Under COSHH 2002 Regulation 6, DSEAR 2002 Regulation 6, and EH40/2005 Workplace Exposure Limits, employers must prevent or adequately control exposure to volatile organic compounds (VOCs) in Bostik Evo-Stik Impact Contact Adhesive and Gripfill Solvent-Borne Gap Filler (classified GHS02 flammable, GHS07 harmful, GHS09 environmental hazard). Mandatory engineering controls include local exhaust ventilation (LEV) achieving ≥10 air changes/hour, elimination of ignition sources within ATEX-zoned areas, and respiratory protective equipment (RPE) where 8-hour TWA exceeds 50% WEL. Target residual risk: ≤6 (tolerable) through hierarchy of control implementation, atmospheric monitoring, and health surveillance per HSG258 guidance.
| Identified Hazard & Harm | Initial Risk (L×S) | Mandatory Engineering, Isolation & Procedural Controls | Residual Risk |
|---|---|---|---|
| 1. Inhalation of volatile organic compound (VOC) vapours (hydrocarbons, acetone) in confined/poorly ventilated spaces Harm: Acute: Dizziness, headache, nausea, respiratory irritation, narcotic effects. Chronic: Central nervous system depression, liver/kidney damage, occupational asthma (COSHH Regulation 7 health surveillance trigger) | 4 × 4 = 16 | Engineering: Install/verify LEV system achieving ≥10 air changes/hour with capture velocity ≥1 m/s at source (HSG258). Administrative: Atmospheric monitoring pre-work and every 2 hours; work permit for confined spaces per L101. RPE: Mandatory A2P3 half-mask (APF 20) or PAPR (APF 40) where monitoring indicates >600 mg/m³ (50% WEL). Rotate operatives every 2 hours to limit exposure duration. Health surveillance: Annual respiratory questionnaire and spirometry per HSG61. | 2 × 2 = 4 |
| 2. Fire/explosion risk from flammable solvent vapours (flash point -18°C to 32°C) in presence of ignition sources Harm: Catastrophic fire/explosion causing severe burns (full-thickness), blast injuries, structural damage, and multiple fatalities; RIDDOR-reportable dangerous occurrence under Regulation 3(1) | 3 × 5 = 15 | DSEAR Assessment: Classify work area as Zone 2 (vapour cloud possible <10% LEL). Elimination: Remove all ignition sources (hot work, smoking, non-ATEX electrical equipment) within 10m radius. Substitution: Consider water-borne adhesives where technically feasible. Engineering: Bonding/earthing of metal containers (resistance <10Ω); explosion-relief venting. Administrative: Hot work permit system with 60-minute fire watch post-completion. Store <50 litres in DSEAR-compliant flammable cabinet (30-minute fire rating). Emergency: CO₂/foam extinguishers (not water) within 10m; evacuation plan rehearsed quarterly. | 2 × 3 = 6 |
| 3. Skin contact causing irritant contact dermatitis, defatting of skin, and potential sensitisation Harm: Acute: Erythema, cracking, painful fissures on hands/forearms. Chronic: Occupational dermatitis requiring medical treatment, potential long-term sensitisation preventing future solvent work (COSHH Regulation 11 health record retention 40 years) | 5 × 2 = 10 | Hierarchy: Eliminate hand contact via automated dispensing systems or long-handled applicators. Engineering: Provide touchless soap dispensers and moisturising stations at exit points. PPE: Nitrile gloves (0.38mm, EN 374 Type A) changed every 2 hours or immediately if contaminated; double-gloving for extended tasks. Administrative: Skin surveillance programme (visual inspection monthly); pre-employment baseline skin assessment. Prohibit barrier creams as primary control (COSHH ACoP L5 paragraph 131). Emergency: Wash contaminated skin immediately with soap and water for ≥15 minutes; occupational health referral if dermatitis suspected. | 3 × 2 = 6 |
| 4. Accidental ingestion during hand-to-mouth contact or contaminated food/drink in work area Harm: Acute gastrointestinal irritation, vomiting, chemical pneumonitis if aspirated into lungs (potentially fatal), systemic toxicity requiring hospital admission | 2 × 4 = 8 | Administrative: Enforce strict hygiene protocol - no eating/drinking/smoking in application areas (signage per Safety Signs Regulations 1996). Designate separate clean mess facility ≥10m from work zone. Mandatory handwashing before breaks (supervised compliance checks). Training: Toolbox talk on aspiration hazard (do NOT induce vomiting if swallowed). Engineering: Provide lockable storage for food/drink outside controlled area. Emergency: If swallowed, rinse mouth and seek immediate medical attention with SDS Section 4; position casualty in recovery position if vomiting to prevent aspiration. | 1 × 3 = 3 |
| 5. Environmental release of VOCs and aquatic-toxic solvents (GHS09) to drains, watercourses, or soil Harm: Prosecution under Environmental Protection Act 1990 and Environmental Permitting Regulations 2016; aquatic ecosystem damage; contaminated land remediation costs (£10k-£500k+); reputational damage and loss of environmental certification (ISO 14001) | 3 × 3 = 9 | Engineering: Bunded work area with impermeable sheeting and spill containment capacity ≥110% of largest container. Install drain covers/seals before work commences. Provide spill kit (absorbent pads, vermiculite, disposal bags) within 5m. Administrative: Appoint trained spill response operative; emergency contact for Environment Agency (0800 807060) displayed. Waste: Classify as hazardous waste (EWC 08 04 09* - waste adhesives containing dangerous substances); consign via registered carrier with hazardous waste consignment note. Prohibit washing equipment in sinks/drains. Storage: Secondary containment (110% capacity) for bulk containers; weekly integrity inspections logged. | 1 × 3 = 3 |
Obtain valid permit-to-work signed by competent person (NEBOSH/NVQ Level 6 or equivalent). Verify LEV system operational (manometer reading within green zone, last TExT certificate <14 months old). Conduct baseline atmospheric monitoring using calibrated VOC monitor (zero and span check completed); record readings at breathing zone height. Confirm flammable vapour concentration <10% LEL; if ≥10% LEL, halt work and increase ventilation. Establish DSEAR Zone 2 boundary (10m radius) with warning signs per Safety Signs Regulations 1996. Isolate/lock-off electrical supplies not ATEX-rated; issue LOTO tags to authorised operative only. Confirm emergency equipment in place: CO₂ extinguisher, spill kit, eyewash station, first aider contact details displayed.
Perform hand hygiene and visual skin inspection (record any pre-existing cuts/dermatitis in daily log). Don chemical-resistant coveralls (Type 6) ensuring cuffs sealed. Fit nitrile gloves (EN 374 Type A, 0.38mm) over coverall sleeves; check for tears/punctures. Don safety footwear (S3 SRC FO anti-static). Conduct negative/positive pressure seal check on A2P3 half-mask respirator per manufacturer instructions (HSG53 protocol); if seal fails, adjust straps or change facepiece size. Don safety spectacles (EN 166 Class 1) ensuring compatibility with respirator. Confirm RPE filter cartridge within use-by date and <6 months since opening (record date opened on cartridge). Designate clean/dirty zones; establish decontamination protocol before breaks.
Place container in bunded tray (≥110% capacity) positioned directly beneath LEV hood (capture velocity ≥1 m/s verified with smoke tube test). Bond container to earth point using crocodile clip and verify continuity <10Ω with multimeter. Open lid slowly using non-sparking bronze tool to allow pressure equalisation (vapour release expected). If using Gripfill cartridge gun, pierce seal in well-ventilated area with gun nozzle pointed away from body/face. Decant only the quantity required for immediate use (maximum 500ml) into secondary metal container; reseal primary container immediately. Wipe any spillage on exterior with solvent-resistant cloth and place in sealed metal waste bin. Maintain continuous atmospheric monitoring; if VOC reading exceeds 600 mg/m³ (50% WEL), increase ventilation or reduce work rate.
Apply adhesive in thin, even coats using non-sparking spatula or Gripfill gun at low pressure to minimise aerosol generation. Work in sections ≤2m² to limit open surface area and vapour release. Maintain face position upwind/upstream of LEV airflow; never position head directly over application point. For contact adhesive (Evo-Stik Impact), allow flash-off time (5-15 minutes per manufacturer SDS) before bonding surfaces; during flash-off, vapour release peaks - maintain maximum ventilation. Rotate operatives every 2 hours (record rotation times on permit). Conduct atmospheric monitoring every 30 minutes during application; if TWA trending toward WEL, implement additional controls (increase ventilation, reduce application rate, introduce second LEV unit). Prohibit use of fans that may spread vapours toward ignition sources or unprotected personnel.
Place all contaminated applicators, rags, and PPE in designated metal waste container with self-closing lid (spontaneous combustion risk from solvent-soaked materials). Seal container and label 'Hazardous Waste - EWC 08 04 09* - Flammable VOCs'. Store in external bunded area away from buildings pending collection by licensed carrier (consignment note required). Clean non-disposable tools with minimal solvent in bunded area; allow cleaning rags to dry flat (not bunched) in ventilated area before disposal. Decontaminate work area with damp cloth (not dry sweeping which generates dust/vapour). Conduct final atmospheric monitoring at multiple heights (vapours heavier than air); record readings. Confirm VOC concentration <10% baseline before declaring area safe for unrestricted access. Remove DSEAR boundary signs only after clearance confirmed.
Record total exposure duration, peak VOC readings, and average TWA on COSHH exposure log (retain 40 years per Regulation 11). Operative completes post-shift health questionnaire (symptoms: headache, dizziness, nausea, skin irritation, respiratory issues). Supervisor reviews questionnaire; any positive responses trigger occupational health referral within 48 hours. Inspect operative's hands/forearms for signs of dermatitis; photograph any abnormalities for health record. Clean and store RPE per manufacturer instructions; record filter cartridge usage hours (discard after 40 hours use or 6 months, whichever sooner). Return permit-to-work with all monitoring data and incident/near-miss reports. Update COSHH assessment if any control failures identified; communicate lessons learned in next toolbox talk. Schedule LEV TExT if performance concerns noted.
**INHALATION (Priority 1):** Remove casualty to fresh air immediately; loosen tight clothing. If breathing is difficult, administer oxygen (if trained and equipment available). If breathing stops, commence CPR and call 999 requesting paramedic attendance (state 'solvent inhalation, possible chemical pneumonitis'). Do NOT leave casualty unattended - VOC intoxication can cause delayed respiratory depression. Monitor consciousness level using AVPU scale. Provide SDS Section 4 to paramedics. Report to HSE under RIDDOR if hospitalisation >24 hours. **SKIN CONTACT:** Remove contaminated clothing immediately (double-bag as hazardous waste). Wash affected area with soap and lukewarm water for minimum 15 minutes (not cold water which closes pores). Do NOT use solvents/thinners to clean skin (increases absorption). Apply emollient cream (not barrier cream). If irritation persists or dermatitis develops, refer to occupational health within 48 hours. Photograph affected area for health record. Launder contaminated clothing separately before reuse. **EYE CONTACT (Priority 1):** Irrigate eyes immediately at emergency eyewash station for minimum 15 minutes, holding eyelids open. Remove contact lenses if present and easy to do. Continue irrigation while arranging urgent medical assessment (ophthalmology referral if corneal damage suspected). Do NOT rub eyes. Provide SDS Section 4 to treating clinician. Eye injuries from solvents are RIDDOR-reportable if result in incapacity for normal work >7 days. **INGESTION (Priority 1):** Do NOT induce vomiting (aspiration into lungs can be fatal). Rinse mouth thoroughly with water (do not swallow). Give small sips of water if conscious and able to swallow. Call 999 immediately and request paramedic attendance stating 'hydrocarbon solvent ingestion, aspiration risk'. Position casualty in recovery position if vomiting to protect airway. Provide SDS and container label to paramedics. Hospital assessment mandatory even if asymptomatic (delayed chemical pneumonitis can develop 6-24 hours post-ingestion). **FIRE/EXPLOSION:** Activate fire alarm and evacuate per emergency plan. Call 999 stating 'flammable solvent fire'. Use CO₂, foam, or dry powder extinguishers only (water will spread fire). If fire involves >5 litres or cannot be controlled within 60 seconds, evacuate and await fire brigade. Treat burns per first aid protocol (cool with running water 20 minutes, cover with cling film, do not burst blisters). All fires involving flammable substances are RIDDOR-reportable as dangerous occurrences under Regulation 3(1). **SPILL >1 LITRE:** Evacuate area and establish 10m exclusion zone. Eliminate ignition sources. Ventilate area. Trained spill response operative (wearing full PPE + RPE) to absorb with vermiculite/sand, never water. Contain with absorbent booms to prevent drain entry. Collect waste in sealed metal container labelled hazardous waste. If spill enters drains/watercourses, immediately notify Environment Agency 24-hour hotline 0800 807060 (legal duty under Environmental Permitting Regulations 2016). Decontaminate area and conduct atmospheric monitoring before re-entry.
Competent Person & Operative Declaration: By signing below, the Site Supervisor confirms this assessment has been adapted and verified for actual site conditions, and operatives confirm they have attended the pre-start Toolbox Talk for Bostik Evo-Stik Impact Contact Adhesive & Gripfill Solvent-Borne Gap Filler and will follow the safe system of work.
| Operative / Supervisor Name | Trade / Role & CSCS No. | Signature | Date & Time |
|---|---|---|---|
| 1. (Site Supervisor): | |||
| 2. | |||
| 3. | |||
| 4. | |||
| 5. | |||
| 6. |