SafeSequence › UK Safety Template Library › Commercial Brand COSHH › Everbuild Tecnic PinkGrip Solvent-Free Adhesive
Reference UK COSHH Example • Commercial Brand COSHH

Everbuild Tecnic PinkGrip Solvent-Free Adhesive (COSHH Template & 5x5 Risk Assessment)

Under COSHH 2002 (as amended), REACH, CLP Regulation, EH40 WELs, and HSG258 Controlling Airborne Contaminants at Work, employers must assess exposure to Everbuild Tecnic PinkGrip Solvent-Free Adhesive, implement engineering controls and local exhaust ventilation to prevent inhalation of vapours, ensure adequate skin protection against sensitisation, and reduce residual risk to tolerable levels through hierarchy of control measures. This COSHH assessment provides comprehensive hazard identification, exposure control strategies, mandatory PPE specifications, and emergency procedures for safe handling, application, and storage of this polymer-based construction adhesive. The product contains polymeric diphenylmethane diisocyanate (pMDI) which may cause respiratory sensitisation and skin irritation requiring strict exposure prevention. All operatives must receive competent instruction, training, and health surveillance where exposure cannot be adequately controlled. Workplace exposure limits must not be exceeded and air monitoring conducted where significant exposure risk exists.

Statutory FrameworkCOSHH 2002 (as amended), EH40 WELs, REACH, CLP Regulation, HSG258 Controlling Airborne Contaminants at Work
ClassificationEverbuild Tecnic PinkGrip Solvent-Free Adhesive is classified under CLP Regulation (EC) No 1272/2008. GHS Classification: Skin Sensitisation Category 1 (H317: May cause an allergic skin reaction), Respiratory Sensitisation Category 1 (H334: May cause allergy or asthma symptoms or breathing difficulties if inhaled), Eye Irritation Category 2 (H319: Causes serious eye irritation). Signal Word: DANGER. Hazard Pictograms: GHS07 (Exclamation Mark), GHS08 (Health Hazard). Contains polymeric diphenylmethane diisocyanate (pMDI) CAS 9016-87-9. Not classified as dangerous goods for transport under ADR/RID/IMDG/ICAO. REACH Registration: Substance registered under REACH. UFI Code available on product label for emergency response. Precautionary Statements: P261 (Avoid breathing dust/fume/gas/mist/vapours/spray), P280 (Wear protective gloves/protective clothing/eye protection/face protection), P284 (In case of inadequate ventilation wear respiratory protection), P304+P340 (IF INHALED: Remove person to fresh air and keep comfortable for breathing), P342+P311 (If experiencing respiratory symptoms: Call a POISON CENTER/doctor).
Required Plant / KitSkeleton gun applicator or pneumatic dispensing equipment suitable for 350ml cartridges • Local Exhaust Ventilation (LEV) system with minimum capture velocity 0.5 m/s at point of application, tested and examined every 14 months per HSG258 • Mechanical ventilation system providing minimum 5-10 air changes per hour in enclosed spaces • Impervious waste disposal containers with sealed lids for contaminated materials and empty cartridges • Emergency eyewash station compliant with BS EN 15154-2:2006, located within 10 seconds travel time from work area
Site Sign-Off StatusRequires Competent Person Verification
Instant AI Customization or Free Blank Word (.doc) Download

Need this COSHH customized with your Company Name, Site Postcode & Nearest A&E Hospital?

Dictate your site specifics on your phone in 45 seconds to auto-compile a signed PDF—or download our free blank Word (.doc) shell below.

Auto-Fill via Voice / CLP (45s)

1. Mandatory Personal Protective Equipment (BS EN Standards)

BS EN 374-1:2016 and BS EN ISO 374-5:2016 Type B
Nitrile gloves minimum 0.4mm thickness
Protection against skin sensitisation from pMDI and polymer contact. Nitrile provides superior chemical resistance to isocyanates. Replace immediately if contaminated or damaged.
BS EN 166:2001 Class 1 Optical Quality, marking 3-1.2 1 F
Safety spectacles with side shields or full-face visor
Mandatory protection against eye irritation (H319) from splashes and aerosol mist during dispensing and application. Must provide lateral protection.
BS EN ISO 13982-1:2004 (Type 5) and BS EN 13034:2005+A1:2009 (Type 6)
Disposable coveralls Type 5/6 with elasticated cuffs and ankles
Prevent skin contact and sensitisation. Protects against airborne particles and liquid aerosols. Dispose of contaminated garments safely; do not launder or reuse.
BS EN 140:1999 with BS EN 14387:2004+A1:2008 (A1) and BS EN 143:2000 (P2)
Half-mask respirator with combined A1P2 filters or supplied-air respirator in confined spaces
Respiratory protection against isocyanate vapours and aerosols where LEV inadequate or during confined space work. Mandatory for respiratory sensitisation risk (H334). Face-fit testing required per HSG53.

2. 5×5 Hazard Risk Assessment Matrix (HASAWA 1974 / MHSWR 1999)

Identified Hazard & HarmInitial Risk (L×S)Mandatory Engineering, Isolation & Procedural ControlsResidual Risk
1. Respiratory sensitisation from inhalation of pMDI vapours and aerosol mist during adhesive dispensing and application
Harm: Occupational asthma, irreversible respiratory sensitisation, breathing difficulties, wheezing, chest tightness. Once sensitised, even trace exposures trigger severe reactions. Long-term lung damage and permanent disability possible.
4 × 4 = 16Install and maintain LEV system per HSG258 with capture velocity ≥0.5 m/s at emission point. Conduct thorough examination and testing every 14 months by competent person. Implement health surveillance programme including pre-placement and periodic respiratory questionnaires and spirometry. Enforce mandatory RPE (A1P2 minimum) where LEV inadequate. Restrict access to trained, authorised personnel only. Monitor workplace air per HSG173 to verify exposure below WEL. Implement permit-to-work for confined space applications. Provide emergency respiratory support equipment.2 × 3 = 6
2. Skin sensitisation and allergic contact dermatitis from direct skin contact with uncured adhesive containing pMDI
Harm: Allergic skin reactions, dermatitis, eczema, skin rashes, itching, blistering. Sensitisation is permanent; subsequent exposures cause increasingly severe reactions. May require job change if sensitised.
4 × 3 = 12Enforce strict no-skin-contact policy. Mandatory nitrile gloves (≥0.4mm) per BS EN 374-1:2016 changed every 2 hours or immediately if contaminated. Provide barrier skin creams (pre-work) and after-work skin conditioning creams. Install washing facilities with warm water, mild soap, and disposable towels within immediate work area. Prohibit use of solvents for skin cleaning. Implement skin surveillance programme with regular inspections. Provide impervious coveralls Type 5/6. Train operatives in correct glove donning/doffing to prevent contamination. Isolate contaminated clothing immediately.2 × 2 = 4
3. Serious eye irritation from splashes, aerosol mist, or accidental contact during cartridge loading or application
Harm: Serious eye irritation, pain, redness, watering, temporary vision impairment. Risk of corneal damage if not immediately irrigated. Potential for permanent eye damage with delayed treatment.
3 × 3 = 9Mandatory safety spectacles with side shields (BS EN 166:2001 Class 1) or full-face visor for all personnel within 3 metres of application. Install emergency eyewash station per BS EN 15154-2:2006 within 10 seconds travel time. Train all operatives in emergency eyewash procedures. Implement safe systems of work for cartridge changing to minimise splash risk. Use low-pressure dispensing equipment to reduce aerosol generation. Prohibit overhead application without additional face protection. Ensure adequate lighting (minimum 500 lux) to prevent accidental contact. Supervise inexperienced operatives.2 × 2 = 4
4. Fire risk from storage of flammable cartridges and generation of heat during curing in bulk applications or confined spaces
Harm: Fire, smoke inhalation, burns, property damage. Exothermic curing reaction in bulk can generate sufficient heat to ignite combustible materials. Smoke from burning adhesive releases toxic isocyanate decomposition products.
2 × 4 = 8Store cartridges in cool, dry, well-ventilated area away from heat sources, direct sunlight, and incompatible materials (strong acids, bases, oxidising agents). Maximum storage temperature 25°C. Maintain minimum 3-metre separation from ignition sources. Provide CO₂ or dry powder fire extinguishers rated minimum 13A 89B within 10 metres. Prohibit smoking and hot work within 10 metres of storage or application areas. Limit bulk applications; allow curing in thin layers to dissipate heat. Monitor temperature during large-scale applications. Ensure adequate ventilation during curing. Implement hot work permit system. Train personnel in fire emergency procedures.1 × 3 = 3
5. Exposure to hazardous decomposition products if adhesive subjected to elevated temperatures, welding, cutting, or grinding of bonded substrates
Harm: Inhalation of toxic isocyanate decomposition products including hydrogen cyanide, nitrogen oxides, carbon monoxide. Acute poisoning, respiratory distress, unconsciousness, potential fatality in severe exposures.
3 × 5 = 15Prohibit hot work (welding, cutting, grinding, flame work) on substrates bonded with PinkGrip unless adhesive fully removed and area decontaminated. Implement permit-to-work system for any hot work near cured adhesive. If hot work unavoidable, provide supplied-air respiratory protection (not filtered RPE). Install enhanced LEV with capture at source. Evacuate non-essential personnel from area. Conduct atmospheric monitoring for carbon monoxide, hydrogen cyanide, and nitrogen oxides. Provide emergency rescue equipment and trained rescue personnel. Brief all hot work contractors on hazards. Post warning signage. Ensure emergency procedures rehearsed.1 × 4 = 4

3. Step-by-Step Safe Sequence of Operations & Hold-Points

1

Pre-work COSHH assessment, area preparation, and ventilation verification

Preparation and Risk Assessment

Conduct site-specific COSHH assessment reviewing SDS and this assessment. Verify LEV system operational and tested within 14 months (check examination certificate). Measure capture velocity at point of application (≥0.5 m/s required). Confirm emergency eyewash station functional and within 10 seconds travel. Clear work area of ignition sources, incompatible materials, and non-essential personnel. Establish 3-metre exclusion zone with warning signage. Verify adequate lighting (≥500 lux). Check weather conditions if working outdoors (avoid rain, temperature <5°C or >25°C, high wind). Confirm all operatives hold valid training certificates for isocyanate work. Review emergency procedures with team. Obtain hot work permits if any welding/cutting planned nearby (minimum 10m separation). Inspect all PPE for damage and ensure correct sizes available.

Critical Hold-Point: STOP: Do not proceed if LEV system not operational, not tested within 14 months, or capture velocity inadequate. Respiratory sensitisation risk is IRREVERSIBLE. Do not proceed without valid face-fit test certificates for RPE users (maximum 3 years old). Confirm no operatives have pre-existing respiratory conditions or previous isocyanate sensitisation.
2

Don mandatory PPE and prepare dispensing equipment in controlled manner

PPE Donning and Equipment Setup

Wash hands thoroughly before donning PPE. Don disposable coveralls Type 5/6 ensuring full coverage and secure elasticated seals at wrists and ankles. Don nitrile gloves (≥0.4mm) ensuring cuffs overlap coverall sleeves by minimum 100mm. Inspect gloves for defects; replace if any damage visible. Don safety spectacles with side shields or full-face visor. If LEV inadequate or working in confined space, don face-fit tested half-mask respirator with A1P2 filters (check filter expiry dates and canister condition). Load 350ml PinkGrip cartridge into skeleton gun or pneumatic dispenser following manufacturer instructions. Point nozzle away from body and personnel during loading. Cut nozzle at 45° angle to required bead size (typically 6-10mm). Prime adhesive by dispensing small amount into waste container to purge air. Position LEV capture hood within 300mm of application point.

Critical Hold-Point: HOLD POINT: Verify glove integrity before handling cartridges. Single skin contact can cause permanent sensitisation. Ensure respirator seal check performed (positive and negative pressure checks per HSG53). Do not proceed if respirator fails seal check. Confirm filters are correct type (A1P2 minimum) and within service life.
3

Apply adhesive using controlled technique with continuous exposure monitoring

Application Phase

Position substrate securely to prevent movement during application. Apply adhesive in continuous beads or ribbons as per manufacturer's technical data sheet (typically 6-10mm diameter beads at 50mm centres for plasterboard, closer spacing for heavier materials). Maintain nozzle within LEV capture zone throughout application. Work systematically to minimise application time and exposure duration. Apply even pressure to dispenser trigger to control bead size and prevent splashing. For vertical applications, work from bottom upward to prevent drips. Immediately press and secure second substrate within open time (typically 10-20 minutes depending on temperature and humidity). Use temporary supports or props as required. Avoid excessive squeeze-out; wipe excess adhesive immediately with disposable cloth and dispose in sealed waste container. Take regular breaks (minimum 10 minutes every hour) in fresh air area to minimise cumulative exposure. Monitor for symptoms of respiratory irritation or skin contact.

Critical Hold-Point: CRITICAL: Maintain face and breathing zone minimum 500mm from application point at all times. If any respiratory symptoms develop (coughing, wheezing, chest tightness, breathing difficulty), STOP WORK IMMEDIATELY, move to fresh air, and seek medical attention. Report to supervisor. Do not re-enter work area. If skin contact occurs, remove contaminated gloves immediately, wash affected area with soap and water for minimum 15 minutes, and report to first aider.
4

Monitor curing process and maintain ventilation during polymerisation

Curing and Monitoring

Maintain ventilation (LEV and general) for minimum 24 hours after application or until adhesive fully cured (typically 24-48 hours depending on temperature, humidity, and bead thickness). Monitor work area temperature; if bulk application or confined space, check for heat generation during exothermic curing reaction. If temperature rise detected, increase ventilation and allow cooling. Restrict access to curing area with barrier tape and warning signage ('Isocyanate Adhesive Curing - Respiratory Hazard - Authorised Personnel Only - RPE Required'). Prohibit hot work within 10 metres until adhesive fully cured and area ventilated. If working in occupied building, ensure adequate separation or temporary relocation of sensitive individuals (asthmatics, pregnant workers, previously sensitised persons). Conduct air monitoring if concerns about vapour migration to adjacent areas. Record curing conditions (temperature, humidity, ventilation status) in site diary.

Critical Hold-Point: WARNING: Isocyanate vapours continue to be released during curing process. Maintain exclusion zone and ventilation. Do not allow unprotected personnel into area. In confined spaces or poorly ventilated areas, vapour concentrations may exceed WEL during curing. Conduct atmospheric monitoring before allowing unprotected entry.
5

Safely dispose of waste materials and decontaminate equipment and work area

Waste Disposal and Decontamination

Collect all waste materials (empty cartridges, contaminated wipes, excess adhesive, disposable PPE) in designated impervious waste container with sealed lid. Classify waste as hazardous waste (EWC code 08 04 09* - waste adhesives and sealants containing organic solvents or other dangerous substances) requiring disposal via licensed waste carrier with appropriate documentation. Do not dispose in general waste. Clean dispensing equipment nozzles and tools with appropriate cleaner while adhesive still wet (cured adhesive cannot be removed). Dispose of cleaning materials as hazardous waste. Wipe down work surfaces with damp cloth to capture any dust or residue. Dispose of cloth as hazardous waste. Do not dry sweep or use compressed air (risk of aerosol generation). Vacuum with HEXA-filtered vacuum if necessary. Decontaminate LEV capture hood and ductwork per maintenance schedule. Store partially used cartridges upright in sealed containers in designated storage area (cool, dry, away from heat).

Critical Hold-Point: STOP: Do not remove respirator until outside contaminated area and in fresh air. Remove gloves last using correct technique (peel from wrist turning inside-out to contain contamination). Dispose of gloves as hazardous waste. Do not reuse disposable PPE. Wash hands and face thoroughly with soap and water before eating, drinking, smoking, or using toilet facilities.
6

Complete documentation, health monitoring, and equipment inspection

Post-Work Review and Health Surveillance

Complete COSHH exposure record documenting: date, location, operatives involved, duration of exposure, adhesive quantity used, ventilation status, PPE worn, any incidents or symptoms. File record in health surveillance file (retain minimum 40 years per COSHH Regulation 11). Conduct post-work health check: ask each operative about respiratory symptoms (coughing, wheezing, breathlessness, chest tightness), skin symptoms (itching, redness, rash), or eye irritation. Record responses. If any symptoms reported, refer to occupational health provider immediately and complete accident/incident report. Inspect and test LEV system; record any defects or performance issues. Inspect RPE; clean and store per manufacturer instructions; replace filters if approaching service life. Review any near-misses or improvement opportunities with team. Update risk assessment if new hazards identified or controls found inadequate. Schedule next health surveillance appointment per programme (typically 6-12 months for isocyanate exposure).

Critical Hold-Point: MANDATORY: Any operative reporting respiratory symptoms must be immediately referred to occupational health physician for assessment. Do not allow return to isocyanate work until medically cleared. Respiratory sensitisation is permanent and progressive. Early detection critical. Maintain confidential health records per GDPR and retain for 40 years minimum.

Emergency Rescue, First Aid & Spill Protocol

EMERGENCY CONTACTS: Emergency Services 999, HSE Incident Contact Centre 0345 300 9923, National Poisons Information Service (medical professionals only) 0344 892 0111. INHALATION: Remove casualty immediately to fresh air away from contaminated area. Keep warm and at rest in semi-recumbent position. If breathing difficult, administer oxygen if trained and equipment available. If breathing stops, commence CPR if competent. Seek immediate medical attention. Inform medical personnel of isocyanate exposure and provide SDS. Monitor for delayed respiratory symptoms (occupational asthma may develop hours after exposure). SKIN CONTACT: Remove contaminated clothing immediately and isolate in sealed bag. Wash affected skin thoroughly with soap and lukewarm water for minimum 15 minutes. Do NOT use solvents, thinners, or abrasive cleaners on skin. Apply skin conditioning cream after washing. If irritation, rash, or sensitisation symptoms develop, seek medical attention. Provide SDS to medical personnel. Dispose of contaminated clothing as hazardous waste; do not launder. EYE CONTACT: Rinse immediately with clean water or eyewash solution for minimum 15 minutes, holding eyelids open. Remove contact lenses if present and easy to do. Continue rinsing. Seek immediate medical attention from ophthalmologist or A&E. Provide SDS. INGESTION (unlikely): Do NOT induce vomiting. Rinse mouth thoroughly with water. Give small amounts of water to drink if conscious. Seek immediate medical attention. Never give anything by mouth to unconscious person. FIRE: Evacuate area immediately. Alert fire brigade stating isocyanate-containing material involved. Use CO₂, dry powder, or foam extinguishers. Do NOT use water jet (may spread fire). Firefighters must wear full BA and chemical-resistant suits. Burning adhesive releases toxic gases including hydrogen cyanide, nitrogen oxides, and carbon monoxide. Establish exclusion zone downwind. SPILLAGE: Evacuate area and establish exclusion zone. Eliminate ignition sources. Wear full PPE including RPE. Ventilate area. Absorb liquid spills with inert absorbent material (sand, vermiculite). Collect in sealed containers for disposal as hazardous waste. Do not wash into drains or watercourses. Decontaminate area with suitable cleaner. Report significant spills to Environment Agency Incident Hotline 0800 807060. REPORTING: Report all exposures, symptoms, and incidents to supervisor immediately. Complete accident book entry. Report specified dangerous occurrences and occupational diseases to HSE per RIDDOR 2013 (occupational asthma from isocyanates is reportable). Investigate all incidents and implement corrective actions.

4. UK HSE Compliance FAQs: Everbuild Tecnic PinkGrip Solvent-Free Adhesive

5. Operative Toolbox Talk & Competent Person Sign-Off Register

Competent Person & Operative Declaration: By signing below, the Site Supervisor confirms this assessment has been adapted and verified for actual site conditions, and operatives confirm they have attended the pre-start Toolbox Talk for Everbuild Tecnic PinkGrip Solvent-Free Adhesive and will follow the safe system of work.

Operative / Supervisor Name Trade / Role & CSCS No. Signature Date & Time
1. (Site Supervisor):     
2.     
3.     
4.     
5.     
6.     

Related UK Safety Templates & Risk Assessments