SafeSequence › UK Safety Template Library › Commercial Brand COSHH › Henkel Loctite 243 / 270 Anaerobic Threadlocker & 401 Cyanoacrylate
Reference UK COSHH Example • Commercial Brand COSHH

Henkel Loctite 243 / 270 Anaerobic Threadlocker & 401 Cyanoacrylate (COSHH Template & 5x5 Risk Assessment)

Under COSHH Regulations 2002 (as amended), employers must prevent or adequately control exposure to Henkel Loctite 243/270 anaerobic threadlockers and 401 cyanoacrylate adhesive, classified under CLP Regulation with GHS07 pictogram for Skin Sensitiser (H317) and Eye Irritant (H319). Mandatory engineering controls include local exhaust ventilation (LEV) achieving ≥0.5 m/s capture velocity, isolation of application areas, and adherence to EH40/2005 workplace exposure limits. Target residual risk: ≤6 (Low) through hierarchy of controls, respiratory protection factor (APF) ≥10, and dermal exposure prevention to reduce initial risk scores from 12-15 (Medium-High) to acceptable levels.

Statutory FrameworkCOSHH Regulations 2002, CLP Regulation (GHS07 Skin Sensitiser H317 & Eye Irritant H319), EH40/2005
Classification**CLP/GHS Classification:** Loctite 243/270 (Anaerobic Threadlocker): GHS07 - Skin Sens. 1 (H317: May cause allergic skin reaction), Eye Irrit. 2 (H319: Causes serious eye irritation). Loctite 401 (Cyanoacrylate): GHS07 - Skin Irrit. 2 (H315), Eye Irrit. 2 (H319), STOT SE 3 (H335: May cause respiratory irritation). **UN Numbers:** Not classified as dangerous goods for transport. **EH40/2005 WELs:** Methacrylic acid esters (anaerobic component): 8-hour TWA 50 ppm (210 mg/m³), 15-min STEL 100 ppm (420 mg/m³). Cyanoacrylate vapour: No specific WEL; apply general ventilation principles and control to below irritant threshold (~0.2 ppm). **SDS Reference:** Henkel SDS versions compliant with UK REACH (retained EU law) and CLP GB-CLP labelling requirements.
Required Plant / KitLocal Exhaust Ventilation (LEV) system with flexible extraction arm (minimum 0.5 m/s capture velocity at source, tested to HSG258 standards) • Calibrated air velocity meter (anemometer) for LEV performance verification and EH40/2005 compliance monitoring • Sealed chemical storage cabinet (BS EN 14470-1 compliant) with spill containment bund for adhesive/threadlocker bottles • Precision dispensing applicators (needle-tip bottles or automated dosing equipment) to minimise skin contact and vapour release • Emergency eyewash station (BS EN 15154-2:2006 compliant) located within 10 seconds travel time of application area
Site Sign-Off StatusRequires Competent Person Verification
Instant AI Customization or Free Blank Word (.doc) Download

Need this COSHH customized with your Company Name, Site Postcode & Nearest A&E Hospital?

Dictate your site specifics on your phone in 45 seconds to auto-compile a signed PDF—or download our free blank Word (.doc) shell below.

Auto-Fill via Voice / CLP (45s)

1. Mandatory Personal Protective Equipment (BS EN Standards)

BS EN ISO 374-1:2016/A1:2018 Type B (KPT), BS EN 374-4:2013 (degradation resistance)
Nitrile chemical-resistant gloves (minimum 0.38mm thickness, breakthrough time >480 minutes for cyanoacrylate/methacrylates)
Mandatory dermal protection against H317 skin sensitisation (Loctite 243/270) and H315 skin irritation (Loctite 401). Prevents allergic contact dermatitis and acute bonding injuries from cyanoacrylate.
BS EN 166:2001 (Optical Class 1, mechanical impact rating F, chemical droplet/splash marking 3)
Safety spectacles with side shields or full-seal chemical goggles
Protects against H319 eye irritation from aerosol mist, splashes during dispensing, and accidental contact. Critical for cyanoacrylate which bonds instantly to eye tissue.
BS EN ISO 13982-1:2004 (Type 5 particulate), BS EN 13034:2005+A1:2009 (Type 6 liquid chemical splash)
Disposable Type 5/6 chemical-resistant coveralls or impermeable apron
Prevents skin sensitisation from aerosol deposition and accidental spillage onto clothing. Reduces dermal exposure route for H317 allergens during bulk dispensing or maintenance tasks.
BS EN 140:1999 (facepiece), BS EN 14387:2004+A1:2008 (Class A1 gas filter), BS EN 143:2000 (P2 particulate filter, APF=10)
Half-mask respirator with combined A1P2 filter (organic vapour + particulate)
Required when LEV inadequate or during confined space work. Controls inhalation exposure to methacrylic ester vapours (EH40/2005 WEL 50ppm TWA) and cyanoacrylate vapour (H335 respiratory irritant). Face-fit tested per HSE INDG479.

2. 5×5 Hazard Risk Assessment Matrix (HASAWA 1974 / MHSWR 1999)

Identified Hazard & HarmInitial Risk (L×S)Mandatory Engineering, Isolation & Procedural ControlsResidual Risk
1. Skin sensitisation (allergic contact dermatitis) from repeated/prolonged dermal exposure to anaerobic threadlocker methacrylate monomers (Loctite 243/270 H317)
Harm: Allergic skin reaction, eczema, chronic dermatitis requiring medical treatment and potential long-term occupational health surveillance. Sensitisation is irreversible once established.
4 × 3 = 12Engineering: Automated/semi-automated dispensing systems to eliminate hand contact. Administrative: Skin surveillance programme per HSE INDG436, pre-employment health screening for atopy. PPE: Nitrile gloves BS EN ISO 374-1:2016 Type B (mandatory, changed every 2 hours or immediately if contaminated). Barrier creams (post-work only, not pre-work). Immediate soap-and-water washing facilities. Prohibition of contaminated clothing re-use.3 × 2 = 6
2. Acute eye irritation/damage from splash or aerosol contact with cyanoacrylate (Loctite 401 H319) or anaerobic adhesive mist
Harm: Serious eye irritation, corneal abrasion, conjunctivitis. Cyanoacrylate bonds eyelids/cornea instantly, requiring emergency medical intervention and potential permanent vision impairment.
3 × 4 = 12Engineering: Enclosed dispensing booth with polycarbonate screen barrier. LEV extraction at point of application. Administrative: Permit-to-work for bulk transfers, two-person rule for large-scale application. Emergency: BS EN 15154-2 eyewash station within 10 seconds, trained first aiders. PPE: BS EN 166 chemical goggles (mandatory during all dispensing/application). Prohibition of contact lens wear in application areas.2 × 2 = 4
3. Inhalation exposure to methacrylic ester vapours exceeding EH40/2005 WEL (50ppm 8-hr TWA, 100ppm 15-min STEL) during bulk dispensing or confined space application
Harm: Respiratory irritation, headache, dizziness, nausea. Chronic exposure may cause occupational asthma (respiratory sensitisation). Exceeding STEL causes acute mucous membrane irritation.
3 × 4 = 12Engineering: LEV system HSG258-compliant (≥0.5 m/s capture velocity, quarterly thorough examination and test per COSHH Reg 9). General dilution ventilation ≥6 air changes/hour. Administrative: Atmospheric monitoring (personal/static sampling) every 12 months or after process change. Confined space entry permit with forced ventilation. Work rotation to limit exposure duration. PPE: A1P2 half-mask respirator (APF=10) when LEV unavailable or during maintenance, face-fit tested annually per HSE INDG479.2 × 3 = 6
4. Accidental bonding of skin/fingers (cyanoacrylate Loctite 401 bonds skin in <5 seconds) causing tissue trauma during separation attempts
Harm: Bonded fingers requiring mechanical separation, skin tearing, secondary infection risk, lost-time injury. Potential entrapment if bonded to machinery or tools.
4 × 3 = 12Engineering: Precision needle-tip applicators to control adhesive flow. Drip trays and absorbent matting at workstations. Administrative: Competency-based training on cyanoacrylate hazards and emergency debonding (acetone soak, warm soapy water, never force separation). Prohibition of eating/drinking/smoking in application areas. Emergency: Acetone debonding kit (non-acetone nail polish remover alternative) and first aid procedure. PPE: Nitrile gloves mandatory (double-gloving for high-risk tasks). Immediate access to warm water for passive debonding.2 × 2 = 4
5. Fire/exothermic reaction risk from bulk cyanoacrylate contact with cotton, wool, or cellulosic materials (spontaneous ignition hazard)
Harm: Localised fire, burns, smoke inhalation. Cyanoacrylate polymerisation on absorbent materials generates significant heat (up to 150°C), igniting fabric and causing rapid fire spread.
2 × 5 = 10Engineering: Segregated storage in metal cabinets away from combustibles. Stainless steel or glass work surfaces (no wood/cardboard). Spill kits with inert absorbent (vermiculite, not cloth). Administrative: Hot work permit system prohibiting welding/grinding near adhesive storage. SDS-trained personnel only. Waste disposal in sealed metal containers, removed daily. Emergency: CO₂ or dry powder fire extinguishers (water/foam ineffective). Evacuation procedure for chemical fire. PPE: Fire-resistant lab coat (not cotton) during bulk handling.1 × 4 = 4

3. Step-by-Step Safe Sequence of Operations & Hold-Points

1

Verify COSHH assessment, LEV operation, and PPE availability

Pre-Application Preparation & Risk Assessment

Confirm current COSHH assessment (reviewed ≤12 months) is displayed at workstation. Verify LEV system operational (indicator light green, audible airflow). Check anemometer reading at extraction point: ≥0.5 m/s capture velocity mandatory. Inspect nitrile gloves for tears/degradation (discard if >2 hours old or contaminated). Don BS EN 166 safety spectacles and chemical-resistant gloves. Ensure emergency eyewash station accessible and tested (weekly flush log signed). Confirm Loctite product SDS available and personnel trained (competency record signed within 12 months).

Critical Hold-Point: **HOLD POINT:** Do NOT proceed if LEV capture velocity <0.5 m/s or eyewash station non-functional. Report to supervisor immediately. Respiratory protection (A1P2 half-mask) MANDATORY if LEV defective—face-fit test certificate must be in date (≤12 months).
2

Retrieve adhesive/threadlocker from storage and establish controlled application zone

Product Retrieval & Containment Setup

Unlock chemical storage cabinet (BS EN 14470-1). Remove only the quantity of Loctite 243/270/401 required for immediate task (minimise open container time). Check bottle label for CLP GHS07 pictogram and H317/H319 hazard statements. Place bottle in secondary containment tray (spill capacity ≥110% of bottle volume). Position work within LEV capture zone (≤30cm from extraction hood). Lay down absorbent mat (inert material, NOT cotton/paper for cyanoacrylate). Ensure no food, drink, or personal items within 2-metre exclusion zone.

Critical Hold-Point: **CRITICAL:** Never store or use Loctite 401 (cyanoacrylate) near cotton rags, tissue, or cellulosic materials—exothermic reaction can cause spontaneous ignition. Keep acetone debonding kit within arm's reach for emergency skin bonding incidents.
3

Dispense adhesive/threadlocker using precision applicator with minimised skin/eye contact risk

Application & Exposure Control

Open Loctite bottle slowly to avoid pressure release (anaerobic products may pressurise). Use needle-tip applicator or automated dosing gun to apply product directly to thread/substrate—avoid hand contact. For Loctite 401 (cyanoacrylate), apply sparingly (1-2 drops per joint) to prevent excess squeeze-out. Keep face ≥30cm from application point to avoid vapour inhalation. Work in short intervals (≤15 minutes continuous application) to stay below EH40/2005 STEL (100ppm for methacrylates). Wipe applicator tip with inert cloth (not cotton) between uses. Re-seal bottle immediately after each use.

Critical Hold-Point: **STOP:** If adhesive contacts skin, DO NOT attempt to pull apart bonded surfaces—this causes skin tearing. Immediately soak in warm soapy water or apply acetone-soaked gauze for 5-10 minutes. If eyes splashed, irrigate at eyewash station for 15 minutes minimum and summon first aider—do NOT rub eyes.
4

Conduct personal/static air sampling to verify compliance with EH40/2005 WELs (if required by COSHH assessment)

Atmospheric Monitoring & Exposure Verification (Periodic)

For tasks involving bulk dispensing (>100ml/day) or confined spaces, attach personal air sampling pump to operative's breathing zone (lapel mount). Calibrate pump to 0.5-2.0 L/min per HSE MDHS96 (methacrylic esters). Run sampler for full task duration or minimum 2 hours for TWA determination. Position static sampler at workstation perimeter (1.5m height). Record start/stop times, LEV status, and task description on chain-of-custody form. Submit samples to UKAS-accredited laboratory for GC-MS analysis. Compare results to EH40/2005 WEL: 8-hr TWA 50ppm, 15-min STEL 100ppm.

Critical Hold-Point: **COMPLIANCE HOLD:** If previous monitoring indicated exposure >50% WEL (25ppm TWA), repeat sampling every 6 months. If exposure >WEL, immediately implement additional controls (upgrade LEV, reduce task duration, mandatory RPE) and notify HSE if exposure cannot be adequately controlled per COSHH Reg 11.
5

Safely dispose of contaminated materials and decontaminate work area

Waste Disposal & Decontamination

Place used applicator tips, contaminated gloves, and absorbent materials in sealed metal waste container (NOT plastic for cyanoacrylate waste—fire risk). Label container 'Hazardous Waste—Cyanoacrylate/Anaerobic Adhesive Residue' with date. Store in designated chemical waste area away from combustibles. Wipe work surface with isopropanol (IPA) or acetone-dampened cloth (wear fresh gloves). Dispose of wipe in metal waste container. Wash hands thoroughly with soap and water (do NOT use solvents on skin). Remove and inspect gloves for contamination—discard if any adhesive contact. Return Loctite bottles to locked storage cabinet. Record usage quantity in COSHH inventory log.

Critical Hold-Point: **FIRE HAZARD:** Cyanoacrylate-contaminated cotton/paper waste can spontaneously ignite within 30 minutes. Use only metal containers with tight-fitting lids. Arrange daily waste collection—do NOT allow accumulation overnight. In case of smoking/heat from waste container, evacuate area and call emergency services (do NOT attempt water extinguishment).
6

Complete exposure records and report any adverse health effects

Post-Task Review & Health Surveillance

Log task completion in COSHH exposure register: date, product used (Loctite 243/270/401), duration, LEV status, PPE worn. Note any deviations from procedure or near-miss incidents (e.g., skin contact, eye splash, LEV failure). Inspect skin for redness, itching, or rash—report immediately to occupational health if suspected allergic reaction (H317 sensitisation). Operatives with ≥10 hours/week exposure to Loctite 243/270 require annual health surveillance (skin inspection by occupational health professional per COSHH Reg 11). File exposure record in personal health file (retain 40 years per COSHH Reg 10). Supervisor to review incident trends monthly and update COSHH assessment if controls inadequate.

Critical Hold-Point: **HEALTH ALERT:** Skin sensitisation (H317) is irreversible—once sensitised, even trace exposure causes severe allergic reaction. Report ANY skin symptoms (itching, rash, blistering) within 24 hours. Sensitised workers may require permanent redeployment away from methacrylate/cyanoacrylate exposure. Delayed reporting can result in chronic occupational dermatitis and ill-health retirement.

Emergency Rescue, First Aid & Spill Protocol

**EMERGENCY CONTACTS:** First Aider: [Insert name/extension]. Occupational Health: [Insert contact]. Emergency Services: 999. Poison Centre: 0344 892 0111 (NHS 111). **SKIN CONTACT (Loctite 243/270/401):** Do NOT forcibly separate bonded skin—causes tearing. Immediately immerse in warm soapy water for 10-15 minutes; gently peel apart using rolling motion. For cyanoacrylate bonding, apply acetone-soaked gauze (or non-acetone nail polish remover) to dissolve bond. Wash thoroughly with soap and water. Remove contaminated clothing. Seek medical attention if irritation, rash, or allergic reaction develops (H317 sensitisation). **EYE CONTACT:** Immediately irrigate at BS EN 15154-2 eyewash station for minimum 15 minutes, holding eyelids open. Remove contact lenses if present and easy to do. For cyanoacrylate bonding of eyelids, do NOT force open—seek immediate emergency medical attention (A&E/999). Continue irrigation en route to hospital. **INHALATION:** Move casualty to fresh air immediately. If symptomatic (coughing, dizziness, headache), administer oxygen if trained and available. Monitor for respiratory distress. Seek medical attention if symptoms persist >30 minutes or if exposure exceeded EH40/2005 STEL (100ppm). **INGESTION (unlikely):** Do NOT induce vomiting (cyanoacrylate may bond oral/oesophageal tissue). Rinse mouth with water. Give small sips of water if conscious. Seek immediate medical attention—bring SDS. **FIRE:** Evacuate area. Use CO₂, dry powder, or foam extinguisher (water may spread burning cyanoacrylate). Cyanoacrylate fires produce toxic hydrogen cyanide and nitrogen oxides—wear SCBA if firefighting. **SPILLAGE:** Evacuate non-essential personnel. Ventilate area (open doors/windows, activate LEV). Wear full PPE (gloves, goggles, respirator if >100ml spill). Absorb with inert material (vermiculite, sand—NOT sawdust/cotton for cyanoacrylate). Scoop into metal container, seal, label as hazardous waste. Decontaminate area with IPA/acetone. Report spills >1 litre to HSE per COSHH Reg 11. **HEALTH SURVEILLANCE:** Operatives with regular exposure (≥10 hrs/week) require annual skin surveillance by occupational health professional. Maintain confidential health records for 40 years. Notify HSE of any confirmed occupational dermatitis/asthma cases via RIDDOR 2013.

4. UK HSE Compliance FAQs: Henkel Loctite 243 / 270 Anaerobic Threadlocker & 401 Cyanoacrylate

5. Operative Toolbox Talk & Competent Person Sign-Off Register

Competent Person & Operative Declaration: By signing below, the Site Supervisor confirms this assessment has been adapted and verified for actual site conditions, and operatives confirm they have attended the pre-start Toolbox Talk for Henkel Loctite 243 / 270 Anaerobic Threadlocker & 401 Cyanoacrylate and will follow the safe system of work.

Operative / Supervisor Name Trade / Role & CSCS No. Signature Date & Time
1. (Site Supervisor):     
2.     
3.     
4.     
5.     
6.     