Under COSHH 2002 (as amended), REACH, CLP Regulation, EH40 WELs, and HSG258 Controlling Airborne Contaminants at Work, employers must assess exposure to Everbuild Tecnic PinkGrip Solvent-Free Adhesive, implement engineering controls and local exhaust ventilation to prevent inhalation of vapours, ensure adequate skin protection against sensitisation, and reduce residual risk to tolerable levels through hierarchy of control measures. This COSHH assessment provides comprehensive hazard identification, exposure control strategies, mandatory PPE specifications, and emergency procedures for safe handling, application, and storage of this polymer-based construction adhesive. The product contains polymeric diphenylmethane diisocyanate (pMDI) which may cause respiratory sensitisation and skin irritation requiring strict exposure prevention. All operatives must receive competent instruction, training, and health surveillance where exposure cannot be adequately controlled. Workplace exposure limits must not be exceeded and air monitoring conducted where significant exposure risk exists.
| Identified Hazard & Harm | Initial Risk (L×S) | Mandatory Engineering, Isolation & Procedural Controls | Residual Risk |
|---|---|---|---|
| 1. Respiratory sensitisation from inhalation of pMDI vapours and aerosol mist during adhesive dispensing and application Harm: Occupational asthma, irreversible respiratory sensitisation, breathing difficulties, wheezing, chest tightness. Once sensitised, even trace exposures trigger severe reactions. Long-term lung damage and permanent disability possible. | 4 × 4 = 16 | Install and maintain LEV system per HSG258 with capture velocity ≥0.5 m/s at emission point. Conduct thorough examination and testing every 14 months by competent person. Implement health surveillance programme including pre-placement and periodic respiratory questionnaires and spirometry. Enforce mandatory RPE (A1P2 minimum) where LEV inadequate. Restrict access to trained, authorised personnel only. Monitor workplace air per HSG173 to verify exposure below WEL. Implement permit-to-work for confined space applications. Provide emergency respiratory support equipment. | 2 × 3 = 6 |
| 2. Skin sensitisation and allergic contact dermatitis from direct skin contact with uncured adhesive containing pMDI Harm: Allergic skin reactions, dermatitis, eczema, skin rashes, itching, blistering. Sensitisation is permanent; subsequent exposures cause increasingly severe reactions. May require job change if sensitised. | 4 × 3 = 12 | Enforce strict no-skin-contact policy. Mandatory nitrile gloves (≥0.4mm) per BS EN 374-1:2016 changed every 2 hours or immediately if contaminated. Provide barrier skin creams (pre-work) and after-work skin conditioning creams. Install washing facilities with warm water, mild soap, and disposable towels within immediate work area. Prohibit use of solvents for skin cleaning. Implement skin surveillance programme with regular inspections. Provide impervious coveralls Type 5/6. Train operatives in correct glove donning/doffing to prevent contamination. Isolate contaminated clothing immediately. | 2 × 2 = 4 |
| 3. Serious eye irritation from splashes, aerosol mist, or accidental contact during cartridge loading or application Harm: Serious eye irritation, pain, redness, watering, temporary vision impairment. Risk of corneal damage if not immediately irrigated. Potential for permanent eye damage with delayed treatment. | 3 × 3 = 9 | Mandatory safety spectacles with side shields (BS EN 166:2001 Class 1) or full-face visor for all personnel within 3 metres of application. Install emergency eyewash station per BS EN 15154-2:2006 within 10 seconds travel time. Train all operatives in emergency eyewash procedures. Implement safe systems of work for cartridge changing to minimise splash risk. Use low-pressure dispensing equipment to reduce aerosol generation. Prohibit overhead application without additional face protection. Ensure adequate lighting (minimum 500 lux) to prevent accidental contact. Supervise inexperienced operatives. | 2 × 2 = 4 |
| 4. Fire risk from storage of flammable cartridges and generation of heat during curing in bulk applications or confined spaces Harm: Fire, smoke inhalation, burns, property damage. Exothermic curing reaction in bulk can generate sufficient heat to ignite combustible materials. Smoke from burning adhesive releases toxic isocyanate decomposition products. | 2 × 4 = 8 | Store cartridges in cool, dry, well-ventilated area away from heat sources, direct sunlight, and incompatible materials (strong acids, bases, oxidising agents). Maximum storage temperature 25°C. Maintain minimum 3-metre separation from ignition sources. Provide CO₂ or dry powder fire extinguishers rated minimum 13A 89B within 10 metres. Prohibit smoking and hot work within 10 metres of storage or application areas. Limit bulk applications; allow curing in thin layers to dissipate heat. Monitor temperature during large-scale applications. Ensure adequate ventilation during curing. Implement hot work permit system. Train personnel in fire emergency procedures. | 1 × 3 = 3 |
| 5. Exposure to hazardous decomposition products if adhesive subjected to elevated temperatures, welding, cutting, or grinding of bonded substrates Harm: Inhalation of toxic isocyanate decomposition products including hydrogen cyanide, nitrogen oxides, carbon monoxide. Acute poisoning, respiratory distress, unconsciousness, potential fatality in severe exposures. | 3 × 5 = 15 | Prohibit hot work (welding, cutting, grinding, flame work) on substrates bonded with PinkGrip unless adhesive fully removed and area decontaminated. Implement permit-to-work system for any hot work near cured adhesive. If hot work unavoidable, provide supplied-air respiratory protection (not filtered RPE). Install enhanced LEV with capture at source. Evacuate non-essential personnel from area. Conduct atmospheric monitoring for carbon monoxide, hydrogen cyanide, and nitrogen oxides. Provide emergency rescue equipment and trained rescue personnel. Brief all hot work contractors on hazards. Post warning signage. Ensure emergency procedures rehearsed. | 1 × 4 = 4 |
Conduct site-specific COSHH assessment reviewing SDS and this assessment. Verify LEV system operational and tested within 14 months (check examination certificate). Measure capture velocity at point of application (≥0.5 m/s required). Confirm emergency eyewash station functional and within 10 seconds travel. Clear work area of ignition sources, incompatible materials, and non-essential personnel. Establish 3-metre exclusion zone with warning signage. Verify adequate lighting (≥500 lux). Check weather conditions if working outdoors (avoid rain, temperature <5°C or >25°C, high wind). Confirm all operatives hold valid training certificates for isocyanate work. Review emergency procedures with team. Obtain hot work permits if any welding/cutting planned nearby (minimum 10m separation). Inspect all PPE for damage and ensure correct sizes available.
Wash hands thoroughly before donning PPE. Don disposable coveralls Type 5/6 ensuring full coverage and secure elasticated seals at wrists and ankles. Don nitrile gloves (≥0.4mm) ensuring cuffs overlap coverall sleeves by minimum 100mm. Inspect gloves for defects; replace if any damage visible. Don safety spectacles with side shields or full-face visor. If LEV inadequate or working in confined space, don face-fit tested half-mask respirator with A1P2 filters (check filter expiry dates and canister condition). Load 350ml PinkGrip cartridge into skeleton gun or pneumatic dispenser following manufacturer instructions. Point nozzle away from body and personnel during loading. Cut nozzle at 45° angle to required bead size (typically 6-10mm). Prime adhesive by dispensing small amount into waste container to purge air. Position LEV capture hood within 300mm of application point.
Position substrate securely to prevent movement during application. Apply adhesive in continuous beads or ribbons as per manufacturer's technical data sheet (typically 6-10mm diameter beads at 50mm centres for plasterboard, closer spacing for heavier materials). Maintain nozzle within LEV capture zone throughout application. Work systematically to minimise application time and exposure duration. Apply even pressure to dispenser trigger to control bead size and prevent splashing. For vertical applications, work from bottom upward to prevent drips. Immediately press and secure second substrate within open time (typically 10-20 minutes depending on temperature and humidity). Use temporary supports or props as required. Avoid excessive squeeze-out; wipe excess adhesive immediately with disposable cloth and dispose in sealed waste container. Take regular breaks (minimum 10 minutes every hour) in fresh air area to minimise cumulative exposure. Monitor for symptoms of respiratory irritation or skin contact.
Maintain ventilation (LEV and general) for minimum 24 hours after application or until adhesive fully cured (typically 24-48 hours depending on temperature, humidity, and bead thickness). Monitor work area temperature; if bulk application or confined space, check for heat generation during exothermic curing reaction. If temperature rise detected, increase ventilation and allow cooling. Restrict access to curing area with barrier tape and warning signage ('Isocyanate Adhesive Curing - Respiratory Hazard - Authorised Personnel Only - RPE Required'). Prohibit hot work within 10 metres until adhesive fully cured and area ventilated. If working in occupied building, ensure adequate separation or temporary relocation of sensitive individuals (asthmatics, pregnant workers, previously sensitised persons). Conduct air monitoring if concerns about vapour migration to adjacent areas. Record curing conditions (temperature, humidity, ventilation status) in site diary.
Collect all waste materials (empty cartridges, contaminated wipes, excess adhesive, disposable PPE) in designated impervious waste container with sealed lid. Classify waste as hazardous waste (EWC code 08 04 09* - waste adhesives and sealants containing organic solvents or other dangerous substances) requiring disposal via licensed waste carrier with appropriate documentation. Do not dispose in general waste. Clean dispensing equipment nozzles and tools with appropriate cleaner while adhesive still wet (cured adhesive cannot be removed). Dispose of cleaning materials as hazardous waste. Wipe down work surfaces with damp cloth to capture any dust or residue. Dispose of cloth as hazardous waste. Do not dry sweep or use compressed air (risk of aerosol generation). Vacuum with HEXA-filtered vacuum if necessary. Decontaminate LEV capture hood and ductwork per maintenance schedule. Store partially used cartridges upright in sealed containers in designated storage area (cool, dry, away from heat).
Complete COSHH exposure record documenting: date, location, operatives involved, duration of exposure, adhesive quantity used, ventilation status, PPE worn, any incidents or symptoms. File record in health surveillance file (retain minimum 40 years per COSHH Regulation 11). Conduct post-work health check: ask each operative about respiratory symptoms (coughing, wheezing, breathlessness, chest tightness), skin symptoms (itching, redness, rash), or eye irritation. Record responses. If any symptoms reported, refer to occupational health provider immediately and complete accident/incident report. Inspect and test LEV system; record any defects or performance issues. Inspect RPE; clean and store per manufacturer instructions; replace filters if approaching service life. Review any near-misses or improvement opportunities with team. Update risk assessment if new hazards identified or controls found inadequate. Schedule next health surveillance appointment per programme (typically 6-12 months for isocyanate exposure).
EMERGENCY CONTACTS: Emergency Services 999, HSE Incident Contact Centre 0345 300 9923, National Poisons Information Service (medical professionals only) 0344 892 0111. INHALATION: Remove casualty immediately to fresh air away from contaminated area. Keep warm and at rest in semi-recumbent position. If breathing difficult, administer oxygen if trained and equipment available. If breathing stops, commence CPR if competent. Seek immediate medical attention. Inform medical personnel of isocyanate exposure and provide SDS. Monitor for delayed respiratory symptoms (occupational asthma may develop hours after exposure). SKIN CONTACT: Remove contaminated clothing immediately and isolate in sealed bag. Wash affected skin thoroughly with soap and lukewarm water for minimum 15 minutes. Do NOT use solvents, thinners, or abrasive cleaners on skin. Apply skin conditioning cream after washing. If irritation, rash, or sensitisation symptoms develop, seek medical attention. Provide SDS to medical personnel. Dispose of contaminated clothing as hazardous waste; do not launder. EYE CONTACT: Rinse immediately with clean water or eyewash solution for minimum 15 minutes, holding eyelids open. Remove contact lenses if present and easy to do. Continue rinsing. Seek immediate medical attention from ophthalmologist or A&E. Provide SDS. INGESTION (unlikely): Do NOT induce vomiting. Rinse mouth thoroughly with water. Give small amounts of water to drink if conscious. Seek immediate medical attention. Never give anything by mouth to unconscious person. FIRE: Evacuate area immediately. Alert fire brigade stating isocyanate-containing material involved. Use CO₂, dry powder, or foam extinguishers. Do NOT use water jet (may spread fire). Firefighters must wear full BA and chemical-resistant suits. Burning adhesive releases toxic gases including hydrogen cyanide, nitrogen oxides, and carbon monoxide. Establish exclusion zone downwind. SPILLAGE: Evacuate area and establish exclusion zone. Eliminate ignition sources. Wear full PPE including RPE. Ventilate area. Absorb liquid spills with inert absorbent material (sand, vermiculite). Collect in sealed containers for disposal as hazardous waste. Do not wash into drains or watercourses. Decontaminate area with suitable cleaner. Report significant spills to Environment Agency Incident Hotline 0800 807060. REPORTING: Report all exposures, symptoms, and incidents to supervisor immediately. Complete accident book entry. Report specified dangerous occurrences and occupational diseases to HSE per RIDDOR 2013 (occupational asthma from isocyanates is reportable). Investigate all incidents and implement corrective actions.
Competent Person & Operative Declaration: By signing below, the Site Supervisor confirms this assessment has been adapted and verified for actual site conditions, and operatives confirm they have attended the pre-start Toolbox Talk for Everbuild Tecnic PinkGrip Solvent-Free Adhesive and will follow the safe system of work.
| Operative / Supervisor Name | Trade / Role & CSCS No. | Signature | Date & Time |
|---|---|---|---|
| 1. (Site Supervisor): | |||
| 2. | |||
| 3. | |||
| 4. | |||
| 5. | |||
| 6. |