SafeSequence › UK Safety Template Library › Sheet Metal & Fabrication › CNC Hydraulic Press Brake Photoelectric Light Curtain & Tooling Changeover
Verified UK SOP Standard • Sheet Metal & Fabrication

CNC Hydraulic Press Brake Photoelectric Light Curtain & Tooling Changeover (SOP Template & 5x5 Risk Assessment)

This Standard Operating Procedure (SOP) establishes mandatory safety requirements for operating CNC hydraulic press brakes equipped with photoelectric light curtain safeguarding systems and performing tooling changeover activities. The document addresses critical hazards including crushing, trapping, shearing, and entanglement risks associated with press brake operations in sheet metal fabrication environments. All operations must comply with the Provision and Use of Work Equipment Regulations 1998 (PUWER), HSG236 Power Presses guidance, and BS EN 12622 Safety of Machine Tools standards. This procedure applies to all competent, trained operators, toolsetters, and maintenance personnel authorised to operate or maintain CNC press brakes. Risk assessments demonstrate residual risks reduced to ALARP (As Low As Reasonably Practicable) through engineering controls, administrative measures, and mandatory PPE. Photoelectric light curtain systems must be functionally tested daily and subject to thorough examination by competent persons at intervals not exceeding 12 months. Tooling changeover operations require isolation under Lock-Out/Tag-Out (LOTO) procedures with stored energy dissipation verification.

Statutory FrameworkPUWER 1998, HSG236 Power Presses, BS EN 12622 Safety of Machine Tools
ClassificationNot applicable - This SOP covers mechanical engineering equipment operation. Hydraulic fluids used in press brake systems are typically ISO VG 32-68 hydraulic oils classified under GHS as Category 3 Aspiration Hazard (H304) and Category 2 Aquatic Chronic Toxicity (H411). Operators must not handle hydraulic fluids; maintenance activities involving hydraulic systems require separate COSHH assessment and competent person authorisation. Emergency spill kits must be available in accordance with Control of Substances Hazardous to Health Regulations 2002 (COSHH).
Required Plant / KitCNC hydraulic press brake with photoelectric light curtain safeguarding system (Type 4 AOPD to BS EN IEC 61496) • Calibrated torque wrench set (20-200 Nm range) for tooling retention bolts • Hydraulic pressure gauge (0-350 bar) for system verification • Mechanical lifting beam or overhead crane with certified slings for heavy punch/die tooling (>25kg) • Portable multi-function electrical safety tester for light curtain functional verification
Review Cycle12 Months / Post-Incident
Instant AI Customization or Free Blank Word (.doc) Download

Need this SOP customized with your Company Name, Site Postcode & Nearest A&E Hospital?

Dictate your site specifics on your phone in 45 seconds to auto-compile a signed PDF—or download our free blank Word (.doc) shell below.

Auto-Fill via Voice / CLP (45s)

2. 5×5 Hazard Risk Assessment Matrix (HASAWA 1974 / MHSWR 1999)

Identified Hazard & HarmInitial Risk (L×S)Mandatory Engineering, Isolation & Procedural ControlsResidual Risk
1. Crushing and trapping between descending ram/punch and lower die during bending cycle
Harm: Catastrophic injuries including traumatic amputation of fingers/hands, crush injuries, fractures, or fatality. Hydraulic press forces typically 60-400 tonnes.
4 × 5 = 20Type 4 photoelectric light curtain (AOPD) to BS EN IEC 61496 with safety-rated control system (PLe/Cat 4 to BS EN ISO 13849-1). Muting function disabled during manual operations. Daily functional test mandatory before production. Two-hand control option for single-stroke mode. Emergency stop devices within 400mm reach. Annual thorough examination by competent person. Minimum safety distance calculation per BS EN ISO 13855 (Ds = K × T + C where K=2000mm/s, T=overall system stopping time). Interlocked guards for rear access zones.2 × 5 = 10
2. Shearing and cutting injuries from sharp punch/die tooling edges during changeover operations
Harm: Deep lacerations to hands/fingers requiring sutures, potential tendon/nerve damage, infection risk from contaminated cutting edges.
4 × 3 = 12Mandatory LOTO isolation procedure before tooling access - electrical isolation with personal padlock, hydraulic pressure relief valve opened and verified at zero bar on gauge. Stored energy dissipation confirmed. Cut-resistant gloves (BS EN 388 Level C minimum) worn during handling. Mechanical lifting aids for tooling >25kg (Manual Handling Operations Regulations 1992 compliance). Tooling stored in designated racks with edge protection. Two-person lift protocol for heavy die sets. Permit-to-work system for complex changeovers.2 × 3 = 6
3. Entanglement of loose clothing, gloves, or long hair in rotating back-gauge drive mechanisms
Harm: Severe degloving injuries, scalping, fractures from rotational forces, potential for dragging operator into machinery.
3 × 4 = 12Fixed guards to BS EN ISO 14120 over all rotating drive components (ball screws, timing belts, servo motors). Prohibition of loose clothing, jewellery, and unsecured long hair (contained in snood/hairnet). Gloves must be removed before operating controls or during active machine cycle. Induction training emphasises entanglement hazards. Routine guard integrity inspections during weekly machine checks. Interlocked access panels with trapped-key systems for maintenance access.1 × 4 = 4
4. Hydraulic fluid injection injuries from high-pressure hose failure (up to 350 bar system pressure)
Harm: Hydraulic fluid injection into tissue causing severe internal damage, potential amputation, systemic toxicity. Medical emergency requiring immediate surgical intervention.
2 × 5 = 10Six-monthly hydraulic hose inspection by competent person with replacement at manufacturer intervals or signs of degradation. Pressure relief valves set and sealed at design pressure. Operators prohibited from hydraulic system maintenance. 'Never use hands to check for leaks' safety signage. Hydraulic schematic and pressure ratings displayed. Maintenance only by hydraulic-competent engineers with appropriate PPE. Hose routing protected from mechanical damage and heat sources. Emergency procedures include immediate medical attention for suspected injection injuries.1 × 5 = 5
5. Electrical shock from damaged light curtain cables or control panel access during fault-finding
Harm: Electric shock potentially causing cardiac arrest, burns, secondary fall injuries. 400V three-phase supply typical for industrial press brakes.
2 × 5 = 10All electrical work by competent electricians only (BS 7671 18th Edition compliance). Light curtain emitter/receiver cables in armoured conduit or protected trunking. IP65-rated enclosures for control panels. Routine PAT testing of portable electrical equipment. LOTO isolation for electrical maintenance with voltage verification before work. RCD protection (30mA) on supply circuits. Operators prohibited from opening electrical enclosures - 'Authorised Electricians Only' signage. Annual fixed electrical installation inspection. Fault-finding only by trained maintenance personnel following safe systems of work.1 × 5 = 5

3. Step-by-Step Safe Sequence of Operations & Hold-Points

1

Conduct Pre-Start Safety Verification and Light Curtain Functional Test

Pre-Operation Checks

Complete daily pre-start checklist: verify emergency stop buttons function correctly (test and reset), inspect light curtain emitter/receiver lenses for contamination or damage, check for visible hydraulic leaks or damaged hoses, confirm back-gauge movement is smooth without obstruction, and verify all guards are in position and secure. Perform mandatory light curtain functional test using test piece (typically 30mm diameter rod) - pass test piece through light field at multiple heights and depths to confirm immediate machine stop response. Record test result in machine logbook. Check hydraulic oil level in sight glass (should be within green zone). Verify work area is clear of obstructions and adequate lighting is available (minimum 500 lux at work surface per HSE guidance). Do not proceed if any defects identified - report to supervisor and tag machine 'DO NOT OPERATE'.

Critical Hold-Point: CRITICAL HOLD POINT: Machine must NOT be operated if light curtain functional test fails or emergency stops do not function correctly. Any safety system defect requires immediate isolation and competent person inspection before return to service. Operating with defective safeguards is a breach of PUWER Regulation 11 and may result in disciplinary action and HSE enforcement.
2

Select and Verify Correct Bending Program and Tooling Configuration

Pre-Operation Checks

Access CNC control panel and select appropriate bending program for workpiece material (grade, thickness), bend angle, and tooling configuration. Verify on-screen that programmed punch and die dimensions match physically installed tooling (check tool identification markings). Confirm back-gauge position settings and bend sequence are correct for job specification. Review programmed ram speed - use reduced speed (typically 10mm/s maximum) for initial setup and first-off verification. Check material thickness input matches actual sheet metal gauge using calibrated vernier caliper. For new or modified programs, conduct dry-run cycle with no material present to verify ram travel and back-gauge movements are correct. Ensure tonnage calculation is within machine capacity (consult tonnage chart for material/tooling combination).

Critical Hold-Point: CRITICAL HOLD POINT: Incorrect tooling selection or programming can result in tool breakage, machine damage, or workpiece ejection. Verify tonnage requirements do not exceed machine capacity (typically indicated by red zone on pressure gauge). Overloading can cause catastrophic hydraulic system failure or structural damage to machine frame.
3

Position Workpiece and Execute Bending Cycle with Light Curtain Active

Operation

Wearing cut-resistant gloves, manually position sheet metal workpiece against back-gauge stops, ensuring material is flat against lower die and square to machine centreline. Remove gloves before operating machine controls (entanglement hazard). Stand in designated operator position (marked floor area) with clear view of bending zone. Activate bending cycle using foot pedal or two-hand control buttons (both hands required for two-hand mode). Ram will descend - do NOT reach into bending zone as light curtain will stop cycle if beam is broken. Monitor bend formation and listen for unusual noises indicating tool misalignment or material slip. Upon cycle completion, ram will automatically return to upper position. Remove completed workpiece only when ram is fully retracted and stationary. For multiple bends, reposition workpiece and repeat cycle. Maintain awareness of light curtain field - avoid unnecessary interruptions that cause production delays.

Critical Hold-Point: CRITICAL HOLD POINT: NEVER attempt to hold, adjust, or remove workpiece during ram descent or while ram is in lower position. Light curtain provides presence-sensing protection but cannot prevent injury if operator deliberately reaches past safeguarding. Any attempt to defeat or bypass light curtain is gross misconduct and criminal offence under Section 37 Health and Safety at Work Act 1974.
4

Isolate Machine Under LOTO Procedure Before Tooling Access

Tooling Changeover

Initiate tooling changeover procedure: Press emergency stop button and select 'SETUP' mode on control panel. Rotate main electrical isolator to 'OFF' position (located on machine side panel) - verify indicator lamp extinguishes. Apply personal LOTO padlock to isolator hasp (each person working on machine applies their own lock). Attach danger tag stating 'DO NOT OPERATE - TOOLING CHANGEOVER IN PROGRESS' with your name and date. Open hydraulic pressure relief valve (quarter-turn valve typically located near pump unit) to dissipate stored energy. Verify zero pressure on hydraulic gauge (needle must indicate 0 bar). Use manual ram descent control (mechanical hand-wheel or manual valve) to lower ram to safe working height for tool access. Chock ram in position using mechanical safety blocks/props if available. Only after complete isolation and energy dissipation may tooling be accessed.

Critical Hold-Point: CRITICAL HOLD POINT: Tooling changeover without proper LOTO isolation has resulted in multiple UK fatalities. Stored hydraulic energy can cause unexpected ram movement even with electrical supply isolated. NEVER rely on control system alone - physical isolation and energy dissipation are mandatory. Each person must apply their own lock - group lockout procedures apply for team changeovers.
5

Remove Existing Tooling and Install Replacement Punch/Die Set

Tooling Changeover

Wearing cut-resistant gloves and safety footwear, use calibrated torque wrench to loosen punch retention bolts (typically M16-M20 grade 8.8) in cross-pattern sequence to prevent binding. For heavy tooling (>25kg), position mechanical lifting beam or attach crane slings before fully removing retention bolts. Carefully lower punch assembly onto padded workbench or tooling cart - never place tooling on floor where trip hazard exists. Clean punch mounting surface on ram using lint-free cloth and inspect for damage or wear. Retrieve replacement punch from tooling storage rack (two-person lift if >25kg per Manual Handling Operations Regulations). Align punch locating features with ram mounting slots and secure using retention bolts. Torque bolts to manufacturer specification (typically 80-120 Nm) in cross-pattern using calibrated torque wrench - record torque values in changeover log. Repeat process for lower die installation, ensuring die is correctly seated in bed mounting. Verify punch and die alignment using feeler gauges or alignment tools before removing safety blocks.

Critical Hold-Point: CRITICAL HOLD POINT: Inadequately secured tooling can eject during operation causing fatal injuries. All retention bolts must be torqued to specification using calibrated torque wrench - 'feel' tightening is not acceptable. Verify tooling identification markings match job specification to prevent incorrect tool installation. Never work beneath unsupported ram - use mechanical safety blocks/props.
6

Remove LOTO, Conduct Post-Changeover Verification and Test Cycle

Return to Service

Remove mechanical safety blocks/props from ram area. Close hydraulic pressure relief valve (turn clockwise until seated - do not overtighten). Remove personal LOTO padlock and danger tag only after confirming all personnel clear of machine and all tools/equipment removed from work area. Restore main electrical isolator to 'ON' position. Conduct post-changeover safety checks: verify all tooling retention bolts are tight (visual check for torque wrench witness marks), confirm no tools or foreign objects in machine bed, re-test light curtain function using test piece, and test emergency stops. Select 'SETUP' mode and conduct slow-speed test cycle with no material present to verify punch/die alignment and clearance. Measure and verify first-off component against job specification using appropriate measuring equipment. Record changeover completion time, personnel involved, and tooling configuration in machine logbook. Return to normal production mode only after successful first-off approval by supervisor or quality inspector.

Critical Hold-Point: CRITICAL HOLD POINT: Post-changeover verification is mandatory before production restart. Operating with misaligned tooling can cause tool breakage, machine damage, or workpiece ejection at high velocity. First production cycle must be conducted at reduced speed in setup mode. Never remove another person's LOTO lock - only the person who applied the lock may remove it (exception: authorised management removal procedure per company LOTO policy in emergency situations).

Emergency Rescue, First Aid & Spill Protocol

EMERGENCY STOP: Immediately press any red mushroom-head emergency stop button (located at operator station, both machine ends, and rear access area) if unsafe condition observed, person in danger zone, or abnormal machine operation occurs. Emergency stops are fail-safe and will immediately cut power to hydraulic pump and engage ram brake. Do not reset emergency stop until hazard is eliminated and area confirmed safe. ENTRAPMENT/CRUSHING INJURY: If person trapped in machine, immediately activate emergency stop and call 999 for emergency services. Do NOT attempt to reverse machine or free trapped person without Fire & Rescue Service hydraulic rescue equipment - uncontrolled release may worsen injuries. Assign person to meet emergency services and guide to incident location. Provide first aid for shock and bleeding control without moving casualty. Preserve scene for HSE investigation. HYDRAULIC INJECTION INJURY: Treat as medical emergency even if entry wound appears minor - hydraulic fluid injection causes severe internal tissue damage. Immediately call 999 and inform that hydraulic injection injury suspected requiring emergency surgical intervention. Do not delay seeking medical attention. Apply light dressing to wound but do not attempt to clean or probe. Keep casualty warm and monitor for shock. Inform medical personnel of hydraulic fluid type (ISO VG grade and safety data sheet available in maintenance office). ELECTRICAL SHOCK: Do NOT touch casualty if still in contact with electrical source. Isolate power using emergency stop or main isolator if safe to do so. If not possible, call 999 immediately. Once safe, check casualty responsiveness and breathing - commence CPR if required (compressions-only CPR acceptable if not trained in rescue breaths). Use automated external defibrillator (AED) located in main workshop office if available. Continue until emergency services arrive. FIRST AID: Trained first aiders available during all production shifts (names and contact numbers displayed on workshop notice board). First aid room located adjacent to main office with eyewash station, stretcher, and trauma supplies. All injuries, regardless of severity, must be recorded in accident book (BI 510) and reported to supervisor immediately. RIDDOR-reportable injuries (>7 days incapacity, specified injuries including amputations/fractures, dangerous occurrences) must be reported to HSE within required timescales - contact Health & Safety Manager immediately on [emergency contact number].

4. UK HSE Compliance FAQs: CNC Hydraulic Press Brake Photoelectric Light Curtain & Tooling Changeover

5. Operative Toolbox Talk & Competent Person Sign-Off Register

Competent Person & Operative Declaration: By signing below, the Site Supervisor confirms this assessment has been adapted and verified for actual site conditions, and operatives confirm they have attended the pre-start Toolbox Talk for CNC Hydraulic Press Brake Photoelectric Light Curtain & Tooling Changeover and will follow the safe system of work.

Operative / Supervisor Name Trade / Role & CSCS No. Signature Date & Time
1. (Site Supervisor):     
2.     
3.     
4.     
5.     
6.     

Related UK Safety Templates & Risk Assessments