This COSHH assessment addresses the storage, handling, and use of oxy-acetylene compressed gas cylinders in accordance with DSEAR 2002, BCGA Code of Practice CP7, and COSHH 2002. Oxygen (GHS03 oxidising) and acetylene (GHS02 extremely flammable, GHS04 compressed gas, H220) present significant fire, explosion, and asphyxiation hazards. Controls include segregated storage (minimum 3m separation), mandatory flashback arrestors on both oxygen and acetylene lines, cylinder restraint, competent person training, hot work permits, and emergency procedures. All operatives must hold valid certification and follow BCGA guidance. This document ensures compliance with UK HSE enforcement expectations and reduces residual risk to tolerable levels through engineered controls and safe systems of work.
| Identified Hazard & Harm | Initial Risk (L×S) | Mandatory Engineering, Isolation & Procedural Controls | Residual Risk |
|---|---|---|---|
| 1. Fire and explosion from acetylene decomposition or oxygen-enriched atmosphere Harm: Catastrophic explosion, severe burns, multiple fatalities, property destruction | 4 × 5 = 20 | Segregate oxygen and acetylene cylinders by minimum 3m or fire-resistant partition (30-min rated). Install flashback arrestors to BS EN ISO 5175:2017 on both gases at cylinder regulator and torch inlet. Acetylene pressure never to exceed 0.62 bar (gauge). Store cylinders upright, valve-end up, in well-ventilated area away from ignition sources (minimum 3m). Hot work permit system with fire watch. Prohibit smoking, naked flames, and electrical equipment not rated ATEX in storage/use zones. Daily visual inspection of hoses for damage/degradation. | 2 × 4 = 8 |
| 2. Flashback into cylinder causing rupture Harm: Cylinder explosion, fragmentation injuries, fatalities within 10m radius | 3 × 5 = 15 | Mandatory dual flashback arrestors: one at cylinder regulator outlet and one at torch inlet (BCGA CP7 requirement). Arrestors must be BS EN ISO 5175:2017 certified and inspected every 6 months. Ensure torch is fitted with integral non-return valves. Correct lighting-up and shutdown sequence (acetylene first on, last off for lighting; reverse for shutdown). Never use damaged or kinked hoses. Immediate shutdown if flashback occurs—close cylinder valves, allow arrestor to cool, inspect before reuse. | 1 × 5 = 5 |
| 3. Asphyxiation from oxygen displacement or oxygen deficiency Harm: Unconsciousness, brain damage, death within minutes | 3 × 5 = 15 | Store cylinders in well-ventilated area (natural or mechanical ventilation achieving 5 air changes/hour minimum). Install oxygen depletion monitors in enclosed storage areas (alarm set at 19.5% O₂). Never enter confined spaces where gas may accumulate without gas testing and permit-to-work. Cylinders to be stored upright and secured to prevent valve damage. Emergency ventilation procedures and rescue plan in place. Signage: 'Danger—Compressed Gases—Asphyxiation Risk'. | 1 × 5 = 5 |
| 4. High-pressure gas release causing cylinder projectile or whipping hose Harm: Severe impact injuries, lacerations, fractures, fatalities from uncontrolled cylinder movement | 3 × 4 = 12 | Secure all cylinders upright with chains or purpose-built restraints at all times (storage, transport, use). Use cylinder trolleys with restraint straps for movement. Fit hose restraint clips at all connections. Open cylinder valves slowly (quarter-turn maximum initially). Never use damaged or out-of-test cylinders (check test date stamp). Regulators and valves to be compatible with gas service (oxygen-clean for O₂). Pressure relief devices must not be tampered with. Operatives trained in emergency shutdown procedures. | 1 × 4 = 4 |
| 5. Incompatible materials causing ignition (oil/grease contact with oxygen) Harm: Spontaneous combustion, severe burns, equipment destruction | 4 × 4 = 16 | Oxygen equipment must be 'oxygen-clean' (free from hydrocarbons). Never use oil, grease, or petroleum-based products on oxygen cylinders, valves, regulators, or fittings. Use only oxygen-compatible lubricants if required (BCGA approved). Operatives to have clean, oil-free gloves when handling oxygen equipment. Separate storage and handling areas for oxygen and fuel gases. Dedicated spanners/tools for oxygen service only (marked and segregated). Pre-use inspection checklist to verify cleanliness. | 2 × 3 = 6 |
Verify cylinders are in-test (check test date stamp—10-year interval for acetylene, 5-year for oxygen). Inspect cylinders for damage, corrosion, or leaks. Check flashback arrestors are fitted at both cylinder regulator and torch inlet, and are within 6-month inspection date. Inspect hoses for cracks, burns, or degradation (replace if suspect). Confirm hot work permit is valid and fire extinguishers (minimum 9kg CO₂ or powder) are within 5m. Ensure area is clear of flammable materials within 10m radius.
Position cylinders upright and secure with chains/restraints minimum 1m apart. Remove valve protection caps. Briefly crack open cylinder valves to clear dust (stand to side, never in front). Attach oxygen regulator to oxygen cylinder (right-hand thread) and acetylene regulator to acetylene cylinder (left-hand thread—notched nut). Tighten with correct spanner (never use grips). Connect hoses: oxygen (blue/black) to right, acetylene (red) to left. Fit flashback arrestors at regulator outlets. Open cylinder valves slowly—oxygen fully open, acetylene maximum 1.5 turns. Set working pressures: oxygen 2-4 bar, acetylene maximum 0.62 bar.
Open acetylene torch valve quarter-turn and ignite gas with spark lighter (never matches or cigarette lighter). Adjust acetylene to eliminate smoke. Gradually open oxygen valve to achieve neutral flame (sharp inner cone). Adjust for work type: neutral for welding, slightly oxidising for cutting. Monitor flame stability. If flame pops back into torch, immediately close both cylinder valves and investigate cause before relighting.
Maintain correct flame adjustment throughout work. Keep hoses away from hot work area and sharp edges. Never place hoses where they can be run over or damaged. Monitor for signs of flashback (popping, squealing, or flame inside torch). Ensure adequate ventilation—fumes from galvanised or coated materials require LEV or RPE. Fire watch to monitor for ignition of surrounding materials. Do not leave lit torch unattended. If work is interrupted, shut down equipment using correct sequence.
Close acetylene torch valve first, then oxygen torch valve (reverse of lighting sequence). Close acetylene cylinder valve, then oxygen cylinder valve. Open torch valves to release residual pressure from hoses and regulators (gauges should read zero). Close torch valves. Release regulator adjusting screws (turn counter-clockwise until loose). Leave flashback arrestors in place. Replace valve protection caps on cylinders.
Inspect hoses and equipment for damage sustained during use. Coil hoses loosely (avoid kinks) and store away from direct sunlight and heat sources. Return cylinders to designated storage area—segregate oxygen and acetylene by 3m minimum or fire-resistant partition. Secure cylinders upright with valve protection caps fitted. Record cylinder usage and remaining contents. Complete hot work permit sign-off. Ensure fire extinguishers are recharged if used. Report any equipment defects or near-miss incidents via company reporting system.
**Fire Involving Cylinders:** Evacuate area immediately and call emergency services (999). If safe to do so without risk, close cylinder valves to stop gas flow. Do not approach cylinders involved in fire—risk of BLEVE (Boiling Liquid Expanding Vapour Explosion). Establish 100m exclusion zone. Use water spray to cool surrounding cylinders from maximum distance or behind substantial cover. If acetylene cylinder is involved in fire or becomes hot, evacuate and do not approach for minimum 24 hours. **Gas Leak:** Eliminate all ignition sources. Evacuate area if large leak. If safe, close cylinder valve. Ventilate area. Use leak detection solution to locate small leaks. Do not attempt repairs—isolate cylinder and contact supplier. **Flashback Event:** Immediately close both cylinder valves. Allow flashback arrestor to cool (minimum 10 minutes). Inspect arrestor, hoses, and torch for damage. Do not reuse if any component is damaged—replace and test before resuming work. **Asphyxiation/Oxygen Deficiency:** Remove casualty to fresh air immediately (use BA if atmosphere is unsafe). Call 999. Administer oxygen if trained and available. Commence CPR if not breathing. Do not enter oxygen-deficient atmosphere without appropriate RPE and rescue plan. **Burns:** Cool burn with running water for minimum 20 minutes. Remove jewellery/tight clothing before swelling occurs. Cover with sterile non-adherent dressing. Seek medical attention for all burns beyond superficial. **First Aiders:** Minimum one appointed person trained to HSE First Aid at Work standard must be present during oxy-acetylene operations. First aid kit to include burns dressings and eye wash.
BCGA Code of Practice CP7 mandates dual flashback arrestors to provide redundant protection against flame travelling back into cylinders, which could cause catastrophic explosion. Arrestors at the cylinder regulator protect the primary gas supply, while torch-end arrestors provide secondary protection if the torch's integral non-return valves fail. Flashback arrestors must be inspected every 6 months by a competent person and replaced if the thermal cut-off has activated or if there is any visible damage. They must comply with BS EN ISO 5175:2017 and be suitable for the specific gas service (oxygen or acetylene). Never bypass or remove flashback arrestors—this is a fundamental breach of DSEAR 2002 and BCGA guidance.
Acetylene must never exceed 0.62 bar (gauge) or 1.5 bar absolute pressure in the free state. Above this pressure, acetylene becomes unstable and can spontaneously decompose with explosive violence, even without oxygen present. This is why acetylene cylinders contain a porous mass soaked in acetone—the acetylene is dissolved in the acetone, allowing safe storage at higher pressures (up to 15 bar in the cylinder). When drawn off, the pressure must be regulated to below 0.62 bar. Regulators must be set correctly and never adjusted to exceed this limit. This is a critical DSEAR 2002 requirement and non-compliance has resulted in fatal incidents.
Oxygen (oxidiser) and acetylene (fuel) must be segregated by minimum 3 metres or a 30-minute fire-resistant partition to prevent a fire involving one gas from propagating to the other, which would create an explosive fuel-oxidiser mixture. DSEAR 2002 requires dangerous substances to be stored in designated areas with appropriate controls: outdoor storage is preferred; if stored indoors, the area must be well-ventilated (minimum 5 air changes/hour), away from ignition sources, with appropriate signage (DSEAR zoning), and emergency procedures in place. Cylinders must be upright, secured, protected from physical damage and weather extremes (below 50°C), and segregated from incompatible materials. Full and empty cylinders must be stored separately. This segregation is enforced by HSE and failure to comply can result in prohibition notices and prosecution.
Competent Person & Operative Declaration: By signing below, the Site Supervisor confirms this assessment has been adapted and verified for actual site conditions, and operatives confirm they have attended the pre-start Toolbox Talk for Oxy-Acetylene Compressed Gas Cylinders Storage, Flashback Arrestors & Use and will follow the safe system of work.
| Operative / Supervisor Name | Trade / Role & CSCS No. | Signature | Date & Time |
|---|---|---|---|
| 1. (Site Supervisor): | |||
| 2. | |||
| 3. | |||
| 4. | |||
| 5. | |||
| 6. |