swollen or damaged. Allow equipment to air-dry in ventilated area. Dispose of contaminated cloths in sealed metal waste bin (self-closing lid). Never use compressed air to blow out spray equipment (generates aerosol).
Remain in designated doffing area. Remove outer gloves and dispose in hazardous waste bin. Remove coveralls by rolling inside-out from shoulders downward (avoid contact with outer surface); dispose in hazardous waste bin. Remove boots/overshoes. Remove PAPR headtop and place in designated storage/charging station. Remove inner gloves last. Wash hands and forearms thoroughly with soap and water for minimum 2 minutes. Wash face and neck. Inspect skin for signs of contamination or irritation. Change into clean clothing. Contaminated PPE must not be taken home or re-used (single-use items). Reusable PAPR components cleaned and disinfected per manufacturer's instructions.
Record atmospheric monitoring results in COSHH exposure log (personal isocyanate exposure, booth airflow readings, duration of exposure). Complete permit-to-work close-out section. Report any equipment malfunctions, PPE failures, or near-miss incidents to supervisor. Conduct post-shift health self-assessment (respiratory symptoms, skin irritation). Store unused mixed material as hazardous waste (do not return to original containers). Ensure spray booth remains ventilated for minimum 30 minutes post-application. Lock flammable storage cabinet. Confirm emergency equipment (eyewash, spill kit) restocked if used. Submit biological monitoring samples (urine sample for HDA metabolites) if scheduled (typically every 6 months).
INHALATION: Remove casualty to fresh air immediately. Remove contaminated PPE. If breathing is difficult, administer oxygen if trained and available. If breathing has stopped, commence CPR if qualified. Seek immediate medical attention - inform medics of isocyanate exposure and provide SDS. Monitor for delayed respiratory symptoms (up to 24 hours). SKIN CONTACT: Remove contaminated clothing immediately. Wash affected area with soap and water for minimum 15 minutes. Do NOT use solvents on skin. Seek medical attention if irritation, rash, or sensitisation develops. Bag contaminated clothing as hazardous waste. EYE CONTACT: Irrigate eyes with clean water or eyewash for minimum 15 minutes, holding eyelids open. Remove contact lenses if present and easy to do. Seek immediate medical attention - risk of corneal damage. INGESTION: Do not induce vomiting. Rinse mouth with water. Seek immediate medical attention. Provide SDS to medical personnel. FIRE: Evacuate area immediately. Activate fire alarm. Use CO₂, foam, or dry powder extinguishers (do NOT use water jet - spreads flammable liquid). Wear BA and chemical-protective suit. Notify Fire Service of isocyanate and flammable solvent involvement. SPILL: Evacuate area and restrict access. Eliminate ignition sources. Wear full PPE including PAPR. Contain spill with absorbent pads/booms. Neutralise with polyol or amine-based neutraliser if available. Absorb with vermiculite or sand. Collect waste in sealed, labelled container (hazardous waste EWC 08 01 11*). Ventilate area thoroughly. Do not wash into drains. Report spills >1 litre to Environment Agency (0800 807060). EMERGENCY CONTACTS: Emergency Services 999, HSE Incident Contact Centre 0345 300 9923, National Poisons Information Service 0344 892 0111."
Competent Person & Operative Declaration: By signing below, the Site Supervisor confirms this assessment has been adapted and verified for actual site conditions, and operatives confirm they have attended the pre-start Toolbox Talk for Two-Pack (2K) Isocyanate Polyurethane Industrial Spray Coating and will follow the safe system of work.
| Operative / Supervisor Name | Trade / Role & CSCS No. | Signature | Date & Time |
|---|---|---|---|
| 1. (Site Supervisor): | |||
| 2. | |||
| 3. | |||
| 4. | |||
| 5. | |||
| 6. |