SafeSequence › UK Safety Template Library › Commercial Brand COSHH › Fosroc Conbextra GP Cementitious Grout & Nitobond EP Structural Epoxy
Reference UK COSHH Example • Commercial Brand COSHH

Fosroc Conbextra GP Cementitious Grout & Nitobond EP Structural Epoxy (COSHH Template & 5x5 Risk Assessment)

Under COSHH 2002 (as amended) and EH40/2005 Workplace Exposure Limits, Fosroc Conbextra GP cementitious grout (containing respirable crystalline silica) and Nitobond EP structural epoxy (GHS05 H318 serious eye damage, GHS07 H317 skin sensitisation, GHS09 aquatic hazard) require mandatory exposure control through local exhaust ventilation, wet-working methods, and isolation protocols to reduce inhalation and dermal contact risks from initial scores of 15–20 (high) to residual scores of 6–8 (medium-low). This COSHH assessment establishes UK statutory controls for mixing, application, and curing operations involving both products, ensuring compliance with HSE guidance HSG258 (Controlling Airborne Contaminants at Work) and the Construction (Design and Management) Regulations 2015. Competent persons must verify atmospheric monitoring for respirable crystalline silica (WEL 0.1 mg/m³ 8-hour TWA) and implement dermal exposure prevention for epoxy resin systems. Emergency procedures address alkali burns from wet cement and epoxy sensitisation incidents, with mandatory health surveillance for repeat users under COSHH Regulation 11.

Statutory FrameworkCOSHH 2002, EH40/2005 Silica & Epoxy Resin Controls (GHS05 H318, GHS07 H317, GHS09)
Classification**Fosroc Conbextra GP:** GHS05 (Corrosion) – H318 Causes serious eye damage; GHS07 (Harmful) – H315 Causes skin irritation, H335 May cause respiratory irritation. Contains Portland cement (CAS 65997-15-1) with respirable crystalline silica (CAS 14808-60-7). EH40/2005 WEL: Respirable crystalline silica 0.1 mg/m³ 8-hour TWA. **Fosroc Nitobond EP:** GHS05 (Corrosion) – H318 Causes serious eye damage; GHS07 (Harmful) – H317 May cause an allergic skin reaction, H315 Causes skin irritation; GHS09 (Environmental) – H411 Toxic to aquatic life with long-lasting effects. Contains epoxy resin (CAS 25068-38-6) and polyamine hardener. No assigned WEL but dermal sensitisation threshold applies. Both products classified under CLP Regulation (EC) 1272/2008 as amended in GB.
Required Plant / KitForced-air paddle mixer (electric, 110V site transformer, RCD-protected) for grout batching • Calibrated digital scales (0–25 kg capacity, ±10 g accuracy) for epoxy resin/hardener ratio verification • Stainless steel mixing paddle and clean polyethylene buckets (dedicated, labelled for epoxy use only) • Portable local exhaust ventilation (LEV) unit with H13 HEPA filtration (tested to HSG258 standards, current LEV examination certificate) • Personal air sampling pump and respirable dust cyclone (SKC or equivalent) for silica exposure monitoring to MDHS14/4 protocol
Site Sign-Off StatusRequires Competent Person Verification
Instant AI Customization or Free Blank Word (.doc) Download

Need this COSHH customized with your Company Name, Site Postcode & Nearest A&E Hospital?

Dictate your site specifics on your phone in 45 seconds to auto-compile a signed PDF—or download our free blank Word (.doc) shell below.

Auto-Fill via Voice / CLP (45s)

1. Mandatory Personal Protective Equipment (BS EN Standards)

BS EN ISO 374-1:2016 Type B (KPT), BS EN 374-4:2013
Nitrile chemical-resistant gloves (minimum 0.38 mm thickness, breakthrough time >480 minutes for epoxy resin)
Prevents dermal contact with alkaline cementitious slurry (pH 12–13) and epoxy resin/hardener causing skin sensitisation (H317) and irritation (H315). Mandatory under COSHH Regulation 7 for skin exposure prevention.
BS EN 140:1999 + BS EN 143:2021 (P3) or BS EN 12941:1998 (TH3 PAPR)
Full-face respirator with P3 particulate filter or powered air-purifying respirator (PAPR) with TH3 filter
Controls inhalation exposure to respirable crystalline silica during dry powder handling and mixing (EH40/2005 WEL 0.1 mg/m³). RPE assigned protection factor (APF) 20 minimum required where LEV alone cannot achieve adequate control.
BS EN 166:2001 (Grade 3 or 4 liquid splash, optical class 1)
Safety goggles with indirect ventilation or full-face shield
Protects against serious eye damage (H318) from alkaline cement splashes and epoxy resin contact. Mandatory for all mixing and pouring operations per COSHH hierarchy of control.
BS EN ISO 20345:2011 S3 (penetration-resistant, antistatic, energy absorption)
Safety boots with chemical-resistant sole and steel toecap
Prevents foot contact with corrosive wet grout and epoxy spillages. Provides mechanical protection during material handling and site operations under CDM 2015 and COSHH 2002.

2. 5×5 Hazard Risk Assessment Matrix (HASAWA 1974 / MHSWR 1999)

Identified Hazard & HarmInitial Risk (L×S)Mandatory Engineering, Isolation & Procedural ControlsResidual Risk
1. Inhalation of respirable crystalline silica (RCS) during dry powder handling and mixing of Conbextra GP grout
Harm: Silicosis (irreversible lung fibrosis), chronic obstructive pulmonary disease (COPD), lung cancer (IARC Group 1 carcinogen). Latency period 10–20 years. Fatal occupational lung disease.
4 × 5 = 20Engineering: Use pre-bagged grout in controlled mixing area with portable LEV (minimum 1.5 m/s capture velocity at source, tested to HSG258). Wet-working methods: dampen powder before mixing. Isolation: Restrict access to mixing zone, erect physical barriers. Atmospheric monitoring: Personal air sampling to MDHS14/4 protocol, compare to EH40/2005 WEL 0.1 mg/m³. RPE: Mandatory P3 or PAPR (APF 20+). Health surveillance: Respiratory questionnaire and spirometry every 2 years per HSG264.3 × 2 = 6
2. Skin sensitisation and allergic contact dermatitis from epoxy resin and polyamine hardener in Nitobond EP
Harm: Irreversible Type IV hypersensitivity reaction (H317). Chronic eczema, blistering, occupational dermatitis requiring permanent exclusion from epoxy work. Reportable under RIDDOR if work-related skin disease confirmed.
5 × 3 = 15Elimination: Pre-mixed cartridge systems where practicable. Substitution: Lower-sensitising epoxy formulations (consult supplier). Engineering: Closed mixing systems, drip trays, spill containment. Dermal exposure prevention: Mandatory nitrile gloves (BS EN ISO 374-1 Type B, >480 min breakthrough), barrier cream (pre-work), emollient (post-work). Hygiene: Dedicated wash station, no dry wiping, skin checks before breaks. Health surveillance: Dermatological assessment every 12 months, immediate reporting of rashes.4 × 2 = 8
3. Serious eye damage (H318) from alkaline cement slurry splash or epoxy resin contact
Harm: Corneal burns, permanent vision impairment, blindness. Alkali burns penetrate deeper than acid burns, causing progressive tissue damage. Emergency irrigation required within 60 seconds.
3 × 5 = 15Engineering: Splash guards on mixers, controlled pouring techniques, secondary containment. PPE: Mandatory BS EN 166 Grade 3/4 goggles or full-face shield during all mixing, pouring, and application. Emergency: Eyewash station (BS EN 15154-2:2006) within 10 metres, 15-minute continuous irrigation protocol. Training: Demonstrate emergency eyewash procedure, buddy system for lone workers. Supervision: Competent person verifies eye protection compliance before work commences.2 × 3 = 6
4. Manual handling of 25 kg grout bags and epoxy component containers causing musculoskeletal injury
Harm: Acute back strain, chronic lower back pain, shoulder and knee injuries. Cumulative trauma from repetitive lifting. Reportable under RIDDOR if >7 days incapacity.
5 × 3 = 15Elimination: Mechanical handling aids (sack trolley, pallet truck, hoist). Task design: Two-person lift for >20 kg loads, reduce carry distances to <5 metres. Training: Manual Handling Operations Regulations 1992 training, demonstrate correct lifting technique (neutral spine, power zone). Workstation: Adjust mixing platform height to waist level, anti-fatigue matting. Supervision: Pre-task brief on load weights and team-lift requirements. Health surveillance: Pre-placement musculoskeletal screening, annual review.4 × 2 = 8
5. Exothermic reaction during epoxy curing generating heat and fumes in confined or poorly ventilated spaces
Harm: Thermal burns from hot epoxy mass (up to 80°C in bulk mixes), inhalation of amine vapours causing respiratory irritation, headache, nausea. Risk of fire if curing in enclosed container.
3 × 4 = 12Engineering: Natural or mechanical ventilation (minimum 5 air changes/hour in enclosed spaces). Process control: Limit batch size to manufacturer's recommendations (typically <5 kg for Nitobond EP), use shallow pour depths (<25 mm) to dissipate heat. Isolation: Prohibit curing in sealed containers, remove lids immediately after mixing. Monitoring: Infrared thermometer checks during cure cycle, abort if >60°C. Emergency: Fire extinguisher (CO₂ or dry powder) within 5 metres, evacuation plan for confined spaces. Training: Recognise signs of runaway exotherm (smoke, strong odour, rapid temperature rise).2 × 3 = 6

3. Step-by-Step Safe Sequence of Operations & Hold-Points

1

Pre-Work COSHH Briefing and Atmospheric Monitoring Setup

Preparation and Risk Assessment

Competent person conducts toolbox talk covering hazards (silica, epoxy sensitisation, eye damage), emergency procedures, and PPE requirements. Verify current Safety Data Sheets (SDS) for both products on-site. Establish exclusion zone (minimum 3-metre radius) with barriers and signage ('COSHH Controlled Area – Authorised Personnel Only – RPE Mandatory'). Set up portable LEV unit, verify airflow with anemometer (≥1.5 m/s capture velocity). If baseline silica exposure unknown, deploy personal air sampling pump on representative worker (MDHS14/4 protocol, 4-hour sample minimum). Confirm eyewash station operational (weekly flush log checked). Inspect all PPE for damage (gloves for punctures, respirator fit-test current within 3 years).

Critical Hold-Point: STOP: Do not proceed if LEV examination certificate expired (14-month maximum interval per HSG258) or if any worker reports existing skin rash/respiratory symptoms. Refer to Occupational Health before commencing epoxy work.
2

Controlled Grout Batching with Silica Exposure Minimisation

Material Handling and Mixing – Conbextra GP Grout

Don full PPE (P3 respirator, nitrile gloves, goggles, coveralls). Position LEV inlet within 300 mm of mixing bucket. Use two-person lift for 25 kg grout bags. Cut bag open slowly at low level to minimise dust release. Dampen powder surface with water spray before tipping into bucket (wet-working method). Add measured water per manufacturer's ratio (typically 3.5–4.0 litres per 25 kg bag) using calibrated container. Mix with electric paddle mixer (110V, RCD-protected) at low speed (400–600 rpm) for 3 minutes. Avoid over-mixing which re-entrains dust. Keep mixer paddle submerged. Dispose of empty bags into sealed waste sack immediately (do not shake out residue). Record batch time and water ratio on job sheet.

Critical Hold-Point: HOLD POINT: Verify respirator seal check (positive/negative pressure test) before opening grout bag. If dust cloud visible despite LEV, stop work and increase ventilation or reduce batch size. Silica exposure is cumulative – minimise time in dust zone.
3

Epoxy Resin/Hardener Mixing with Dermal Exposure Prevention

Material Handling and Mixing – Nitobond EP Epoxy

Work in well-ventilated area (outdoor or 5+ air changes/hour). Lay absorbent spill mat under mixing area. Weigh epoxy resin (Part A) and hardener (Part B) using calibrated scales to exact manufacturer's ratio (typically 2:1 by weight for Nitobond EP – verify on SDS). Pour resin into clean, dry bucket first, then add hardener slowly to avoid splashing. Use dedicated stainless steel paddle (never re-use for food). Mix thoroughly for 2–3 minutes, scraping sides and base to ensure homogeneous blend. Check for colour uniformity (no streaks). Limit batch size to maximum 5 kg to control exothermic reaction. Transfer mixed epoxy to application area immediately (pot life typically 30–45 minutes at 20°C). Seal component containers immediately after use to prevent moisture ingress and skin contact.

Critical Hold-Point: STOP: Never mix epoxy in direct sunlight or near heat sources (accelerates exotherm). If skin contact occurs, do NOT use solvents – wash immediately with soap and water for 15 minutes. Remove contaminated gloves carefully (peel inside-out) and dispose as hazardous waste. Change gloves between batches to prevent sensitiser build-up.
4

Controlled Pouring and Placement with Splash Prevention

Application and Placement

For grout: Pour mixed Conbextra GP from low height (<300 mm) into formwork or void, using funnel or chute to direct flow and minimise splashing. Maintain continuous pour to avoid cold joints. Vibrate or rod to remove air pockets, keeping face away from surface. For epoxy: Apply Nitobond EP to prepared substrate using notched trowel or brush, working in thin layers (<5 mm per coat). Avoid over-application which increases exotherm risk. Ensure adequate ventilation throughout application. Keep mixed material in shallow trays (not deep buckets) to dissipate heat. Monitor ambient temperature (epoxy cures faster above 25°C). Restrict access to application area – maintain 3-metre exclusion zone. Provide runner/banksman to fetch additional materials so applicator remains in controlled zone.

Critical Hold-Point: HOLD POINT: If epoxy batch becomes hot to touch (>40°C) or emits strong amine odour, evacuate area immediately and allow to cure in open air away from combustibles. Do not add water to hot epoxy (violent reaction risk). For grout, avoid skin contact with wet alkaline slurry (pH 12–13) – irrigate immediately if contact occurs.
5

Post-Application Monitoring and Exposure Control During Cure

Curing and Monitoring

Erect barriers and 'Wet Cement/Epoxy Curing – No Access' signage around work area. For epoxy, monitor curing mass temperature with infrared thermometer at 15-minute intervals for first hour (record on job sheet). If temperature exceeds 60°C, increase ventilation and apply cooling (fan, not water). Maintain exclusion zone until epoxy fully cured (typically 24 hours at 20°C, verify on SDS). For grout, protect from rapid drying (cover with polythene or apply curing membrane) per manufacturer's instructions. Prohibit grinding, cutting, or drilling of cured material for minimum 7 days (generates silica dust requiring separate COSHH assessment). Ventilate area continuously during cure period to disperse amine vapours. Post competent person to enforce exclusion zone if work continues nearby.

Critical Hold-Point: STOP: Do not apply heat (e.g. blow heaters) to accelerate epoxy cure – increases fire risk and amine vapour release. If worker reports eye irritation, headache, or respiratory symptoms during cure period, evacuate immediately and seek medical advice (possible amine vapour exposure). Record incident in site accident book.
6

Safe Clean-Up, PPE Removal, and Hazardous Waste Management

Decontamination and Waste Disposal

Before removing PPE, decontaminate tools and equipment: scrape excess material into waste container, wash with water (grout) or approved epoxy cleaner (never solvents on skin). Dispose of contaminated materials as hazardous waste (EWC code 08 04 09* for epoxy waste, 10 13 06 for cement waste) via licensed carrier – retain waste transfer notes. Remove PPE in correct sequence: gloves (peel inside-out, avoid touching exterior), goggles, respirator (store in clean sealed bag), coveralls (roll inwards). Wash hands and forearms thoroughly with soap and water, apply emollient cream. Inspect skin for redness, itching, or rash – report immediately to supervisor if present. Clean and store reusable PPE (respirator face-piece, goggles) per manufacturer's instructions. Decontaminate LEV unit (wipe pre-filter, check HEPA integrity). Complete COSHH work record: products used, quantities, exposure duration, atmospheric monitoring results, any incidents.

Critical Hold-Point: HOLD POINT: Never wash epoxy-contaminated gloves or tools in welfare facilities (contaminates sinks, spreads sensitiser). Use dedicated decontamination area with separate drainage or absorbent disposal. If skin irritation develops within 48 hours post-exposure, seek Occupational Health review – may indicate sensitisation requiring permanent exclusion from epoxy work (reportable under RIDDOR Regulation 8 if confirmed occupational dermatitis).

Emergency Rescue, First Aid & Spill Protocol

**Eye Contact (H318 Serious Eye Damage):** Immediately irrigate affected eye(s) with clean water for minimum 15 minutes using eyewash station (BS EN 15154-2:2006). Hold eyelids open, rotate eyeball to flush all surfaces. Remove contact lenses if present and easy to do. Continue irrigation during transport to A&E. Call 999 or arrange blue-light ambulance for alkali or epoxy eye burns – specify chemical name (Portland cement or epoxy resin). Do NOT use neutralising agents. Preserve product SDS for medical staff. **Skin Contact (H315 Irritation, H317 Sensitisation):** Remove contaminated clothing immediately. Wash affected area with soap and lukewarm water for 15 minutes – do NOT use solvents, thinners, or abrasive cleaners (drives chemicals deeper). Pat dry gently. Apply emollient cream. If redness, blistering, or itching develops, seek medical advice same day – inform doctor of epoxy sensitisation risk. For large-area cement burns (pH 12–13), treat as chemical burn and seek A&E assessment. **Inhalation (Silica Dust, Amine Vapours):** Move casualty to fresh air immediately. Loosen tight clothing. If breathing difficult, place in comfortable position (usually sitting upright). Monitor breathing and consciousness. Call 999 if symptoms persist (coughing, wheezing, chest tightness). Administer oxygen if trained and available. Provide SDS to paramedics. Do NOT induce vomiting. **Ingestion (Unlikely but possible via hand-to-mouth transfer):** Do NOT induce vomiting (alkali burns to oesophagus). Rinse mouth with water, spit out – do not swallow. Give small sips of water if conscious. Call 999 or NHS 111 immediately. Provide product SDS. **Spillage:** Small spills (<1 litre): Absorb with vermiculite or sand, sweep into labelled hazardous waste container. Ventilate area. Large spills: Evacuate area, prevent entry to drains/watercourses (GHS09 aquatic hazard), call Environment Agency Incident Hotline 0800 807060 if environmental release. Contain with absorbent booms, recover as hazardous waste. **Fire:** Epoxy is combustible when curing in bulk. Use CO₂, dry powder, or foam extinguisher. Wear BA if smoke present (toxic amine fumes). Cool containers with water spray from safe distance. Evacuate if runaway exotherm suspected (rapid temperature rise, dense smoke).

4. UK HSE Compliance FAQs: Fosroc Conbextra GP Cementitious Grout & Nitobond EP Structural Epoxy

5. Operative Toolbox Talk & Competent Person Sign-Off Register

Competent Person & Operative Declaration: By signing below, the Site Supervisor confirms this assessment has been adapted and verified for actual site conditions, and operatives confirm they have attended the pre-start Toolbox Talk for Fosroc Conbextra GP Cementitious Grout & Nitobond EP Structural Epoxy and will follow the safe system of work.

Operative / Supervisor Name Trade / Role & CSCS No. Signature Date & Time
1. (Site Supervisor):     
2.     
3.     
4.     
5.     
6.     

Related UK Safety Templates & Risk Assessments