Under COSHH Regulations 2002 (as amended) and Environment Agency PPG2 Bunded Storage Guidelines, commercial AdBlue (ISO 22241 AUS 32 aqueous urea solution, 32.5% urea in demineralised water) bulk storage and dispensing operations require secondary containment (110% capacity bunding), segregation from incompatible substances, and controlled dispensing procedures to prevent environmental contamination and minimise dermal/ocular exposure, achieving residual risk ≤8 (Low) through engineering controls and PPE.

Statutory FrameworkCOSHH Regulations 2002, Environment Agency PPG2 Bunded Storage Guidelines
ClassificationAdBlue (AUS 32) is not classified as dangerous under CLP Regulation (EC) No 1272/2008. ISO 22241 standard specifies 32.5% urea (CAS 57-13-6) in demineralised water. GHS Classification: Not classified as hazardous. However, prolonged skin contact may cause mild irritation. Product is alkaline (pH 9.0-9.5). Not subject to UN transport classification. Store between -11°C and +30°C to prevent crystallisation or decomposition. Incompatible with strong oxidisers, acids, and metals (copper, brass, aluminium). Shelf life 12 months in sealed containers, 6 months in opened/dispensing systems.
Required Plant / KitBunded AdBlue storage tank (minimum 110% secondary containment capacity, MDPE/stainless steel 316 construction) • Calibrated AdBlue dispensing pump with automatic shut-off and drip tray (ISO 22241 compliant materials) • Spill containment kit (minimum 50L absorbent granules, disposal bags, warning signs) • Tank level monitoring system with overfill alarm and visual/audible warning • Dedicated AdBlue transfer hoses (ISO 22241 compliant, clearly labelled, stored off ground on designated rack)
Site Sign-Off StatusRequires Competent Person Verification
Instant AI Customization or Free Blank Word (.doc) Download

Need this COSHH customized with your Company Name, Site Postcode & Nearest A&E Hospital?

Dictate your site specifics on your phone in 45 seconds to auto-compile a signed PDF—or download our free blank Word (.doc) shell below.

Auto-Fill via Voice / CLP (45s)

1. Mandatory Personal Protective Equipment (BS EN Standards)

BS EN ISO 374-1:2016 Type B (minimum 30-minute permeation)
Chemical-resistant gloves (nitrile or neoprene)
Prevent dermal contact with aqueous urea solution causing skin irritation and drying during dispensing and spill response
BS EN 166:2001 (minimum Grade 3 liquid droplet protection)
Safety spectacles with side shields or full-face visor
Protect eyes from splashes during connection/disconnection of dispensing equipment and tank filling operations
BS EN ISO 20345:2011 S5 (steel toecap, penetration-resistant, waterproof)
Chemical-resistant safety footwear
Protect feet from spillages, dropped containers, and contaminated surfaces in bunded storage areas
BS EN 14605:2005 Type 4 (spray-tight protection)
Chemical-resistant apron or coveralls
Prevent clothing contamination and prolonged skin contact during bulk transfer, tank maintenance, and emergency spill response

2. 5×5 Hazard Risk Assessment Matrix (HASAWA 1974 / MHSWR 1999)

Identified Hazard & HarmInitial Risk (L×S)Mandatory Engineering, Isolation & Procedural ControlsResidual Risk
1. Dermal and ocular contact with AdBlue causing skin irritation, drying, and potential eye damage
Harm: Prolonged skin contact causes irritation, dryness, cracking. Eye contact causes stinging, redness, potential corneal damage requiring medical treatment
4 × 2 = 8Mandatory chemical-resistant gloves (BS EN ISO 374-1:2016) and eye protection (BS EN 166:2001) during all dispensing operations. Install hands-free emergency eyewash station within 10 metres of dispensing point (BS EN 15154-2:2006). Provide barrier cream and skin conditioning products. Implement 'no hand contact' dispensing procedures with automatic shut-off nozzles. Post COSHH safety data sheets at point of use.2 × 2 = 4
2. Environmental contamination from AdBlue spillage or tank failure causing watercourse pollution and ammonia release
Harm: Spillage to drains/watercourse causes eutrophication, aquatic toxicity (ammonia breakdown). Environment Agency prosecution, unlimited fines, remediation costs. Soil contamination requiring excavation
3 × 4 = 12Install bunded storage system with minimum 110% tank capacity (Environment Agency PPG2 compliance). Bund constructed from impermeable materials with sealed joints, no drainage outlets. Weekly bund integrity inspections documented in site log. Install overfill prevention system with high-level alarm and automatic pump cut-off. Maintain 50L spill kit within 5 metres. Implement delivery acceptance procedure with driver supervision. Install interceptor on site drainage if required by Environment Agency permit.2 × 3 = 6
3. Inhalation of ammonia vapour from decomposed or heated AdBlue in confined spaces or poorly ventilated areas
Harm: Ammonia exposure causes respiratory irritation, coughing, breathing difficulty, pulmonary oedema at high concentrations (>300ppm). Confined space asphyxiation risk
3 × 3 = 9Store AdBlue below 30°C to prevent thermal decomposition (ISO 22241 requirement). Install temperature monitoring on bulk tanks with high-temperature alarm. Ensure dispensing areas have natural or mechanical ventilation (minimum 5 air changes/hour). Conduct atmospheric testing before entering confined spaces (permit-to-work system). Provide portable ammonia gas detector (0-100ppm range) for tank maintenance. Prohibit storage near heat sources or direct sunlight. Display maximum storage temperature warning signage.2 × 2 = 4
4. Manual handling injuries during AdBlue container movement and dispensing equipment positioning
Harm: Musculoskeletal disorders, back strain, shoulder injuries from lifting 10L/20L containers (10-20kg). Crush injuries from dropped containers
4 × 2 = 8Eliminate manual handling where possible using bulk storage and fixed dispensing systems. Provide mechanical aids (trolleys, drum handlers) for container movement. Implement Manual Handling Operations Regulations 1992 assessment. Restrict manual lifts to maximum 25kg (20kg for female operatives). Provide height-adjustable dispensing platforms to eliminate bending. Train operatives in safe lifting techniques (HSE LITE guidance). Store containers at waist height on designated racking. Use pump systems for 200L IBC containers.2 × 2 = 4
5. Cross-contamination of AdBlue with incompatible substances (diesel, oils, metals) causing product degradation and vehicle SCR system damage
Harm: Contaminated AdBlue causes expensive SCR catalyst poisoning (£2,000-£15,000 repair costs per vehicle). Fleet downtime. Product recall. Customer claims and reputational damage
3 × 3 = 9Segregate AdBlue storage minimum 3 metres from diesel, oils, and chemicals. Use dedicated ISO 22241-compliant dispensing equipment (stainless steel 316, MDPE, polypropylene only). Prohibit use of copper, brass, aluminium, or galvanised steel components. Implement colour-coded identification (AdBlue blue, diesel black). Install physical barriers between AdBlue and fuel dispensing areas. Label all equipment 'AdBlue Only - Do Not Contaminate'. Conduct quarterly ISO 22241 quality testing (urea content, alkalinity, metals). Maintain dedicated cleaning equipment. Implement delivery vehicle inspection procedure.1 × 3 = 3

3. Step-by-Step Safe Sequence of Operations & Hold-Points

1

Conduct pre-dispensing inspection and PPE verification

Pre-Operation Preparation

Verify bund integrity, check for visible leaks, cracks, or contamination. Confirm tank level indicator operational and below 90% capacity. Inspect dispensing hoses for damage, perishing, or contamination. Verify emergency eyewash station functional (weekly flush test). Don mandatory PPE: chemical-resistant gloves (BS EN ISO 374-1:2016), safety spectacles (BS EN 166:2001), chemical-resistant footwear (BS EN ISO 20345:2011 S5), and apron if bulk transfer. Confirm spill kit location and contents. Check weather conditions - do not dispense in high winds or heavy rain.

Critical Hold-Point: STOP: Do not proceed if bund contains standing liquid, tank shows signs of damage, or PPE is unavailable. Report defects immediately to site supervisor and isolate area.
2

Connect dispensing equipment and establish secondary containment

Dispensing Setup

Position drip tray or spill containment mat beneath connection points. Slowly connect dispensing nozzle to receiving vessel, ensuring secure coupling. For bulk tank filling, verify delivery vehicle positioned correctly with handbrake applied and engine off. Confirm delivery hose compatible with ISO 22241 (no copper, brass, or aluminium). Establish communication protocol with delivery driver. Open tank vent valve to prevent vacuum/pressure build-up. Set automatic shut-off volume if applicable. Ensure receiving vessel clearly labelled 'AdBlue Only'.

Critical Hold-Point: HOLD POINT: Verify receiving vessel is empty and clean - any contamination will compromise entire AdBlue stock. Check delivery documentation matches ISO 22241 specification before accepting transfer.
3

Conduct controlled AdBlue transfer with continuous monitoring

Dispensing Operation

Activate dispensing pump at low flow rate initially to verify connections secure. Monitor for leaks at all connection points. Maintain visual contact with receiving vessel throughout operation. For bulk deliveries, remain within 3 metres of emergency shut-off. Monitor tank level indicator and overfill alarm system. Do not leave dispensing operation unattended. Control flow rate to prevent splashing or foaming. For manual dispensing, fill containers to maximum 95% capacity to allow for thermal expansion. Record volume dispensed in site log.

Critical Hold-Point: EMERGENCY STOP: If leak detected, spillage occurs, or overfill alarm activates, immediately shut off pump, close valves, and contain spillage using spill kit. Do not restart until leak source identified and rectified.
4

Safely disconnect equipment and secure containment

Post-Dispensing Shutdown

Close tank inlet valve and allow pressure to equalise (minimum 30 seconds). Slowly disconnect dispensing nozzle over drip tray, allowing residual AdBlue to drain completely. Wipe connection points with clean, lint-free cloth and dispose in designated waste container. Replace tank cap/cover ensuring secure seal. Return dispensing hose to designated storage rack off ground. Close tank vent valve. Inspect bund and immediate area for spillages - clean any drips immediately with water and absorbent materials. Verify overfill alarm system reset.

Critical Hold-Point: CRITICAL: Never leave dispensing equipment connected or tank caps unsecured - contamination risk and environmental exposure. Ensure all valves closed and locked if required by site procedures.
5

Clean equipment and dispose of contaminated materials correctly

Decontamination & Waste Management

Rinse gloves with clean water before removal to prevent skin contact. Remove PPE in correct sequence: gloves, apron, eyewear, footwear (if contaminated). Wash hands thoroughly with soap and water. Clean drip trays and containment equipment with water - AdBlue is water-soluble. Dispose of contaminated absorbent materials as non-hazardous waste (EWC code 15 02 03) unless contaminated with other substances. Rinse any AdBlue splashes on equipment or surfaces immediately with water to prevent crystallisation. Return spill kit to designated location and replenish used materials.

Critical Hold-Point: HEALTH ALERT: If skin irritation or eye contact occurred, irrigate affected area with water for minimum 15 minutes and seek medical advice. Report all exposure incidents to supervisor and record in accident book.
6

Complete records and conduct post-operation inspection

Documentation & Inspection

Record dispensing operation in site log: date, time, volume dispensed, operative name, tank level, any incidents. Update AdBlue stock inventory. Conduct final visual inspection of bund, tank, and dispensing area for leaks or damage. Verify all equipment returned to storage and secured. Check emergency eyewash station not used/contaminated. Review any near-misses or procedural issues with supervisor. Schedule next inspection date (weekly bund inspection, monthly equipment inspection, quarterly ISO 22241 quality test). File COSHH assessment review date (minimum annual or after incident).

Critical Hold-Point: COMPLIANCE: Failure to maintain accurate records may result in Environment Agency enforcement action. Report any environmental release (>10L to ground/drain) to Environment Agency Incident Hotline 0800 807060 immediately.

Emergency Rescue, First Aid & Spill Protocol

**EMERGENCY CONTACTS:** - Emergency Services: 999 - Environment Agency Incident Hotline: 0800 807060 (24/7 for pollution incidents) - Site Supervisor: [Insert contact] - Occupational Health: [Insert contact] **SPILLAGE RESPONSE:** 1. Immediately stop source of spillage - close valves, shut off pump 2. Evacuate non-essential personnel from affected area 3. Prevent spread using absorbent booms or sand barriers 4. Contain spillage within bunded area - do NOT wash to drain 5. Absorb liquid using spill kit granules or sand (AdBlue is water-soluble) 6. Collect contaminated absorbent in sealed containers labelled 'AdBlue Contaminated Waste' 7. If spillage exceeds bund capacity or enters drain/watercourse, immediately notify Environment Agency 0800 807060 8. Ventilate area if ammonia odour detected 9. Decontaminate affected surfaces with water 10. Complete incident report and review COSHH assessment **FIRST AID:** - **Skin Contact:** Remove contaminated clothing. Wash affected area immediately with soap and water for minimum 15 minutes. Apply moisturising cream. If irritation persists, seek medical advice. - **Eye Contact:** Rinse immediately with clean water or eyewash station for minimum 15 minutes, holding eyelids open. Remove contact lenses if present. Seek immediate medical attention - potential corneal damage. - **Inhalation (Ammonia Vapour):** Move casualty to fresh air immediately. Keep warm and at rest. If breathing difficult, administer oxygen if trained. Seek immediate medical attention. Do not enter confined space without BA. - **Ingestion (Unlikely):** Rinse mouth with water. Do NOT induce vomiting. Give water to drink if conscious. Seek immediate medical attention. Provide SDS to medical personnel. **FIRE:** AdBlue is non-flammable. If involved in fire, use water spray, foam, or CO2. Thermal decomposition produces toxic ammonia and nitrogen oxides - wear BA. Cool containers with water spray.

4. UK HSE Compliance FAQs: Commercial AdBlue (ISO 22241 AUS 32 Aqueous Urea Solution) Bulk Storage & Dispensing

Do we legally need bunded storage for AdBlue tanks or can we just put them on a concrete pad with a drain?

Yes, bunded storage is legally required under Environment Agency PPG2 guidelines and Environmental Permitting Regulations 2016. AdBlue must be stored in secondary containment with minimum 110% of tank capacity, constructed from impermeable materials with no drainage outlets. Although AdBlue is not classified as hazardous, spillage to drains or watercourse causes ammonia pollution (from urea breakdown) resulting in environmental damage, prosecution, and unlimited fines. Concrete pads with drains do not provide adequate containment and may connect to surface water drainage. The bund must be inspected weekly and maintained in good condition. Even small-scale storage (200L IBCs) requires containment measures such as spill pallets or bunded IBC stores.

How long can we keep AdBlue in our bulk tank before it goes off and what temperature should we store it at?

AdBlue has a shelf life of 12 months in sealed containers or 6 months in opened/dispensing systems when stored correctly between -11°C and +30°C per ISO 22241 standard. Storage above 30°C accelerates thermal decomposition, producing ammonia vapour and reducing urea concentration below the required 32.5%, which will damage vehicle SCR systems. Storage below -11°C causes crystallisation (freezing point -11°C), though AdBlue returns to specification when thawed slowly. Install temperature monitoring on bulk tanks with high-temperature alarms. Avoid direct sunlight and heat sources. Conduct quarterly ISO 22241 quality testing (urea content, alkalinity, metals content) to verify specification compliance. Implement stock rotation (first-in-first-out) and label tanks with delivery date. Contaminated or out-of-specification AdBlue must be disposed of as non-hazardous waste and cannot be used.

What happens if AdBlue gets mixed with diesel or we use the wrong type of hose and does it damage the dispensing equipment?

Cross-contamination of AdBlue with diesel, oils, or incompatible metals (copper, brass, aluminium) causes catastrophic SCR catalyst poisoning in vehicles, resulting in repair costs of £2,000-£15,000 per vehicle, fleet downtime, and potential customer claims. Even trace contamination (>0.5% diesel) renders AdBlue unusable. Conversely, AdBlue contamination of diesel causes fuel system corrosion and injector damage. Use only ISO 22241-compliant materials: stainless steel 316, MDPE, polypropylene, or PTFE for all storage and dispensing equipment. Copper, brass, aluminium, and galvanised steel cause metallic contamination and accelerate decomposition. Physically segregate AdBlue storage minimum 3 metres from fuels, use dedicated colour-coded equipment (blue for AdBlue), and implement strict 'AdBlue Only' labelling. Install physical barriers between dispensing points. Wrong hose materials will corrode, leach metals into AdBlue, and fail prematurely. Conduct quarterly quality testing and maintain dedicated cleaning equipment to prevent cross-contamination.

5. Operative Toolbox Talk & Competent Person Sign-Off Register

Competent Person & Operative Declaration: By signing below, the Site Supervisor confirms this assessment has been adapted and verified for actual site conditions, and operatives confirm they have attended the pre-start Toolbox Talk for Commercial AdBlue (ISO 22241 AUS 32 Aqueous Urea Solution) Bulk Storage & Dispensing and will follow the safe system of work.

Operative / Supervisor Name Trade / Role & CSCS No. Signature Date & Time
1. (Site Supervisor):     
2.     
3.     
4.     
5.     