Under COSHH 2002 Regulation 7, HSE MWF Guidance INDG365, and EH40/2005 Workplace Exposure Limits, employers must prevent or adequately control exposure to Castrol Hysol and Almaredge semi-synthetic soluble CNC cutting fluids through engineering controls, local exhaust ventilation, sump monitoring for bacteria (≤10³ CFU/ml) and endotoxin (≤90 EU/ml), and mist suppression to reduce dermal sensitisation, respiratory harm, and microbial contamination risks to tolerable levels. This COSHH assessment provides a structured hierarchy of controls including fluid concentration management (5-10% typical dilution), machine guarding, extraction systems, and health surveillance protocols. Regular fluid testing, pH monitoring (9.0-9.5 optimal), and biocide dosing schedules are mandatory to maintain fluid integrity and worker protection. Competent persons must conduct exposure assessments, implement safe systems of work, and ensure compliance with the Control of Substances Hazardous to Health Regulations throughout the fluid lifecycle from mixing to disposal.
| Identified Hazard & Harm | Initial Risk (L×S) | Mandatory Engineering, Isolation & Procedural Controls | Residual Risk |
|---|---|---|---|
| 1. Dermal sensitisation and allergic contact dermatitis from biocides (formaldehyde releasers, isothiazolinones) and additives in concentrate and diluted fluid Harm: Skin Sens. 1 (H317): Allergic skin reactions, irritant contact dermatitis, folliculitis (oil acne), chronic hand eczema requiring medical treatment and potential ill-health retirement. Repeated exposure increases sensitisation risk. | 4 × 3 = 12 | Engineering: Automated fluid mixing and dosing systems to eliminate manual handling of concentrate. Enclosed CNC machine sumps with effective mist extraction (LEV to HSG258 standard, capture velocity ≥1 m/s at source). Administrative: Mandatory use of nitrile gloves (BS EN ISO 374-1 Type B) during all fluid contact tasks. Pre-employment and periodic health surveillance (skin checks) per HSE guidance. Skin inspection training for supervisors. Provision of pH-neutral, fragrance-free skin cleansers and moisturisers (COSHH Essentials MIST1). Rotate tasks to limit exposure duration. Immediate washing facilities available. SDS review and toolbox talks on sensitisation risks. | 3 × 2 = 6 |
| 2. Inhalation of metalworking fluid mist and aerosols containing bacteria, endotoxins, and chemical additives during CNC machining operations Harm: Respiratory sensitisation, occupational asthma, extrinsic allergic alveolitis (hypersensitivity pneumonitis), chronic bronchitis, and reduced lung function. Endotoxin exposure causes acute flu-like symptoms (Monday morning fever). EH40/2005 WEL exceedance (5 mg/m³ 8-hr TWA oil mist). | 4 × 4 = 16 | Engineering: Local exhaust ventilation (LEV) systems designed to HSG258 with minimum 20 air changes/hour in machining area. On-machine mist extractors with HEPA filtration (H13 minimum per BS EN 1822). Enclose high-speed machining operations with interlocked guards. Maintain fluid concentration within manufacturer's specification (5-10%) using refractometer checks (weekly minimum). Implement HSE INDG365 monitoring: bacteria ≤10³ CFU/ml, endotoxin ≤90 EU/ml. Biocide dosing schedule per SDS. Administrative: LEV thorough examination and test (TExT) every 14 months per COSHH Regulation 9. Air monitoring for oil mist (personal sampling) annually or when process changes. Respiratory health surveillance (questionnaire, spirometry) for exposed workers. Fluid replacement when bacteria/endotoxin limits exceeded. | 2 × 3 = 6 |
| 3. Microbial contamination of sump fluid (bacteria, fungi, endotoxins) due to inadequate maintenance, tramp oil ingress, or low biocide levels Harm: Exposure to Gram-negative bacteria (Pseudomonas, Mycobacterium) and endotoxins causing respiratory illness, skin infections, allergic alveolitis, and unpleasant odours. Non-compliance with HSE INDG365 bacteria limit (10³ CFU/ml) and endotoxin limit (90 EU/ml). | 5 × 3 = 15 | Engineering: Install tramp oil skimmers and coalescers to remove hydraulic/lubricating oil contamination (target <2% tramp oil). Maintain sump pH 9.0-9.5 using pH meter (daily checks). Automated biocide dosing systems with interlock to prevent under-dosing. Sump cleaning schedule (minimum quarterly or when bacteria limits exceeded). Administrative: Weekly dip-slide bacteria testing per HSE INDG365. Monthly laboratory endotoxin analysis (LAL test). Fluid concentration checks using refractometer (daily or per shift). Documented fluid management plan including top-up, biocide addition, and disposal criteria. Competent person (trained in MWF management) responsible for monitoring. Replace fluid when bacteria >10⁴ CFU/ml or endotoxin >90 EU/ml despite biocide treatment. Prevent coolant stagnation over weekends/shutdowns by circulation or biocide boost. | 2 × 2 = 4 |
| 4. Eye contact with alkaline concentrate (pH 9.5-10.5) or splash from diluted fluid during mixing, filling, or maintenance causing serious eye irritation (H319) Harm: Immediate pain, redness, lacrimation, corneal damage, and potential long-term vision impairment if not irrigated promptly. Alkaline burns more severe than acidic due to saponification of eye tissues. | 3 × 4 = 12 | Engineering: Closed fluid transfer systems with quick-disconnect couplings to eliminate splash during concentrate dispensing. Automated mixing stations with enclosed fill points. Eyewash stations (BS EN 15154-2:2006 compliant) located within 10 seconds travel time of all fluid handling areas. Administrative: Mandatory use of chemical goggles (BS EN 166:2001, 1 B 3 marking) during concentrate handling, mixing, and sump maintenance. Emergency eyewash procedure displayed at all stations (irrigate for minimum 15 minutes, seek medical attention). Toolbox talks on eye protection and emergency response. Supervisor spot-checks for PPE compliance. Pre-task risk assessment for non-routine maintenance (e.g. sump cleaning, filter changes). | 2 × 2 = 4 |
| 5. Slips, trips, and falls on fluid-contaminated floors around CNC machines, mixing areas, and sump maintenance zones Harm: Fractures, sprains, lacerations, head injuries, and potential long-term disability. Cutting fluid creates extremely slippery surfaces, particularly on smooth concrete or painted floors. Secondary risk of contact with contaminated fluid during fall. | 5 × 3 = 15 | Engineering: Install slip-resistant flooring (minimum R11 rating per DIN 51130) in machining and fluid handling areas. Provide drip trays and bunds under all machines and fluid containers. Automated fluid delivery systems to minimise manual handling and spillage. Floor drainage with oil/water separators. Administrative: Immediate spill cleanup procedure with absorbent materials (granules, pads) available at all workstations. Daily housekeeping inspections and documented cleaning schedules. 'Wet Floor' signage during and after cleaning. Non-slip safety footwear (BS EN ISO 20345 S2/S3 with SRC slip resistance) mandatory. Segregate pedestrian and fluid transfer routes. Training on manual handling and spill response. Adequate lighting (minimum 500 lux in machining areas per HSE guidance). | 2 × 2 = 4 |
Obtain current Safety Data Sheet (SDS) for specific Castrol Hysol or Almaredge product variant from supplier. Competent person (COSHH assessor) must review SDS Section 8 (exposure controls) and Section 11 (toxicological information) to identify hazards and required controls. Verify local exhaust ventilation (LEV) system is operational and within test date (TExT certificate valid, maximum 14 months old per COSHH Regulation 9). Confirm eyewash stations are functional (weekly flush test documented). Check availability of required PPE (nitrile gloves, goggles, coveralls) in correct sizes. Ensure refractometer, pH meter, and dip-slide test kits are available and in calibration. Review fluid management plan including target concentration (typically 5-10% for semi-synthetic), biocide dosing schedule, and monitoring frequency (weekly bacteria, monthly endotoxin per HSE INDG365). Confirm workers have received COSHH training and health surveillance is current.
Don full PPE: nitrile gloves (BS EN ISO 374-1), chemical goggles (BS EN 166), and fluid-resistant coveralls. Use dedicated mixing area with LEV extraction active. ALWAYS ADD CONCENTRATE TO WATER, never reverse (prevents emulsion instability and heat generation). Use clean, soft water (hardness <200 ppm CaCO₃ equivalent; consult SDS for specific requirements). Measure concentrate using calibrated dispensing equipment or pump. For 5% solution: add 5 litres concentrate to 95 litres water. Mix thoroughly using mechanical stirrer or recirculation pump (minimum 15 minutes) to ensure stable emulsion. Measure concentration using refractometer (target Brix reading per SDS conversion chart, typically 2-4° Brix for 5% solution). Measure pH using calibrated meter (target 9.0-9.5). Adjust concentration or add biocide per manufacturer's instructions if pH is outside range. Record batch details: date, concentration, pH, Brix reading, and operator name in fluid management log.
DAILY: Check fluid concentration using refractometer at start of shift (record in log). Measure pH using calibrated meter (target 9.0-9.5). Visually inspect for tramp oil (surface film), unusual odour (indicates bacterial growth), or discolouration. Top up with freshly mixed fluid to maintain level and concentration. Remove visible tramp oil using skimmer or absorbent pads. WEEKLY: Conduct bacteria and fungi enumeration using dip-slide test per HSE INDG365 (target ≤10³ CFU/ml for bacteria). Incubate dip-slide per manufacturer's instructions (typically 48 hours at 30°C) and compare to reference chart. If bacteria >10³ CFU/ml, increase biocide dose per SDS and retest after 48 hours. MONTHLY: Send sump sample to accredited laboratory for endotoxin analysis using LAL test (target ≤90 EU/ml per HSE INDG365). Check LEV system performance (visual inspection of airflow, filter condition). QUARTERLY: Full sump clean-out and fluid replacement (or sooner if bacteria >10⁴ CFU/ml or endotoxin >90 EU/ml despite treatment).
Ensure CNC machine guards and doors are closed during operation (interlocked where possible) to contain mist. Verify on-machine mist extractor is running and filters are not blocked (check pressure drop indicator if fitted). Maintain fluid concentration within specification (5-10%) to optimise cooling and minimise mist generation—low concentration increases mist, high concentration increases dermal exposure risk. Avoid directing high-pressure coolant jets at operators or open areas. Use flood coolant or through-tool delivery where possible to reduce aerosol generation. Workers must wear nitrile gloves when handling workpieces, loading/unloading machines, or any contact with fluid. Change gloves when visibly contaminated or damaged. Wash hands with pH-neutral cleanser and apply moisturiser before breaks and end of shift (do not use solvents or abrasive soaps). Report any skin irritation, rash, or respiratory symptoms to supervisor immediately for health surveillance review.
Before maintenance: Isolate machine electrically (LOTO per company procedure), allow fluid to cool (<40°C), and ensure LEV remains operational. Don full PPE including nitrile gloves, goggles, and fluid-resistant coveralls. Drain sump fluid into designated waste container (do not discharge to drain—waste cutting fluid is hazardous waste requiring licensed disposal per Environmental Protection Act 1990). Remove and dispose of swarf and sludge as contaminated waste. Clean sump using low-pressure water and pH-neutral detergent (avoid high-pressure jetting which generates aerosol). Inspect sump for corrosion, seal damage, or tramp oil ingress points. Replace filters, seals, and worn components. Disinfect sump using biocide solution per manufacturer's instructions (contact time typically 30 minutes). Rinse thoroughly and refill with freshly mixed fluid per Step 2. Test concentration, pH, and bacteria before returning to service. Dispose of contaminated PPE and cleaning materials as hazardous waste.
Waste cutting fluid is classified as hazardous waste under List of Wastes (England) Regulations 2005 (EWC code 13 01 13* or 13 02 08* depending on chlorine content—consult SDS). Segregate waste fluid from other waste streams and store in sealed, labelled containers in bunded area. Arrange collection by licensed waste carrier (check Environment Agency registration). Complete hazardous waste consignment notes per Hazardous Waste Regulations 2005. Do not mix with other chemicals or discharge to foul or surface water drains (offence under Environmental Permitting Regulations 2016). Empty concentrate containers may retain hazardous residues—triple rinse and dispose as hazardous waste or return to supplier for recycling. Contaminated PPE (gloves, coveralls), absorbent materials, and dip-slides must be disposed as hazardous waste. Maintain waste transfer documentation for minimum 3 years. Report any spills or environmental releases to Environment Agency Incident Hotline (0800 807060) and site management immediately.
Competent Person & Operative Declaration: By signing below, the Site Supervisor confirms this assessment has been adapted and verified for actual site conditions, and operatives confirm they have attended the pre-start Toolbox Talk for Castrol Hysol & Almaredge Semi-Synthetic Soluble CNC Cutting Fluid and will follow the safe system of work.
| Operative / Supervisor Name | Trade / Role & CSCS No. | Signature | Date & Time |
|---|---|---|---|
| 1. (Site Supervisor): | |||
| 2. | |||
| 3. | |||
| 4. | |||
| 5. | |||
| 6. |