Under COSHH 2002 (as amended), REACH, CLP Regulation, Food Safety Act 1990, and HSG258, employers must assess and control exposure to Rocol Foodlube Hi-Torque Plus NSF H1 Grease through elimination, substitution, engineering controls, and PPE. This NSF H1-registered calcium sulfonate complex grease requires isolation of machinery during application, prevention of skin contact, and adherence to EH40 workplace exposure limits to reduce dermal sensitisation and mechanical injury risks to tolerable levels (residual risk ≤6). Rocol Foodlube Hi-Torque Plus is a premium NSF H1-registered food-grade grease designed for high-load applications in food processing and pharmaceutical manufacturing environments. This calcium sulfonate complex grease provides exceptional extreme pressure performance, water resistance, and oxidation stability across temperatures from -20°C to +150°C. The product is formulated for incidental food contact applications where lubrication of equipment may result in occasional contact with food products, complying with FDA 21 CFR 178.3570 and ISO 21469 standards. Common applications include bearings, gears, chains, and sliding surfaces in bakeries, dairies, breweries, meat processing plants, and bottling facilities where conventional lubricants pose contamination risks.
| Identified Hazard & Harm | Initial Risk (L×S) | Mandatory Engineering, Isolation & Procedural Controls | Residual Risk |
|---|---|---|---|
| 1. Skin contact causing dermatitis, defatting, and sensitisation Harm: Prolonged or repeated skin contact with mineral oil-based grease may cause removal of natural skin oils (defatting), leading to dryness, cracking, irritation, and occupational contact dermatitis. Chronic exposure increases risk of folliculitis and oil acne. | 4 × 3 = 12 | Implement strict no-touch policy using grease guns and applicators. Provide nitrile gloves conforming to BS EN 374-1:2016 with documented breakthrough time data. Install hand-washing stations with pH-neutral skin cleansers (avoid solvents). Implement pre-work skin protection creams and post-work replenishing creams. Conduct annual skin surveillance under occupational health programme. Provide barrier creams certified to BS EN 1500 where glove use is impractical. Train operatives in correct glove donning/doffing to prevent contamination. | 3 × 2 = 6 |
| 2. Injection injury from high-pressure grease gun Harm: Grease guns operating at 207-414 bar (3,000-6,000 psi) can inject grease through skin into subcutaneous tissue, causing severe tissue damage, compartment syndrome, amputation risk, and potential systemic toxicity requiring emergency surgical debridement. | 2 × 5 = 10 | Use grease guns fitted with pressure relief valves set to maximum 400 bar. Never point nozzle at body parts or test pressure with fingers. Implement permit-to-work system for high-pressure lubrication tasks. Ensure grease gun trigger guards are functional. Inspect hoses and couplings daily for wear, cracks, or leaks before use. Lock out and depressurise equipment before disconnecting fittings. Train operatives in high-pressure injection injury recognition and emergency response (immediate A&E referral within 1 hour). Display emergency procedure posters at lubrication points. | 1 × 5 = 5 |
| 3. Slips, trips, and falls on grease-contaminated surfaces Harm: Spilled or over-applied grease creates extremely slippery walking surfaces, increasing risk of same-level falls resulting in fractures, head injuries, lacerations, and soft tissue damage. Risk elevated on smooth concrete, tiled, or coated floors. | 4 × 3 = 12 | Use drip trays and absorbent mats beneath all lubrication points. Clean spills immediately using food-grade degreasing agents and absorbent granules (not sawdust in food areas). Apply anti-slip floor coatings in lubrication zones. Implement 'clean-as-you-go' policy with documented checks. Provide mobile spill kits at each lubrication station containing absorbent pads, granules, and disposal bags. Cordon off contaminated areas until cleaned. Conduct quarterly slip-resistance testing using pendulum test method (BS 7976-2:2002). Ensure adequate lighting (minimum 200 lux) at lubrication points. | 2 × 3 = 6 |
| 4. Entanglement or crush injury during machinery lubrication Harm: Contact with rotating shafts, gears, chains, or moving parts during lubrication activities can cause entanglement of clothing, gloves, or hair, resulting in traumatic amputation, degloving injuries, fractures, or fatality. | 3 × 5 = 15 | Implement mandatory Lockout/Tagout (LOTO) procedures conforming to BS EN ISO 14118:2018 before accessing lubrication points on machinery. Isolate electrical supplies, dissipate stored energy (hydraulic, pneumatic, gravitational), and apply personal locks. Verify zero-energy state using test procedures. Where LOTO is impractical, install fixed guarding with interlocked access panels (BS EN ISO 14120:2015). Prohibit loose clothing, jewellery, and require hair nets/caps. Provide task-specific training and competency assessment. Maintain LOTO register and audit compliance monthly. Install emergency stop devices within 600mm of lubrication points where machinery must run. | 1 × 5 = 5 |
| 5. Manual handling injury during grease container movement Harm: Rocol Foodlube Hi-Torque Plus is supplied in 400g cartridges, 5kg pails, 18kg pails, and 180kg drums. Manual handling of bulk containers can cause musculoskeletal disorders including lower back strain, shoulder injuries, and hernias. | 4 × 2 = 8 | Conduct task-specific manual handling risk assessments under Manual Handling Operations Regulations 1992 (as amended). Provide mechanical aids: drum trolleys, pallet trucks, and hoists for containers >12kg. Store containers at waist height (750-1050mm) to eliminate bending. Implement team lifting for 18kg pails (minimum 2 persons). Use pump systems for bulk drum dispensing to eliminate manual transfer. Train operatives in safe lifting techniques (HSE INDG143). Ensure clear access routes free from obstructions. Provide anti-fatigue matting in dispensing areas. Rotate tasks to prevent repetitive strain. | 2 × 2 = 4 |
Review lubrication schedule and identify equipment requiring Rocol Foodlube Hi-Torque Plus application. Obtain current Safety Data Sheet (SDS version 5.0 or later) and review Section 7 (Handling and Storage) and Section 8 (Exposure Controls/PPE). Complete pre-task risk assessment and obtain permit-to-work if required. Verify machinery is isolated using LOTO procedures: switch off, isolate electrical supply, apply personal padlock, dissipate stored energy, and test for zero-energy state. Cordon off work area with barriers and warning signs. Inspect grease gun, hoses, and couplings for damage or wear. Check grease cartridge/container batch number and expiry date. Assemble spill kit, drip trays, and cleaning materials. Don mandatory PPE: nitrile gloves (BS EN 374-1:2016), safety footwear (BS EN ISO 20345:2011 S2/S3 SRC), safety spectacles (BS EN 166:2001), and coveralls (BS EN 13034:2005+A1:2009). Ensure adequate ventilation and lighting (minimum 200 lux).
For cartridge loading: Unscrew grease gun barrel and fully retract plunger rod. Remove end cap from Rocol Foodlube Hi-Torque Plus 400g cartridge (do not puncture). Insert cartridge into barrel with open end facing nozzle. Remove cartridge pull-tab or seal. Screw barrel onto gun head hand-tight (do not over-tighten). Bleed air by loosening bleeder valve and pumping handle until grease appears without air bubbles, then retighten. For bulk filling: Place gun nozzle into bulk container, retract plunger fully, and pump grease into barrel. Wipe exterior of gun with lint-free cloth to remove excess grease. Check pressure relief valve is functional (should release at 400 bar maximum). Position drip tray beneath gun when not in use. Dispose of empty cartridges in designated waste stream (recyclable metal/plastic where facilities exist).
Identify lubrication points using equipment technical manual or lubrication chart. Inspect grease nipples (Zerk fittings) for damage, blockage, or cross-threading. Clean nipple and surrounding area with lint-free cloth to remove dirt, old grease, and contaminants (critical in food environments to prevent foreign body contamination). For blocked nipples, carefully remove using correct-size spanner (typically 7mm or 1/4" hex) and replace with new nipple torqued to manufacturer's specification (typically 5-8 Nm). Check bearing housing for cracks, corrosion, or damage. Verify relief/purge plugs are present and functional (allows old grease to escape, preventing over-pressurisation). Position drip tray beneath bearing to catch purged grease. Ensure grease gun coupler matches nipple type (button-head, flush, or pin). Wipe coupler with clean cloth before attachment.
Firmly attach grease gun coupler to nipple ensuring positive engagement (should require slight push and twist). Brace gun against solid surface or use two-handed grip to prevent kickback. Apply grease using slow, controlled pumps (approximately 1 pump per 2 seconds). Observe bearing housing for grease purging from relief port or seal—stop immediately when fresh grease appears (typically 2-5 pumps for small bearings, 10-20 for large bearings). For sealed bearings without relief, pump until slight resistance increase is felt (do not exceed manufacturer's pressure specification, typically 50-100 bar). Disconnect coupler by pulling straight back (not at angle). Wipe excess grease from nipple and housing. Check bearing temperature after 15-30 minutes of operation (should not exceed normal operating temperature +10°C). Record lubrication in maintenance log: date, operative name, equipment ID, grease type, and quantity applied.
Inspect all lubricated points for correct grease distribution: fresh grease should be visible at relief ports, seals should not be bulging or leaking, and no grease should be present on rotating components. Remove excess grease from external surfaces using lint-free cloths (critical in food areas to prevent contamination and pest attraction). Check floor and surrounding area for spills—clean immediately using food-grade degreaser and absorbent materials. Collect used cloths and contaminated absorbents in designated waste container (non-hazardous industrial waste unless contaminated with other substances). Verify drip trays are emptied and cleaned. Inspect PPE for contamination—remove and dispose of single-use items, clean reusable items per manufacturer's instructions. Wash hands thoroughly with pH-neutral soap and warm water (do not use solvents or abrasive cleaners). Apply post-work skin replenishing cream. Store grease gun in clean, dry location with nozzle protected from contamination.
Replace all guards, covers, and access panels removed during lubrication. Verify all fasteners are tightened to specification. Remove LOTO devices in reverse order of application (last person to lock out is first to remove lock). Restore energy sources: electrical, pneumatic, hydraulic. Conduct pre-start checks per equipment operating procedures. Start equipment and observe for 5 minutes: listen for unusual noise (grinding, squealing indicating insufficient lubrication or bearing damage), check for vibration (may indicate over-greasing or misalignment), monitor bearing temperature using infrared thermometer (should stabilise within 10°C of normal operating temperature). Verify no grease leakage from seals. Complete maintenance documentation: lubrication record, LOTO log, permit-to-work closure. Update equipment history file. Report any abnormalities to engineering/maintenance supervisor. File SDS and risk assessment in site COSHH register. Schedule next lubrication interval per manufacturer's recommendations (typically 500-2000 operating hours or 3-6 months for Rocol Foodlube Hi-Torque Plus in food industry applications).
Competent Person & Operative Declaration: By signing below, the Site Supervisor confirms this assessment has been adapted and verified for actual site conditions, and operatives confirm they have attended the pre-start Toolbox Talk for Rocol Foodlube Hi-Torque Plus NSF H1 Grease and will follow the safe system of work.
| Operative / Supervisor Name | Trade / Role & CSCS No. | Signature | Date & Time |
|---|---|---|---|
| 1. (Site Supervisor): | |||
| 2. | |||
| 3. | |||
| 4. | |||
| 5. | |||
| 6. |