SafeSequence › UK Safety Template Library › Commercial Brand COSHH › C-Tec CT1 Hybrid Polymer Construction Sealant & Multisolve Solvent
Reference UK COSHH Example • Commercial Brand COSHH

C-Tec CT1 Hybrid Polymer Construction Sealant & Multisolve Solvent (COSHH Template & 5x5 Risk Assessment)

Under COSHH Regulations 2002, EH40/2005 Workplace Exposure Limits, and UK CLP Regulation, employers must assess and control exposure to C-Tec CT1 hybrid polymer sealant and Multisolve solvent through hierarchy of controls including engineering ventilation, isolation of work areas, and mandatory respiratory protection where vapour concentrations may exceed 8-hour TWA limits. Target risk reduction from high (15-20) to low (3-6) through elimination of skin contact, LEV systems, and strict permit-to-work protocols for confined space applications.

Statutory FrameworkCOSHH Regulations 2002, EH40/2005 Workplace Exposure Limits, UK CLP Regulation
ClassificationC-Tec CT1 Sealant: Not classified as hazardous under UK CLP but contains polymer resins requiring skin sensitisation precautions. Multisolve Solvent: GHS02 Flammable Liquid Category 3 (H226), GHS07 Harmful if inhaled (H332), Skin Irritant Category 2 (H315), Eye Irritant Category 2 (H319). Contains d-Limonene (CAS 5989-27-5) and aliphatic hydrocarbons. Flash point: 55°C. Store below 25°C in original containers away from ignition sources. Dispose via licensed hazardous waste contractor (EWC code 14 06 03*).
Required Plant / KitLocal Exhaust Ventilation (LEV) system with minimum 0.5 m/s capture velocity tested to HSG258 standards • Explosion-proof electrical equipment rated ATEX Zone 2 for Multisolve handling areas • Sealed chemical storage cabinet with spill containment sump (110% capacity) and mechanical ventilation • Calibrated gas detection monitor for hydrocarbon vapours (0-500 ppm range) with audible alarm • Emergency eyewash station compliant with BS EN 15154-2:2006 within 10 metres of application area
Site Sign-Off StatusRequires Competent Person Verification
Instant AI Customization or Free Blank Word (.doc) Download

Need this COSHH customized with your Company Name, Site Postcode & Nearest A&E Hospital?

Dictate your site specifics on your phone in 45 seconds to auto-compile a signed PDF—or download our free blank Word (.doc) shell below.

Auto-Fill via Voice / CLP (45s)

1. Mandatory Personal Protective Equipment (BS EN Standards)

BS EN 374-1:2016 Type B, BS EN ISO 374-5:2016 (VIRUS)
Nitrile chemical-resistant gloves (minimum 0.4mm thickness)
Prevent dermal absorption of d-Limonene and polymer resins causing skin sensitisation and irritant contact dermatitis per COSHH ACoP L5
BS EN 166:2001 (Optical Class 1, Marking: 2C-1.2 1 F)
Safety spectacles with side shields or full-face visor
Protect against liquid splash and vapour irritation to eyes from Multisolve solvent (H319 Eye Irritant Category 2)
BS EN 140:1999 with A1 or A2 filters to BS EN 14387:2004+A1:2008
Organic vapour respirator (half-mask or full-face)
Mandatory where LEV inadequate or in confined spaces to prevent inhalation exposure exceeding d-Limonene WEL (150 ppm 8-hr TWA per EH40/2005)
BS EN ISO 20345:2011 S3 SRC (Steel toecap, penetration-resistant midsole)
Chemical-resistant safety footwear with anti-slip sole
Prevent foot contamination from spills and provide slip resistance on solvent-contaminated surfaces

2. 5×5 Hazard Risk Assessment Matrix (HASAWA 1974 / MHSWR 1999)

Identified Hazard & HarmInitial Risk (L×S)Mandatory Engineering, Isolation & Procedural ControlsResidual Risk
1. Inhalation of organic vapours (d-Limonene, aliphatic hydrocarbons) from Multisolve solvent during application in poorly ventilated areas
Harm: Acute: Dizziness, headache, nausea, respiratory irritation. Chronic: Central nervous system depression, potential liver/kidney damage with prolonged exposure above WEL
4 × 4 = 16Install and maintain LEV system to HSG258 with thorough examination every 14 months. Conduct air monitoring per MDHS 96 to verify d-Limonene below 150 ppm 8-hr TWA (EH40/2005). Implement permit-to-work for confined spaces with forced ventilation and continuous gas monitoring. Provide A1/A2 organic vapour respirators where engineering controls insufficient. Rotate workers to limit exposure duration. Health surveillance per COSHH Regulation 11 for respiratory symptoms.2 × 2 = 4
2. Skin contact with CT1 polymer resins and Multisolve causing sensitisation and irritant dermatitis
Harm: Allergic contact dermatitis, skin irritation (erythema, cracking), potential Type IV hypersensitivity requiring permanent product avoidance
5 × 3 = 15Enforce strict no-touch policy with mandatory nitrile gloves (BS EN 374-1:2016 Type B, minimum 0.4mm). Provide barrier creams (pre-work) and emollient creams (post-work) per HSG224. Install wash stations with pH-neutral soap within 5 metres. Implement skin surveillance programme with photographic records. Replace gloves every 2 hours or immediately if contaminated. Prohibit eating/drinking/smoking in work areas. Provide disposable coveralls (Type 5/6) for extensive application work.3 × 2 = 6
3. Fire and explosion risk from flammable Multisolve solvent (Flash point 55°C, GHS02 H226)
Harm: Thermal burns, smoke inhalation, explosion injuries, property damage, potential fatalities in confined spaces
3 × 5 = 15Store Multisolve in ATEX-compliant flammable storage cabinet with mechanical ventilation and spill sump. Eliminate ignition sources within 5-metre radius (hot work permit required). Use ATEX Zone 2 rated electrical equipment and intrinsically safe tools. Maintain ambient temperature below 25°C. Limit quantities to single-shift requirements (<5 litres in work area). Provide CO2 or foam fire extinguishers (Class B) within 10 metres. Bond and earth containers during decanting. Prohibit smoking and naked flames. Emergency isolation of electrical supplies via clearly marked isolators.2 × 3 = 6
4. Eye exposure to Multisolve liquid splash or vapour causing irritation (H319)
Harm: Conjunctivitis, corneal damage, temporary vision impairment, potential permanent eye injury if not irrigated immediately
4 × 3 = 12Mandatory safety spectacles with side shields (BS EN 166:2001 Optical Class 1) for all personnel within 3 metres of application. Install BS EN 15154-2:2006 compliant eyewash station within 10 metres with weekly flow testing. For overhead work or spray application, upgrade to full-face visor or sealed goggles (BS EN 166 Marking 3). Train operatives in 15-minute continuous irrigation protocol. Maintain emergency eyewash log. Prohibit contact lens wear during solvent handling.2 × 2 = 4
5. Confined space working with inadequate ventilation leading to oxygen depletion and vapour accumulation
Harm: Asphyxiation, loss of consciousness, acute solvent toxicity, potential fatality within minutes in oxygen-deficient atmosphere
2 × 5 = 10Implement Confined Spaces Regulations 1997 permit-to-work system. Conduct pre-entry atmospheric testing for oxygen (>19.5%), flammable vapours (<10% LEL), and toxic gases using calibrated multi-gas detector. Provide continuous forced ventilation (minimum 6 air changes/hour) with ducted fresh air supply. Station trained attendant outside with rescue equipment and communication system. Use airline breathing apparatus (BS EN 14593-1:2005) rather than filtering respirators. Establish emergency rescue plan with fire service notification. Prohibit lone working. Implement lockout/tagout (LOTO) on all services entering confined space.1 × 4 = 4

3. Step-by-Step Safe Sequence of Operations & Hold-Points

1

COSHH Assessment Review and Permit Authorisation

Pre-Work Preparation

Review site-specific COSHH assessment with all operatives. Verify LEV system thorough examination certificate is current (within 14 months per HSG258). Complete permit-to-work if working in confined space, near ignition sources, or where hot work conducted within 10 metres in previous 60 minutes. Confirm emergency eyewash station tested within 7 days. Check Multisolve storage temperature (<25°C) and container integrity. Verify all operatives hold valid health surveillance certificates for solvent exposure. Establish exclusion zone (3-metre radius) with warning signage.

Critical Hold-Point: STOP: Do not proceed if LEV system examination certificate expired, confined space permit incomplete, or organic vapour respirators unavailable. Verify fire extinguishers (Class B CO2/foam) within 10 metres and emergency exits unobstructed.
2

Ventilation Setup and Ignition Source Elimination

Area Preparation and Isolation

Activate LEV system and verify capture velocity ≥0.5 m/s at source using anemometer. For confined spaces, establish forced ventilation with ducted fresh air (minimum 6 air changes/hour) and conduct atmospheric testing (O₂ >19.5%, hydrocarbons <10% LEL). Eliminate all ignition sources within 5-metre radius: isolate electrical equipment via lockout/tagout (LOTO), remove hot surfaces, prohibit smoking/naked flames. Deploy continuous gas monitoring with alarm set at 25% d-Limonene WEL (37.5 ppm). Establish decontamination zone with wash station and waste container.

Critical Hold-Point: HOLD POINT: Confined space entry prohibited until atmospheric test confirms oxygen ≥19.5% and hydrocarbon vapours <10% LEL. Trained attendant must be stationed outside with rescue equipment and communication system operational.
3

Personal Protective Equipment Fit and Integrity Verification

PPE Donning and Pre-Application Checks

Don nitrile chemical-resistant gloves (BS EN 374-1:2016 Type B, minimum 0.4mm thickness) and inspect for tears or degradation. Fit organic vapour respirator (BS EN 140:1999 with A1/A2 filters) and conduct positive/negative pressure seal check per manufacturer instructions. Wear safety spectacles with side shields (BS EN 166:2001) or full-face visor for overhead work. Apply barrier cream to exposed skin. Don chemical-resistant coveralls (Type 5/6) if extensive application anticipated. Verify emergency communication device functional. Confirm spill kit location and contents (absorbent pads, disposal bags, neutralising agent).

Critical Hold-Point: MANDATORY: Respirator fit-testing must be current (within 3 years per HSG53). If facial hair prevents seal, use powered air-purifying respirator (PAPR) or airline breathing apparatus. Replace gloves every 2 hours or immediately if contaminated.
4

Controlled Handling of CT1 Sealant and Multisolve Solvent

Product Dispensing and Application

Decant only required quantity of Multisolve into bonded/earthed secondary container to prevent static discharge. Apply CT1 sealant using manual applicator gun or pneumatic dispenser with LEV capture hood positioned within 300mm of work point. Use Multisolve sparingly on lint-free cloth for surface preparation or tool cleaning—never spray or pour directly onto surfaces. Work in well-ventilated areas with continuous air monitoring. Avoid skin contact; if contamination occurs, immediately remove gloves and wash with pH-neutral soap and water (do not use Multisolve on skin). Seal containers immediately after use. Rotate operatives every 2 hours to limit exposure duration.

Critical Hold-Point: STOP: If gas monitor alarms (>37.5 ppm hydrocarbons) or respiratory irritation occurs, evacuate area immediately and increase ventilation. Do not re-enter until vapour levels below 25% WEL and symptoms resolved. Report incident to supervisor and occupational health.
5

Contaminated Equipment Decontamination and Disposal

Tool Cleaning and Waste Management

Clean tools and applicators using minimal Multisolve on disposable cloths within designated decontamination zone under LEV extraction. Place all contaminated materials (cloths, gloves, cartridges, empty containers) into sealed hazardous waste container labelled with EWC code 14 06 03* (solvent waste). Do not mix with general waste. Seal partially used Multisolve containers and return to flammable storage cabinet. Wipe down work surfaces with detergent solution. Inspect PPE for contamination; dispose of single-use items and decontaminate reusable equipment per manufacturer instructions. Wash hands and forearms thoroughly with pH-neutral soap before eating, drinking, or smoking.

Critical Hold-Point: PROHIBITION: Never dispose of Multisolve or contaminated materials down drains or in general waste. Flammable vapours can accumulate in drainage systems causing explosion risk. Arrange collection by licensed hazardous waste contractor with consignment note documentation.
6

Exposure Assessment and Health Surveillance Recording

Post-Work Monitoring and Documentation

Deactivate LEV system only after confirming vapour levels below detection limits on gas monitor. Complete COSHH exposure record documenting: products used, quantities, duration, PPE worn, LEV operation, and any incidents/near-misses. Report any adverse health effects (skin irritation, respiratory symptoms, headache) to occupational health within 24 hours. Update health surveillance records per COSHH Regulation 11. Conduct post-work skin inspection for dermatitis signs. Schedule next LEV thorough examination if due within 2 months. File permit-to-work and atmospheric test results. Review control effectiveness and update risk assessment if exposures exceeded or controls failed.

Critical Hold-Point: MANDATORY REPORTING: Any skin sensitisation, respiratory symptoms persisting >4 hours, or loss of consciousness must be reported under RIDDOR 2013 as dangerous occurrence or occupational disease. Initiate immediate medical referral and incident investigation.

Emergency Rescue, First Aid & Spill Protocol

**INHALATION:** Remove casualty to fresh air immediately. If breathing difficult, administer oxygen if trained and available. If breathing stops, commence CPR and call 999. Position in recovery position if unconscious but breathing. Seek immediate medical attention for all cases of significant vapour inhalation. **SKIN CONTACT:** Remove contaminated clothing immediately. Wash affected area with copious amounts of water and pH-neutral soap for minimum 15 minutes. Do NOT use solvents or abrasives on skin. Apply emollient cream. Seek medical advice if irritation, redness, or sensitisation develops. **EYE CONTACT:** Irrigate eyes immediately with eyewash station or clean water for minimum 15 minutes, holding eyelids open. Remove contact lenses if present and easy to do. Continue irrigation. Seek immediate medical attention—transport to A&E with product Safety Data Sheet. **INGESTION:** Do NOT induce vomiting due to aspiration risk. Rinse mouth with water. Give small amounts of water to drink if conscious. Seek immediate medical attention. Never give anything by mouth to unconscious person. **FIRE:** Evacuate area and call 999. Use CO2, foam, or dry powder extinguishers (Class B)—never use water jet which may spread fire. Wear breathing apparatus if smoke inhalation risk. Cool containers with water spray from safe distance. **SPILLAGE:** Evacuate area and eliminate ignition sources. Ventilate thoroughly. Wear full PPE including respirator. Absorb with vermiculite, sand, or proprietary absorbent. Place in sealed container labelled as hazardous waste (EWC 14 06 03*). Wash residue with detergent solution. Report spills >5 litres to Environment Agency Incident Hotline: 0800 807060.

4. UK HSE Compliance FAQs: C-Tec CT1 Hybrid Polymer Construction Sealant & Multisolve Solvent

Do we actually need respiratory protection for CT1 and Multisolve if we've got the workshop doors open, or is that overkill for small jobs?

Natural ventilation via open doors is insufficient to control vapour exposure to d-Limonene below the EH40/2005 WEL of 150 ppm 8-hour TWA, particularly in confined or semi-enclosed spaces. COSHH Regulation 7 requires adequate control, which for volatile solvents means LEV systems tested to HSG258 or, where LEV is impracticable, organic vapour respirators (BS EN 140:1999 with A1/A2 filters). Air monitoring per MDHS 96 is the only way to verify exposure levels—without data, you must assume respiratory protection is mandatory. Small job duration does not eliminate the requirement; short-term exposure limits (STEL) still apply. Enforcement notices and prosecution under Section 33 HSWA 1974 have resulted from inadequate solvent vapour control even for brief tasks.

How often do we need to get the extraction system tested when we're using Multisolve regularly, and who's qualified to do the LEV examination?

Under COSHH Regulation 9 and HSG258 guidance, LEV systems controlling solvent vapours must undergo thorough examination and test by a competent person at least every 14 months, with the examination certificate retained for 5 years. 'Competent person' means someone with sufficient training, experience, and knowledge—typically holding BOHS P601 (LEV) qualification or equivalent. Between statutory examinations, you must conduct weekly visual checks (ductwork integrity, fan operation, filter condition) and monthly performance tests using smoke tubes or anemometer to verify capture velocity ≥0.5 m/s at source. If the system shows reduced performance (poor capture, visible vapour escape), conduct immediate re-examination rather than waiting for the 14-month interval. Failure to maintain examination records is a common HSE enforcement finding.

If someone gets CT1 or Multisolve on their skin and washes it off straight away, do we still need to record it in the accident book or report it anywhere?

Yes—all skin contact with substances capable of causing sensitisation or irritation must be recorded in your COSHH exposure records and accident book, even if immediately decontaminated. This creates an audit trail for health surveillance under COSHH Regulation 11, as allergic contact dermatitis can develop after repeated low-level exposures (Type IV hypersensitivity). If the person develops dermatitis symptoms (redness, itching, cracking) within 7 days, refer to occupational health immediately. If dermatitis results in absence from work for >7 consecutive days or prevents normal duties, it becomes reportable under RIDDOR 2013 as an occupational disease. Additionally, patterns of skin contact incidents indicate control failure requiring risk assessment review per COSHH Regulation 6(3). HSE inspectors specifically examine skin exposure records during COSHH audits—absence of documentation suggests inadequate monitoring and can trigger improvement notices.

5. Operative Toolbox Talk & Competent Person Sign-Off Register

Competent Person & Operative Declaration: By signing below, the Site Supervisor confirms this assessment has been adapted and verified for actual site conditions, and operatives confirm they have attended the pre-start Toolbox Talk for C-Tec CT1 Hybrid Polymer Construction Sealant & Multisolve Solvent and will follow the safe system of work.

Operative / Supervisor Name Trade / Role & CSCS No. Signature Date & Time
1. (Site Supervisor):     
2.     
3.     
4.     
5.     
6.     

Related UK Safety Templates & Risk Assessments