This Risk Assessment and Method Statement (RAMS) covers structural steelwork fabrication activities involving angle grinding and MIG (Metal Inert Gas) welding operations. The document addresses key hazards including welding fume exposure (as per HSE INDG463), mechanical hazards from rotating equipment, fire and explosion risks, manual handling, and electrical safety. All activities must comply with PUWER 1998, COSHH 2002, and the Regulatory Reform (Fire Safety) Order 2005. Competent operatives must hold relevant certifications (e.g., coded welder qualifications) and complete task-specific toolbox talks. Local Exhaust Ventilation (LEV) must be provided and tested in accordance with COSHH requirements. Hot work permits are mandatory where specified by site rules. This RAMS applies to fabrication workshops and on-site steelwork operations.
| Identified Hazard & Harm | Initial Risk (L×S) | Mandatory Engineering, Isolation & Procedural Controls | Residual Risk |
|---|---|---|---|
| 1. Welding fume inhalation (hexavalent chromium, manganese, nickel compounds) Harm: Occupational asthma, lung cancer, metal fume fever, chronic respiratory disease |
4 × 5 = 20 | Engineering control: Mobile LEV unit positioned within 300mm of welding arc, tested within 14 months (COSHH). Adequate general ventilation (5-10 air changes/hour). Respiratory protection: FFP3 disposable or powered respirator mandatory. Health surveillance: Welders enrolled in respiratory health surveillance programme. Welding fume awareness training (INDG463). Minimise time in fume cloud - position head away from plume. | 2 × 4 = 8 |
| 2. Contact with rotating grinding disc causing lacerations, entanglement, or disc fragmentation Harm: Severe lacerations, amputations, eye injuries from disc fragments, entanglement of loose clothing |
4 × 4 = 16 | Use only PUWER-compliant grinders with adjustable guards positioned correctly (maximum 180° exposure). Inspect grinding discs pre-use for cracks (ring test). Never exceed rated RPM. Dead-man switch must function correctly. Secure workpiece in vice/clamps - never hand-hold small items. No loose clothing, gloves removed when operating (except when welding). Two-handed operation mandatory. Eye protection (BS EN 166 Grade F) worn at all times. Grinding disc changed by competent person only. | 2 × 3 = 6 |
| 3. Fire and explosion from hot works igniting combustible materials or gases Harm: Burns, smoke inhalation, explosion, property damage, fatalities |
3 × 5 = 15 | Hot Work Permit system enforced (Regulatory Reform Fire Safety Order 2005). Pre-work inspection: remove combustibles within 10m radius or use fire-resistant screens/blankets. Fire extinguishers (CO2 and dry powder) positioned within 5m. Trained fire watcher appointed for duration + 60 minutes post-work. Gas cylinders: flashback arrestors fitted, stored upright, secured, valves closed when not in use. Leak test regulators with soapy water. No smoking within 10m. Oxygen cylinders segregated from fuel gases. Post-work fire watch and sign-off. | 1 × 5 = 5 |
| 4. Electric shock from faulty welding equipment or contact with live conductors Harm: Electrocution, cardiac arrest, burns, secondary injuries from falls |
2 × 5 = 10 | All welding equipment PAT tested and visually inspected before use. Earth clamp securely attached to clean metal surface close to weld zone. Welding cables inspected for damage - no repairs with tape. RCD protection (30mA) on power supply. Dry, insulated gloves worn. Work area kept dry - no welding in wet/damp conditions without additional controls. Lockout/Tagout (LOTO) procedures for maintenance. Only competent electricians to repair equipment. Voltage reduction devices used in confined spaces. | 1 × 5 = 5 |
| 5. Manual handling of heavy steel sections causing musculoskeletal disorders Harm: Back injuries, hernias, strains, sprains, chronic musculoskeletal disorders |
5 × 3 = 15 | Manual Handling Risk Assessment completed. Mechanical aids used wherever practicable: overhead cranes, forklift trucks, pallet trucks, lifting magnets. Team lifts for loads >25kg (individual) or >20kg (repetitive). Kinetic lifting technique training provided. Work at waist height where possible - use adjustable welding benches/positioners. Clear access routes maintained. Pre-shift stretching encouraged. Rotate tasks to avoid prolonged static postures. Report early symptoms of discomfort to supervisor. | 3 × 2 = 6 |
Obtain and review Hot Work Permit if required by site rules. Conduct toolbox talk covering hazards, controls, and emergency procedures. Inspect all tools and equipment: grinders (guard, switch, cable), welding set (earth clamp, cables, torch), LEV unit (airflow test), gas cylinders (secure, flashback arrestors fitted). Check PAT test labels are in date. Clear work area of combustibles within 10m radius or erect fire-resistant screens. Position fire extinguishers within 5m. Appoint fire watcher. Erect welding screens and warning signage ('Welding in Progress - Arc Eyes Risk'). Ensure adequate ventilation or position mobile LEV unit.
Put on all mandatory PPE: FFP3 respirator (fit-check performed), welding helmet with auto-darkening filter, leather welding gauntlets, safety boots S3, flame-resistant coveralls, and hearing protection if noise >85dB(A). Position mobile LEV extraction hood within 300mm of planned welding arc location. Switch on LEV and verify airflow (visual check or airflow indicator). Secure workpiece in vice, clamps, or on welding bench - never hand-hold. Ensure earth clamp is attached to clean metal surface close to weld zone.
Inspect grinding disc for cracks (perform ring test by suspending disc and tapping - should ring clearly). Ensure disc RPM rating exceeds grinder speed. Fit disc securely and adjust guard to maximum protection (180° exposure maximum). Secure workpiece. Adopt stable stance with two-handed grip. Switch on grinder and allow to reach full speed before contact. Apply moderate pressure - let the tool do the work. Maintain guard between operator and disc. Keep sparks directed away from self and others. Allow grinder to stop fully before setting down. Replace worn discs promptly.
Clean joint area with wire brush to remove mill scale, rust, and contaminants. Set welding parameters (voltage, wire feed speed, gas flow 12-15 L/min) according to material thickness and welding procedure specification (WPS). Perform gas leak test on regulator connections. Position LEV hood close to arc. Lower welding helmet. Strike arc and maintain correct torch angle (push technique 5-15° for MIG). Use smooth, consistent travel speed. Avoid breathing fume - position head to side of plume. Allow weld to cool naturally - do not quench. Chip slag and inspect weld visually for defects.
Allow welded component to cool to safe handling temperature (use thermal imaging or touch test with back of gloved hand). Inspect weld for defects: cracks, porosity, undercut, lack of fusion. Mark any defects for rework. Perform secondary grinding to dress welds flush if required by specification. Use same grinding safety controls as Step 3. Remove sharp edges and burrs. Clean work area of hot metal debris and grinding swarf. Check for smouldering materials.
Switch off welding set and grinder. Close gas cylinder valves and release pressure from regulators. Disconnect earth clamp. Coil cables and hoses neatly to prevent trip hazards. Switch off and reposition LEV unit. Conduct thorough area inspection for hot metal, sparks, or smouldering materials - check under benches and in cracks. Fire watcher to remain on station for minimum 60 minutes post-work, monitoring for signs of fire. Complete Hot Work Permit sign-off. Remove welding screens and signage. Store equipment securely. Report any equipment defects or near-misses to supervisor.
**Emergency Contacts:** Site Emergency: [Insert site-specific number]. Fire Brigade: 999. First Aiders: [Insert names/locations]. Nearest A&E: [Insert hospital details]. **Fire/Explosion:** Activate fire alarm. Evacuate area immediately. Close gas cylinder valves if safe to do so. Use CO2 or dry powder extinguisher on small fires only if trained. Do not use water on electrical or metal fires. Muster at assembly point. Do not re-enter until cleared by Fire Service. **Electric Shock:** Do NOT touch casualty if still in contact with electricity. Isolate power source or use non-conductive material to break contact. Call 999 immediately. If trained and safe, commence CPR. Use AED if available. Treat for shock and burns. **Arc Eye (Photokeratitis):** Symptoms appear 3-12 hours post-exposure: gritty sensation, pain, watering, light sensitivity. Remove contact lenses. Do not rub eyes. Apply cold compress. Seek medical attention - attend A&E or occupational health. Prevent by ensuring all personnel wear correct eye protection. **Welding Fume Exposure:** Move casualty to fresh air immediately. Loosen tight clothing. If unconscious, place in recovery position. If breathing difficulties, administer oxygen if trained. Call 999. Monitor for delayed symptoms (metal fume fever: flu-like symptoms 4-12 hours post-exposure). Report incident and review LEV effectiveness. **Burns (Thermal/Molten Metal):** Cool burn under running cold water for 20 minutes minimum. Remove jewellery/watches before swelling occurs. Do not remove clothing stuck to burn. Cover with sterile non-adhesive dressing or cling film. For burns >5cm or deep burns, call 999. Treat for shock. Do not apply creams or ointments. **Grinding Disc Injury/Laceration:** Apply direct pressure with clean cloth. Elevate injured limb. Call 999 for severe bleeding or suspected fractures. Do not remove embedded fragments. Preserve severed parts in clean bag on ice (not direct contact). All injuries requiring stitches must attend A&E. **Incident Reporting:** All accidents, near-misses, and dangerous occurrences must be reported immediately to site supervisor and recorded in accident book. RIDDOR-reportable injuries (>7 days off work, specified injuries) must be reported to HSE within required timescales.
Under COSHH 2002, employers must prevent or adequately control exposure to welding fume, which is classified as a Group 1 carcinogen (IARC). HSE guidance INDG463 (updated 2019) emphasises that welding fume must be controlled to a level as low as reasonably practicable, with engineering controls (LEV) as the primary method. General ventilation alone is insufficient. LEV must be positioned within 300mm of the arc, tested every 14 months by a competent person (COSHH Regulation 9), and records kept for 5 years. Respiratory Protective Equipment (RPE) is required as secondary protection - minimum FFP3 for MIG welding mild steel. Health surveillance (respiratory questionnaires, spirometry) is mandatory for regular welders. The change reflects growing evidence linking welding fume to lung cancer and other serious respiratory diseases. Failure to comply can result in prosecution, improvement/prohibition notices, and civil claims.
A Hot Work Permit is required under the Regulatory Reform (Fire Safety) Order 2005 whenever welding, grinding, or other hot work is conducted outside designated fabrication areas, or where there is increased fire risk (e.g., near combustibles, in occupied buildings, on sites with flammable materials). The permit system ensures a competent person has assessed fire risks and implemented controls. Key permit elements include: (1) Confirmation that work cannot be done by cold methods; (2) Removal of combustibles within 10m or use of fire-resistant barriers; (3) Provision of suitable fire extinguishers within 5m; (4) Appointment of trained fire watcher for duration + 60 minutes post-work; (5) Isolation of fire detection systems if necessary (with compensatory measures); (6) Gas cylinder safety checks (flashback arrestors, secure storage, leak tests); (7) Confirmation of operator competence; (8) Emergency contact details. The permit must be signed by the person doing the work, the permit issuer, and the fire watcher. Post-work inspection and sign-off is mandatory. Permits are typically valid for one shift only and must be reissued daily.
Under PUWER 1998, angle grinders must be suitable for the task, maintained in safe condition, and inspected regularly. Pre-use checks must include: guard securely fitted and correctly adjusted (maximum 180° disc exposure), dead-man switch functioning, no damage to cables/plug, PAT test in date. Grinding discs must be inspected for cracks, chips, or damage before fitting - perform a 'ring test' by suspending the disc and tapping (damaged discs sound dull). Never exceed the disc's maximum RPM rating. Discs must be stored flat in dry conditions. Main causes of grinding accidents include: (1) Disc fragmentation due to excessive speed, side loading, or using damaged discs; (2) Contact injuries from removed/incorrectly adjusted guards; (3) Kickback from binding or snagging; (4) Eye injuries from flying particles (lack of eye protection); (5) Entanglement of loose clothing or gloves. Only competent, trained operatives should use grinders. Two-handed operation is mandatory. Workpieces must be securely clamped - never hand-held. Grinders must be allowed to stop fully before setting down. Any defects must be reported immediately and equipment taken out of service until repaired by a competent person.
Competent Person & Operative Declaration: By signing below, the Site Supervisor confirms this assessment has been adapted and verified for actual site conditions, and operatives confirm they have attended the pre-start Toolbox Talk for Structural Steelwork Angle Grinding & MIG Welding and will follow the safe system of work.
| Operative / Supervisor Name | Trade / Role & CSCS No. | Signature | Date & Time |
|---|---|---|---|
| 1. (Site Supervisor): | |||
| 2. | |||
| 3. | |||
| 4. | |||
| 5. | |||
| 6. |