SafeSequence › UK Safety Template Library › COSHH & Chemical Safety › Water-Mix Metalworking Fluid (MWF) Sump Oil Mist & Endotoxin Control
Verified UK COSHH Standard • COSHH & Chemical Safety

Water-Mix Metalworking Fluid (MWF) Sump Oil Mist & Endotoxin Control (COSHH Template & 5x5 Risk Assessment)

This COSHH assessment addresses the health hazards associated with water-mix metalworking fluids (MWFs), specifically focusing on sump maintenance, oil mist exposure control, and bacterial/endotoxin contamination. Water-mix MWFs can harbour bacteria, fungi, and endotoxins which pose respiratory sensitisation, dermatitis, and occupational asthma risks. This document complies with COSHH 2002 (as amended), HSE INDG365 (Metalworking Fluids: Health Risks and Precautions), and incorporates dip-slide bacterial monitoring protocols. Engineering controls including local exhaust ventilation (LEV), regular fluid maintenance, biocide dosing, and exposure monitoring are mandated. All operatives must be trained in MWF hazards, skin surveillance programmes, and emergency decontamination procedures. This assessment must be reviewed every 12 months or following any process change, ill-health report, or monitoring exceedance.

Statutory FrameworkCOSHH 2002, HSE INDG365 & MWF Guidance, Dip-Slide Bacterial Monitoring
ClassificationWater-mix metalworking fluids are typically classified as mixtures under CLP/GHS. Concentrate formulations may contain: Triethanolamine (CAS 102-71-6, Skin Sens. 1B, H317), Formaldehyde-releasing biocides (Skin Sens. 1, H317; Carc. 1B, H350), Boron compounds (Repr. 1B, H360FD). Diluted in-use fluids typically exhibit pH 8.5-9.5. Bacterial contamination produces endotoxins (lipopolysaccharides) which are not GHS-classified but pose significant respiratory hazards. Refer to supplier SDS for specific concentrate hazards. Workplace Exposure Limits (WELs): Oil mist (mineral) 5 mg/m³ 8-hr TWA, 10 mg/m³ 15-min STEL (EH40/2005). No specific WEL for endotoxins; HSE recommends <50 EU/m³ as action level based on Dutch Expert Committee guidance.
Required Plant / KitDip-slide bacterial test kits (e.g. Hygiena InSite or equivalent, calibrated for MWF bacteria/fungi) • Calibrated pH meter or pH test strips (range 7.0-11.0) with traceability certificate • Refractometer (Brix scale 0-32%) for concentration monitoring, calibrated to ±0.1% • Local Exhaust Ventilation (LEV) system with COSHH-compliant extraction hoods and F7-rated filters, LEV examination certificate valid (14-month intervals) • Lockout/Tagout (LOTO) kit including machine isolation locks, danger tags, and permit-to-work documentation
Review Cycle12 Months / Post-Incident
Instant AI Customization or Free Blank Word (.doc) Download

Need this COSHH customized with your Company Name, Site Postcode & Nearest A&E Hospital?

Dictate your site specifics on your phone in 45 seconds to auto-compile a signed PDF—or download our free blank Word (.doc) shell below.

Auto-Fill via Voice / CLP (45s)

2. 5×5 Hazard Risk Assessment Matrix (HASAWA 1974 / MHSWR 1999)

Identified Hazard & HarmInitial Risk (L×S)Mandatory Engineering, Isolation & Procedural ControlsResidual Risk
1. Inhalation of oil mist aerosols and endotoxin-containing bioaerosols from contaminated MWF
Harm: Occupational asthma, hypersensitivity pneumonitis, chronic bronchitis, COPD exacerbation, flu-like symptoms (Monday morning fever)
4 × 4 = 16Install and maintain LEV with capture velocity ≥1 m/s at source (COSHH Essentials Sheet MWF1). LEV thorough examination every 14 months per HSG258. Personal air sampling for oil mist and endotoxin quarterly. Maintain bacterial count <10⁵ CFU/ml via weekly dip-slide testing. Biocide dosing per manufacturer protocol. Machine enclosure where practicable. RPE (FFP3) if exposure >50 EU/m³ endotoxin or >5 mg/m³ oil mist.2 × 3 = 6
2. Dermal contact with contaminated MWF causing skin sensitisation and irritant contact dermatitis
Harm: Allergic contact dermatitis, irritant dermatitis, folliculitis, oil acne, skin infections, potential systemic sensitisation
5 × 3 = 15Eliminate direct hand immersion in MWF via process redesign. Provide nitrile gloves (BS EN 374-1 Type B minimum). Skin surveillance programme (HSE INDG306) with pre-placement and 6-monthly checks. Provide COSHH-compliant skin cleansers (pH-neutral, fragrance-free) and moisturisers. Prohibit use of solvents/abrasives for skin cleaning. Immediate washing facilities within 10m of workstation. Toolbox talks on skin care.3 × 2 = 6
3. Bacterial and fungal contamination (Pseudomonas, Mycobacterium, Fusarium spp.) producing endotoxins
Harm: Respiratory sensitisation, extrinsic allergic alveolitis, systemic infection (immunocompromised workers), endotoxin shock syndrome
4 × 4 = 16Weekly dip-slide monitoring with action level <10⁴ CFU/ml bacteria, <10³ CFU/ml fungi (HSE RR922). Maintain pH 8.8-9.2 and concentration per manufacturer spec (refractometer check daily). Biocide dosing when bacterial count exceeds action level. Full sump clean-out every 3-6 months or when bacterial control lost. Remove tramp oil daily via skimmer/coalescer. Prevent external contamination (covers on sumps when idle). Quarterly endotoxin air sampling.2 × 3 = 6
4. Exposure to biocides (formaldehyde-releasers, isothiazolinones) during dosing and maintenance
Harm: Skin sensitisation (H317), respiratory sensitisation, chemical burns, potential carcinogenicity (formaldehyde Carc. 1B)
3 × 4 = 12Substitute to lowest-hazard biocide system (avoid formaldehyde-releasers where practicable). Automated biocide dosing systems to eliminate manual handling. If manual dosing required: use closed transfer systems, wear nitrile gloves + goggles + apron, dose in well-ventilated area or under LEV. Store biocides in locked COSHH cabinet with secondary containment. Measure biocide concentration weekly to prevent over-dosing. Health surveillance for skin/respiratory sensitisation.2 × 3 = 6
5. Machine entanglement and contact with rotating parts during sump maintenance without isolation
Harm: Amputation, crushing injuries, lacerations, entanglement fatalities
3 × 5 = 15Mandatory LOTO procedure per BS EN ISO 14118:2018 before any sump access. Isolate electrical supply and apply personal padlock. Dissipate stored energy (hydraulic/pneumatic). Verify zero energy state with test instrument. Display 'Danger - Do Not Operate' tags. Permit-to-work system for sump entry/cleaning. Toolbox talk on LOTO before each maintenance session. Disciplinary procedure for LOTO non-compliance. Annual LOTO competency assessment.1 × 5 = 5

3. Step-by-Step Safe Sequence of Operations & Hold-Points

1

Conduct pre-task briefing, review SDS, and verify LEV operation

Pre-Work Preparation & Risk Assessment

Hold toolbox talk covering MWF hazards (dermatitis, respiratory sensitisation, endotoxin exposure) and emergency procedures. Review supplier SDS for concentrate and in-use fluid. Check LEV system is operational (indicator lights, airflow gauge reading within green zone). Verify dip-slide results from previous week; if bacterial count >10⁵ CFU/ml, escalate to full sump clean-out procedure. Confirm all operatives have completed MWF health surveillance and are fit for task. Ensure emergency eyewash station is functional (weekly flush test record checked).

Critical Hold-Point: STOP: Do not proceed if LEV system is non-operational or overdue 14-month thorough examination. Do not proceed if any operative has active dermatitis or respiratory symptoms without Occupational Health clearance.
2

Isolate machine tool and apply Lockout/Tagout (LOTO) controls

Machine Isolation & LOTO

Identify all energy sources (electrical, pneumatic, hydraulic). Switch machine to OFF and isolate at main electrical isolator. Apply personal padlock and 'Danger - Do Not Operate' tag to isolator. Dissipate residual energy (bleed pneumatic lines, lower hydraulic pressure). Attempt to restart machine to verify zero energy state (test button press - must not operate). Complete LOTO permit-to-work form with date, time, operative name, and isolation points. Retain key in personal possession. Inform shift supervisor of isolation.

Critical Hold-Point: HOLD POINT: Verify zero energy state before proceeding. Do not rely on machine controls alone - physical isolation mandatory. Each operative must apply their own personal lock (group LOTO if multiple workers).
3

Perform dip-slide bacterial test, pH, and concentration measurements

Monitoring & Testing

Don nitrile gloves and safety goggles. Remove dip-slide from sterile packaging without touching agar surfaces. Immerse slide fully in MWF sump for 5 seconds, ensuring both sides wetted. Drain excess fluid and replace in tube. Label with date, time, sump ID, and operative initials. Incubate at room temperature (20-25°C) for 48 hours per manufacturer instructions. Measure pH using calibrated meter (target 8.8-9.2). Measure concentration using refractometer (compare to manufacturer specification, typically 5-10% for water-mix MWF). Record all results in MWF Monitoring Log.

Critical Hold-Point: CRITICAL: If pH <8.5 or bacterial count from previous test >10⁵ CFU/ml, do not add fresh concentrate - sump must be fully cleaned and recharged. Contaminated fluid cannot be 'rescued' by dilution.
4

Remove tramp oil, adjust concentration, and dose biocide if required

Fluid Maintenance & Biocide Dosing

Use surface skimmer or coalescer to remove tramp oil (hydraulic oil, slideway oil contamination). Dispose of tramp oil as hazardous waste per site EWC code. If concentration low, add MWF concentrate using closed transfer system or dosing pump - never add concentrate directly to sump without pre-mixing with water (exothermic reaction risk). If bacterial count 10⁴-10⁵ CFU/ml, dose biocide per manufacturer protocol (typically 0.1-0.2% v/v). Wear additional apron during biocide handling. Mix thoroughly using sump circulation pump (run for 15 minutes). Retest pH and concentration after 1 hour.

Critical Hold-Point: WARNING: Always add concentrate to water, never water to concentrate (heat generation and splashing risk). Biocides are hazardous - avoid skin contact and inhalation. Use automated dosing where available.
5

Perform full sump drain, clean, and recharge (quarterly or when contaminated)

Sump Clean-Out (if required)

If bacterial control lost or scheduled clean-out due: pump out all MWF to designated waste container (hazardous waste - EWC 12-01-09). Manually remove swarf and sludge using non-sparking tools. Clean all sump surfaces with alkaline cleaner (pH 10-11) and scrub with brushes. Rinse thoroughly with clean water. Inspect for corrosion, leaks, or biofilm. If biofilm present, treat with biocidal cleaner and rinse again. Allow to dry or wipe with lint-free cloths. Recharge sump with fresh MWF mixed to correct concentration. Run circulation pump for 30 minutes. Perform initial dip-slide test after 24 hours.

Critical Hold-Point: HOLD POINT: Confined space assessment required if sump depth >1.2m or access restricted. Ensure adequate ventilation during cleaning (endotoxin aerosol risk). Wear FFP3 respirator during sludge removal and scrubbing.
6

Remove LOTO, restore machine, and complete records

Restoration & Documentation

Ensure all tools and cleaning materials removed from machine area. Replace sump covers and guards. Remove LOTO tag and personal padlock from isolator. Restore electrical supply. Perform machine function test (jog mode) to verify normal operation. Update MWF Monitoring Log with all test results, maintenance actions, and biocide dosing. File dip-slide results (photograph or retain physical slide for 3 years). Report any adverse trends (rising bacterial counts, pH drift) to supervisor. Clean and store all PPE (wash reusable gloves, dispose of contaminated disposables as hazardous waste). Wash hands and forearms thoroughly with pH-neutral cleanser and apply moisturiser.

Critical Hold-Point: FINAL CHECK: Confirm all guards replaced and machine safe to operate before removing LOTO. Incomplete records are a COSHH compliance failure - ensure all monitoring data logged before leaving workstation.

Emergency Rescue, First Aid & Spill Protocol

**EMERGENCY CONTACTS:** First Aider: [Insert name/ext], Occupational Health: [Insert contact], Emergency Services: 999 (state 'chemical exposure' or 'respiratory distress'). **EYE CONTACT:** Immediately irrigate eyes at emergency eyewash station for minimum 15 minutes, holding eyelids open. Remove contact lenses if present and easy to do. Seek immediate medical attention - MWF eye exposure can cause corneal damage and infection. Bring SDS to A&E. **SKIN CONTACT:** Remove contaminated clothing immediately. Wash affected area with copious lukewarm water and pH-neutral soap for minimum 10 minutes. Do NOT use solvents, abrasives, or hot water (increases absorption). Pat dry gently. If irritation, redness, or itching develops, report to Occupational Health same day - may indicate sensitisation. **INHALATION:** Move casualty to fresh air immediately. If respiratory distress, wheezing, or chest tightness occurs, call 999 and administer oxygen if trained. Sit casualty upright. Monitor for delayed symptoms (extrinsic allergic alveolitis can present 4-6 hours post-exposure). Do not allow return to work - medical assessment mandatory. **INGESTION:** Rinse mouth with water. Do NOT induce vomiting. Give small amounts of water to drink if conscious. Seek immediate medical attention. Bring SDS and note biocide type if recently dosed. **SPILLAGE:** Isolate area and prevent access. Wear full PPE (gloves, goggles, apron, FFP3 if aerosol generated). Absorb with inert material (vermiculite, sand). Dispose as hazardous waste (EWC 12-01-09). Ventilate area. Decontaminate floor with alkaline cleaner. Report all spills >10L to Environment Agency (0800 807060). **REPORTING:** All MWF-related ill-health (dermatitis, respiratory symptoms, 'Monday morning fever') must be reported to Occupational Health within 24 hours. Occupational asthma and dermatitis are RIDDOR-reportable diseases - notify HSE via online portal within 10 days of diagnosis.

4. UK HSE Compliance FAQs: Water-Mix Metalworking Fluid (MWF) Sump Oil Mist & Endotoxin Control

What is the HSE-recommended action level for bacterial contamination in water-mix MWFs, and what should I do if dip-slide results exceed this?

HSE Research Report RR922 recommends an action level of 10⁴ CFU/ml for bacteria and 10³ CFU/ml for fungi in water-mix MWFs. If your dip-slide results exceed 10⁴ but remain below 10⁵ CFU/ml, immediate biocide dosing per manufacturer protocol is required, followed by retesting within 48 hours. If bacterial counts exceed 10⁵ CFU/ml (or fungi >10⁴ CFU/ml), the fluid is considered 'out of control' and a full sump clean-out and recharge is mandatory - biocide dosing alone will not restore control. Additionally, if any workers report respiratory symptoms or dermatitis, or if endotoxin air sampling exceeds 50 EU/m³, immediate action is required regardless of dip-slide results. Document all exceedances and corrective actions in your COSHH monitoring records, and review your maintenance frequency to prevent recurrence.

How often must LEV systems for MWF mist control be examined, and what are the legal requirements under COSHH?

Under COSHH Regulation 9 and HSG258 (Controlling Airborne Contaminants at Work), LEV systems used to control MWF mist and bioaerosol exposure must undergo a 'thorough examination and test' (TExT) by a competent person at intervals not exceeding 14 months. This is a legal requirement, not a recommendation. The examination must verify capture velocity at source (typically ≥1 m/s for MWF applications per COSHH Essentials Sheet MWF1), duct velocity, filter condition, and overall system performance. A written report (P601 or equivalent) must be produced and retained for 5 years. Between formal examinations, operators should perform daily visual checks (indicator lights, airflow gauges) and report any defects immediately. If LEV is found to be ineffective or overdue examination, work involving MWF must cease until remedial action is completed and the system is re-certified. Failure to maintain LEV is a common HSE enforcement issue and can result in Improvement Notices or prosecution under Section 33 HSWA.

Are there specific health surveillance requirements for workers exposed to MWFs, and what should trigger a referral to Occupational Health?

Yes, health surveillance is mandatory under COSHH Regulation 11 for workers exposed to MWFs due to the risk of occupational asthma, dermatitis, and respiratory sensitisation. HSE INDG306 (Health Surveillance at Work) and INDG365 (Metalworking Fluids) specify that surveillance should include: (1) Pre-placement assessment to identify susceptible individuals (pre-existing asthma, eczema, atopy); (2) Periodic skin inspections (minimum 6-monthly, more frequently if dermatitis cases occur); (3) Respiratory symptom questionnaires (annually or when symptoms reported); (4) Lung function testing (spirometry) if respiratory symptoms develop. Immediate Occupational Health referral is required if a worker reports: persistent cough, wheeze, chest tightness (especially if worse at work and improving on days off - classic occupational asthma pattern), skin rash, itching, or cracking on hands/forearms, or 'Monday morning fever' (flu-like symptoms at start of working week, indicating endotoxin exposure). Occupational asthma and dermatitis caused by MWFs are prescribed diseases under RIDDOR Schedule 3 (asthma: agent causing sensitisation; dermatitis: substance capable of causing skin sensitisation) and must be reported to HSE. Early detection through surveillance is critical - established occupational asthma often requires permanent removal from exposure and can be disabling.

5. Operative Toolbox Talk & Competent Person Sign-Off Register

Competent Person & Operative Declaration: By signing below, the Site Supervisor confirms this assessment has been adapted and verified for actual site conditions, and operatives confirm they have attended the pre-start Toolbox Talk for Water-Mix Metalworking Fluid (MWF) Sump Oil Mist & Endotoxin Control and will follow the safe system of work.

Operative / Supervisor Name Trade / Role & CSCS No. Signature Date & Time
1. (Site Supervisor):     
2.     
3.     
4.     
5.     
6.     

Related UK Safety Templates & Risk Assessments