SafeSequence › UK Safety Template Library › Commercial Brand COSHH › Geocel The Works Trade Mate Silicone Sealant
Reference UK COSHH Example • Commercial Brand COSHH

Geocel The Works Trade Mate Silicone Sealant (COSHH Template & 5x5 Risk Assessment)

Under COSHH 2002 (as amended), EH40 WELs, REACH, CLP Regulation, and HSG258 Controlling Airborne Contaminants at Work, employers must assess and control exposure to Geocel The Works Trade Mate Silicone Sealant through elimination, substitution, engineering controls, and respiratory protective equipment where workplace exposure limits may be exceeded. Adequate ventilation and isolation protocols must reduce residual risk to tolerable levels below 8 (5×5 matrix).

Statutory FrameworkCOSHH 2002 (as amended), EH40 WELs, REACH, CLP Regulation, HSG258 Controlling Airborne Contaminants at Work
ClassificationGeocel The Works Trade Mate Silicone Sealant is an acetoxy-cure silicone sealant. During curing, it releases acetic acid vapour (CAS 64-19-7). GHS/CLP Classification: Skin Corrosion/Irritation Category 2 (H315: Causes skin irritation), Eye Irritation Category 2 (H319: Causes serious eye irritation), STOT SE Category 3 (H335: May cause respiratory irritation). No UN transport classification for small consumer packages. EH40/2005 WEL for acetic acid: 10 ppm (25 mg/m³) 8-hour TWA, 15 ppm (37 mg/m³) 15-minute STEL. REACH registered substance. Store in original container below 25°C in well-ventilated area away from foodstuffs.
Required Plant / KitMechanical ventilation system or local exhaust ventilation (LEV) conforming to HSG258 with minimum 10 air changes per hour • Sealant application gun (manual or pneumatic) with controlled dispensing trigger • Surface preparation tools: scrapers, wire brushes, lint-free cloths, and approved solvent cleaners • Acetic acid vapour detection tubes or direct-reading electronic monitor (0-20 ppm range) • Spill containment kit including absorbent granules, disposal bags, and neutralising agent (sodium bicarbonate solution)
Site Sign-Off StatusRequires Competent Person Verification
Instant AI Customization or Free Blank Word (.doc) Download

Need this COSHH customized with your Company Name, Site Postcode & Nearest A&E Hospital?

Dictate your site specifics on your phone in 45 seconds to auto-compile a signed PDF—or download our free blank Word (.doc) shell below.

Auto-Fill via Voice / CLP (45s)

1. Mandatory Personal Protective Equipment (BS EN Standards)

BS EN ISO 374-1:2016/A1:2018 Type B (KPT)
Nitrile or butyl rubber chemical-resistant gloves (minimum 0.4mm thickness)
Protection against skin contact with uncured silicone sealant and acetic acid vapour condensate which causes skin irritation (H315). Nitrile provides breakthrough time >30 minutes for acetic acid.
BS EN 166:2001 (Optical Class 1, Marking: 2C-1.2 1 F)
Safety spectacles with side shields or full-face visor
Mandatory eye protection against splashes and misting during application which may cause serious eye irritation (H319). Side shields prevent lateral exposure during overhead or confined space work.
BS EN 149:2001+A1:2009
FFP2 or FFP3 filtering facepiece respirator (valved for extended use)
Respiratory protection required when applying in confined spaces, poorly ventilated areas, or when atmospheric monitoring indicates acetic acid vapour >5 ppm (50% WEL). FFP3 mandatory if STEL approached or exceeded.
BS EN ISO 20345:2011 S3 SRC
Safety footwear with slip-resistant sole and chemical-resistant upper
Protection against slips on contaminated surfaces and dropped sealant cartridges. Chemical-resistant upper prevents penetration of sealant and cleaning solvents during floor-level applications.

2. 5×5 Hazard Risk Assessment Matrix (HASAWA 1974 / MHSWR 1999)

Identified Hazard & HarmInitial Risk (L×S)Mandatory Engineering, Isolation & Procedural ControlsResidual Risk
1. Inhalation of acetic acid vapour during curing process in confined or poorly ventilated spaces
Harm: Respiratory irritation, coughing, shortness of breath, bronchospasm. Prolonged exposure above 15 ppm STEL may cause chemical pneumonitis. Asthmatics at increased risk of acute exacerbation.
4 × 3 = 12Install and verify LEV system per HSG258 achieving minimum 10 ACH. Conduct atmospheric monitoring using direct-reading acetic acid detector before, during (every 30 mins), and after application. Implement permit-to-work for confined spaces per BS EN 60079-10-1. Enforce mandatory FFP3 respirator use if vapour >5 ppm. Provide 15-minute fresh-air breaks every hour. Restrict access within 5-metre radius during application and 30 minutes post-application.2 × 2 = 4
2. Skin contact with uncured sealant causing dermatitis and sensitisation
Harm: Acute irritant contact dermatitis (H315), erythema, blistering. Repeated exposure may lead to allergic contact dermatitis and occupational skin disease requiring HSE RIDDOR reporting.
4 × 2 = 8Enforce double-gloving protocol: inner nitrile glove (0.4mm) + outer disposable glove changed every 30 minutes. Apply barrier cream (silicone-free) to forearms before work. Provide immediate access to eyewash/skin wash station within 10 metres per BS EN 15154. Implement skin surveillance programme with pre-placement and 6-monthly dermatological checks. Prohibit eating, drinking, smoking in work area. Mandatory hand washing before breaks.2 × 2 = 4
3. Eye exposure to sealant splash or acetic acid vapour causing serious irritation
Harm: Serious eye irritation (H319), lacrimation, conjunctivitis, corneal damage. Pressurised application increases splash risk. Permanent vision impairment possible without immediate irrigation.
3 × 4 = 12Mandatory BS EN 166 safety spectacles with side shields for all personnel within 3-metre radius. Full-face visor required for overhead application or when using pneumatic guns >3 bar pressure. Install plumbed eyewash station per BS EN 15154-2 within 10 seconds travel time. Conduct pre-task briefing on emergency eye irrigation procedure. Isolate work area with barriers and warning signage. Depressurise application gun before cartridge changes using controlled bleed valve.2 × 3 = 6
4. Manual handling of sealant cartridge boxes (typically 12-25 cartridges, 6-12 kg) causing musculoskeletal injury
Harm: Lower back strain, shoulder impingement, repetitive strain injury to hands/wrists from trigger operation. Cumulative trauma disorders from prolonged application work.
4 × 2 = 8Implement Manual Handling Operations Regulations 1992 assessment. Limit box weight to maximum 12 kg. Provide mechanical aids: trolleys, height-adjustable workbenches. Enforce team lift for loads >10 kg. Use pneumatic or battery-powered application guns to reduce hand force (trigger force <20 N). Rotate operatives every 2 hours. Provide task-specific manual handling training including neutral spine posture and load positioning. Conduct workstation ergonomic assessment per HSG60.2 × 2 = 4
5. Fire risk from storage of flammable solvent-based surface cleaners used in conjunction with sealant application
Harm: Fire, explosion, toxic fume inhalation (carbon monoxide, acrolein). Potential for rapid fire spread in storage areas containing multiple chemical products. Serious burns and fatalities.
2 × 5 = 10Segregate flammable cleaners in dedicated COSHH/flammable storage cabinet per BS EN 14470-1 (minimum 15-minute fire resistance). Limit quantities to single-shift requirement (<5 litres). Prohibit smoking and hot work within 10 metres - enforce permit-to-work per HSG250. Provide CO₂ or dry powder fire extinguishers (minimum 6 kg) within 10 metres. Ensure electrical equipment is ATEX-rated if solvent vapour concentration >10% LEL. Conduct weekly storage inspections and maintain COSHH inventory register. Train all operatives in emergency procedures and fire extinguisher use.1 × 4 = 4

3. Step-by-Step Safe Sequence of Operations & Hold-Points

1

Conduct pre-application COSHH assessment and atmospheric monitoring

Preparation and Risk Assessment

Review Safety Data Sheet (SDS) for Geocel The Works Trade Mate Silicone Sealant and confirm acetic acid WEL limits (10 ppm TWA, 15 ppm STEL). Inspect work area ventilation and measure baseline acetic acid vapour concentration using calibrated detector (must read <2 ppm before commencing). Verify LEV system operational and achieving minimum 10 air changes per hour using anemometer at extract points. Complete permit-to-work if confined space entry required. Confirm all operatives hold valid COSHH awareness training (refreshed within 12 months). Establish exclusion zone with barrier tape and warning signage ('Respiratory Irritant in Use - Authorised Personnel Only'). Position emergency eyewash station and spill kit within 10 metres. Conduct toolbox talk covering hazards, controls, and emergency procedures.

Critical Hold-Point: STOP: Do not proceed if baseline acetic acid vapour >2 ppm, LEV system inoperative, or atmospheric monitoring equipment uncalibrated/unavailable. Confined space entry without valid permit and standby person is prohibited and may result in fatal asphyxiation or acute respiratory injury.
2

Don mandatory PPE and verify fit and condition

Preparation and Risk Assessment

Wash hands and forearms with soap and water, then apply silicone-free barrier cream. Don inner nitrile gloves (BS EN ISO 374-1 Type B, 0.4mm minimum) ensuring cuffs overlap sleeves by minimum 50mm. Inspect gloves for tears, punctures, or degradation - discard if compromised. Don safety spectacles with side shields (BS EN 166) and verify optical clarity. If working overhead, in confined space, or if vapour monitoring indicates >5 ppm, don FFP3 filtering facepiece respirator (BS EN 149) and conduct positive/negative pressure fit check per manufacturer instructions. Verify safety footwear (BS EN ISO 20345 S3 SRC) is clean and slip-resistant. Confirm outer disposable gloves available for 30-minute change intervals. Buddy-check PPE with colleague before entering work area.

Critical Hold-Point: HOLD POINT: Respiratory protection is mandatory if atmospheric monitoring indicates acetic acid vapour ≥5 ppm (50% of 8-hour TWA WEL). Proceeding without FFP3 respirator in these conditions breaches COSHH Regulation 7 and may cause acute respiratory injury requiring medical intervention.
3

Prepare substrate surfaces ensuring adequate ventilation

Surface Preparation

Ensure LEV system running continuously throughout preparation phase. Clean application surfaces using lint-free cloth dampened with approved surface cleaner (check SDS for compatibility with silicone sealant). Remove old sealant, dirt, grease, and loose material using scraper and wire brush. Dispose of contaminated cloths in designated waste container (not general waste). If using solvent-based cleaner, verify flammable storage cabinet secured and no ignition sources within 10 metres. Allow surfaces to dry completely (typically 15-30 minutes depending on substrate porosity and ambient conditions). Conduct interim atmospheric monitoring - record acetic acid vapour concentration. If >5 ppm, increase ventilation or postpone application until levels reduce. Mask adjacent surfaces with low-tack tape if required to achieve clean sealant lines.

Critical Hold-Point: WARNING: Solvent-based cleaners may be flammable (flashpoint <23°C). Eliminate all ignition sources including smoking, hot work, and non-ATEX electrical equipment within 10-metre radius. Ensure fire extinguisher immediately accessible. Mixing incompatible chemicals may generate toxic vapours or violent reactions.
4

Apply silicone sealant using controlled dispensing technique with continuous monitoring

Application

Load Geocel The Works Trade Mate cartridge into application gun. Cut nozzle at 45° angle to achieve desired bead width (typically 5-10mm). Pierce inner seal using wire or spike. Apply steady, continuous bead at consistent speed (approximately 100-150mm per minute) maintaining 45° nozzle angle. For pneumatic guns, set air pressure to manufacturer specification (typically 3-6 bar) and verify pressure gauge reading before each cartridge. Conduct atmospheric monitoring every 30 minutes during application - record readings on permit-to-work or task sheet. If acetic acid vapour exceeds 10 ppm, cease work immediately, evacuate area, increase ventilation, and do not resume until levels <5 ppm. Take mandatory 15-minute fresh-air break every hour in designated clean area. Change outer disposable gloves every 30 minutes or immediately if contaminated. Depressurise pneumatic gun using bleed valve before cartridge changes.

Critical Hold-Point: CRITICAL: If acetic acid vapour concentration reaches 15 ppm (STEL), immediately cease work, evacuate all personnel, and do not re-enter until vapour <5 ppm confirmed by competent person with calibrated monitor. Exposure above STEL may cause acute bronchospasm and chemical pneumonitis requiring emergency medical treatment.
5

Manage curing period with enhanced ventilation and access control

Curing and Post-Application

Maintain LEV system operation for minimum 30 minutes post-application (60 minutes for confined spaces or applications >10 linear metres). Keep exclusion zone barriers and warning signage in place during initial cure period. Conduct final atmospheric monitoring at 30 minutes post-application - record reading and confirm <2 ppm before permitting unrestricted access. Remove masking tape within 10 minutes of application completion while sealant still wet to achieve clean edges. Do not touch or disturb sealant during cure period (typically 24 hours for full cure, skin formation 10-20 minutes depending on temperature and humidity). Ventilate area naturally for 24 hours if mechanical ventilation unavailable. Prohibit occupancy of confined spaces for minimum 2 hours post-application with continuous forced ventilation. Post 'Wet Sealant - Do Not Touch' signage at application locations.

Critical Hold-Point: CAUTION: Acetic acid vapour emission continues throughout cure period (typically 24-48 hours). Premature re-occupancy of confined or poorly ventilated spaces may expose personnel to irritant vapours above WEL. Asthmatics and individuals with pre-existing respiratory conditions must not enter area until vapour concentration confirmed <2 ppm.
6

Decontaminate equipment, dispose of waste, and complete documentation

Decontamination and Waste Disposal

Depressurise and dismantle application gun in well-ventilated area. Wipe external surfaces with damp cloth to remove sealant residue. Dispose of empty cartridges, contaminated cloths, and used gloves in designated hazardous waste container (EWC code 08 04 09* - waste adhesives and sealants containing organic solvents or other hazardous substances). Do not dispose in general waste or pour residues down drains. Seal waste container and label with contents, date, and hazard information. Arrange collection by licensed waste carrier - retain waste transfer notes for 2 years. Remove PPE in correct sequence: outer gloves, safety spectacles, respirator (if worn), inner gloves. Wash hands and forearms thoroughly with soap and water. Clean and store reusable PPE per manufacturer instructions. Complete COSHH assessment record sheet including atmospheric monitoring results, operatives exposed, duration of exposure, and any incidents or near-misses. File documentation in project COSHH register.

Critical Hold-Point: REGULATORY: Incorrect waste disposal breaches Environmental Protection Act 1990 and Hazardous Waste Regulations 2005. Silicone sealant waste is classified as hazardous waste and must be disposed via licensed carrier with consignment notes. Pouring residues down drains may cause environmental pollution and result in prosecution and unlimited fines.

Emergency Rescue, First Aid & Spill Protocol

**EMERGENCY CONTACTS:** Dial 999 for medical emergencies. Contact NHS 111 for non-emergency medical advice. Report to site First Aider and notify line manager immediately. **INHALATION:** Remove casualty to fresh air immediately. Keep warm and at rest in semi-recumbent position. If breathing is difficult, administer oxygen if trained and equipment available. If breathing stops, commence CPR if competent. Seek immediate medical attention - inform paramedics of acetic acid vapour exposure and provide SDS. Do not re-enter contaminated area without respiratory protection. **SKIN CONTACT:** Remove contaminated clothing immediately. Wash affected area with copious amounts of soap and lukewarm water for minimum 15 minutes. Do not use solvents or abrasive cleaners. If irritation, redness, or blistering develops, seek medical attention. Provide SDS to healthcare professional. Bag contaminated clothing for laundering or disposal - do not take home. **EYE CONTACT:** Irrigate eyes immediately with clean water or sterile eyewash solution for minimum 15 minutes, holding eyelids open. Remove contact lenses if present and easy to do so. Continue irrigation. Seek immediate medical attention from ophthalmologist or A&E - this is a medical emergency. Provide SDS. Do not rub eyes or apply ointments unless directed by medical professional. **INGESTION (UNLIKELY):** Do not induce vomiting. Rinse mouth thoroughly with water. Give small amounts of water to drink if casualty conscious. Seek immediate medical attention. Provide SDS to healthcare professional. Monitor for signs of gastrointestinal irritation or respiratory distress from aspiration. **SPILLAGE:** Evacuate area and establish 3-metre exclusion zone. Eliminate ignition sources if solvent cleaners involved. Ventilate area. Don appropriate PPE (gloves, eye protection, FFP2 respirator). Absorb liquid spillage with inert absorbent material (vermiculite, sand, proprietary absorbent granules). For acetic acid vapour release, neutralise with sodium bicarbonate solution (100g per litre water). Collect contaminated absorbent in hazardous waste container. Wash spill area with detergent and water. Dispose of waste via licensed carrier. **RIDDOR REPORTING:** Report to HSE under RIDDOR 2013 if exposure results in: (1) acute ill-health requiring medical treatment beyond first aid, (2) absence from work >7 consecutive days, (3) occupational disease diagnosis (e.g. occupational asthma, dermatitis). Report via www.hse.gov.uk/riddor or telephone 0345 300 9923 within required timeframes (fatal/specified injuries: immediate; >7 day absence: within 15 days; occupational disease: upon diagnosis).

4. UK HSE Compliance FAQs: Geocel The Works Trade Mate Silicone Sealant

5. Operative Toolbox Talk & Competent Person Sign-Off Register

Competent Person & Operative Declaration: By signing below, the Site Supervisor confirms this assessment has been adapted and verified for actual site conditions, and operatives confirm they have attended the pre-start Toolbox Talk for Geocel The Works Trade Mate Silicone Sealant and will follow the safe system of work.

Operative / Supervisor Name Trade / Role & CSCS No. Signature Date & Time
1. (Site Supervisor):     
2.     
3.     
4.     
5.     
6.     

Related UK Safety Templates & Risk Assessments