This COSHH assessment addresses the control of diesel engine exhaust emissions (DEEE) in enclosed loading bays, warehouses, and depot environments. DEEE contains respirable crystalline silica, nitrogen oxides, carbon monoxide, and carcinogenic particulate matter classified by IARC as Group 1 carcinogen. Under COSHH 2002 (as amended) and HSE HSG187 guidance, employers must eliminate or adequately control exposure through engineering controls, local exhaust ventilation (LEV), operational procedures, and health surveillance. This assessment identifies carcinogenic and respiratory hazards, mandates engineering controls including forced ventilation systems, vehicle emission controls, and strict operational protocols to reduce exposure to as low as reasonably practicable (ALARP). All personnel working in or near enclosed areas where diesel vehicles operate must receive COSHH awareness training and appropriate respiratory protective equipment where engineering controls alone are insufficient.
| Identified Hazard & Harm | Initial Risk (L×S) | Mandatory Engineering, Isolation & Procedural Controls | Residual Risk |
|---|---|---|---|
| 1. Inhalation of carcinogenic diesel particulate matter (DPM) and exhaust gases in poorly ventilated enclosed loading bays Harm: Lung cancer, bladder cancer, chronic obstructive pulmonary disease (COPD), occupational asthma, cardiovascular disease. Long latency period (10-40 years). Irreversible harm. | 4 × 5 = 20 | Engineering: Install and maintain LEV systems with minimum 6-10 air changes per hour. Fit all diesel vehicles with DPF and SCR technology. Implement vehicle idling prohibition (max 1 minute). Use electric or LPG vehicles where practicable. Administrative: Restrict access to loading bays during vehicle operations. Provide RPE (FFP3) where exposure monitoring indicates WEL exceedance. Conduct annual air quality monitoring and health surveillance (respiratory questionnaires, spirometry). LOTO: Interlock ventilation systems with bay door operation—ventilation must activate before vehicle entry. | 3 × 3 = 9 |
| 2. Acute carbon monoxide (CO) poisoning from diesel exhaust accumulation in confined spaces Harm: Headache, dizziness, nausea, loss of consciousness, brain damage, death. CO is odourless and undetectable without monitoring. Fatal at 1600 ppm within 20 minutes. | 3 × 5 = 15 | Engineering: Install fixed CO monitoring systems with audible/visual alarms set at 30 ppm (TWA action level). Ensure forced ventilation achieves adequate dilution. Prohibit vehicle idling in enclosed spaces. Administrative: Issue portable CO monitors to supervisors. Establish emergency evacuation procedures. Train all personnel on CO poisoning symptoms. LOTO: Implement permit-to-work for any hot work or maintenance in areas with potential CO accumulation. Ventilation failure must trigger automatic bay closure and vehicle exclusion. | 2 × 4 = 8 |
| 3. Nitrogen dioxide (NO₂) exposure causing respiratory irritation and sensitisation Harm: Acute bronchitis, pulmonary oedema, reduced lung function, increased susceptibility to respiratory infections. Asthmatics at higher risk. WEL: 0.5 ppm (15-min STEL). | 4 × 3 = 12 | Engineering: Maintain LEV systems to HSE standards with 14-month thorough examination and test (TExT). Use low-NOx diesel engines and AdBlue SCR systems. Ensure adequate natural and mechanical ventilation. Administrative: Monitor NO₂ levels using direct-reading instruments during peak operations. Rotate workers to limit exposure duration. Exclude pregnant workers and asthmatics from high-exposure tasks. LOTO: Ventilation system maintenance requires isolation, LOTO procedures, and temporary work suspension in affected areas. | 2 × 3 = 6 |
| 4. Dermal contact with diesel fuel and oils containing carcinogenic PAHs during refuelling and maintenance Harm: Occupational dermatitis, skin sensitisation, skin cancer (prolonged exposure). PAHs are absorbed through skin and metabolised to carcinogenic compounds. | 3 × 3 = 9 | Engineering: Install closed refuelling systems with automatic shut-off nozzles. Provide wash stations with skin-friendly cleansers (not solvents). Use drip trays and spill kits. Administrative: Enforce mandatory use of nitrile gloves (BS EN ISO 374-1:2016). Prohibit use of diesel/petrol for hand cleaning. Provide pre-work skin protection creams and post-work cleansers. Conduct skin surveillance for early dermatitis detection. LOTO: Refuelling operations require engine shutdown, ignition key removal, and LOTO of vehicle systems during tank maintenance. | 2 × 2 = 4 |
| 5. Vehicle strike and crush injuries due to reduced visibility from exhaust smoke and fumes in loading bays Harm: Serious crush injuries, fractures, traumatic amputations, fatalities. Pedestrian-vehicle collisions are leading cause of workplace transport deaths in UK. | 3 × 5 = 15 | Engineering: Implement segregated pedestrian walkways with physical barriers. Install proximity detection systems and reversing cameras/alarms on all vehicles. Ensure adequate lighting (minimum 200 lux in loading areas). Use high-visibility floor markings. Administrative: Enforce mandatory hi-vis PPE (Class 2/3). Implement one-way traffic systems and banksman protocols. Prohibit pedestrian access during vehicle movements. Provide refresher training on workplace transport safety. LOTO: Vehicle immobilisation (chocks, park brake, LOTO ignition) mandatory during loading/unloading operations. | 2 × 4 = 8 |
Before commencing operations in enclosed loading bays, the Competent Person (COSHH trained) must review the site-specific COSHH assessment for DEEE. Verify that all engineering controls are operational: check LEV system is functioning (visual inspection of airflow indicators, check last TExT certificate dated within 14 months), confirm all diesel vehicles are fitted with operational DPF/SCR systems (check maintenance records), and verify fixed CO/NO₂ monitoring systems are calibrated and alarmed. Review air quality monitoring data from previous shifts. Identify number of vehicle movements planned and duration of operations. Confirm emergency procedures and muster points are communicated to all personnel.
Activate forced mechanical ventilation systems minimum 10 minutes before first vehicle entry to establish adequate air changes. Confirm airflow direction is from clean to contaminated areas with exhaust discharge away from building air intakes and occupied areas. Establish and mark exclusion zones for non-essential personnel—only trained, authorised personnel with appropriate PPE permitted in loading bay during vehicle operations. Post warning signage: 'DIESEL EXHAUST HAZARD - CARCINOGEN - AUTHORISED PERSONNEL ONLY - RPE REQUIRED'. Ensure emergency exits are unobstructed and emergency lighting functional.
Direct vehicles to enter loading bay only when designated loading position is available—no queuing with engines running inside enclosed space. Drivers must switch off engines immediately upon reaching loading position (maximum 1-minute idling permitted for manoeuvring only). Use electric pallet trucks or tugs for vehicle positioning where practicable. Ensure vehicle exhaust outlets are directed away from personnel work areas and air intakes. Banksman to coordinate movements using standard hand signals or radio communication. Maintain segregation between pedestrians and vehicles at all times using designated walkways.
Once vehicle is positioned, driver must: apply park brake, switch off engine, remove ignition key, and deploy wheel chocks. For vehicles requiring power for tail-lift operation, limit engine-on time to minimum necessary. Loading personnel must wear mandatory PPE including FFP3 RPE if air monitoring indicates exposure above action level (0.025 mg/m³ elemental carbon). Minimise time spent in immediate vicinity of exhaust outlets. Use mechanical handling equipment to reduce manual handling and exposure duration. Supervisor to monitor real-time CO levels using portable monitor—if CO exceeds 30 ppm, evacuate personnel and increase ventilation or reduce vehicle numbers.
Upon completion of loading/unloading, remove wheel chocks and signal driver to start engine. Vehicle must exit loading bay promptly without unnecessary idling. Banksman to ensure pedestrian exclusion zone maintained during vehicle exit. Once vehicle has departed, conduct spot-check air monitoring using portable gas detector (CO, NO₂) and record results in COSHH monitoring log. For personnel wearing personal air sampling equipment, ensure pumps are stopped and samples logged for laboratory analysis. Review exposure data against WEL and action levels. Maintain ventilation operation for minimum 10 minutes after last vehicle departure to purge residual emissions.
Supervisor must complete daily COSHH monitoring log including: number of vehicle movements, duration of operations, air monitoring results, any control failures or near-misses, and personnel exposure hours. File records for minimum 40 years (carcinogen exposure records). Ensure all personnel exposed to DEEE are enrolled in health surveillance programme including: baseline and annual respiratory questionnaires, spirometry for high-exposure workers, and occupational health review for any respiratory symptoms. Report any cases of work-related ill-health to HSE under RIDDOR. Conduct monthly review of COSHH assessment effectiveness and update following any changes to operations, vehicle fleet, or ventilation systems.
EMERGENCY RESPONSE FOR DIESEL EXHAUST EXPOSURE INCIDENTS: **Carbon Monoxide Poisoning (Acute Emergency):** - Symptoms: Headache, dizziness, nausea, confusion, loss of consciousness, cherry-red skin (late sign) - Immediate Action: Evacuate casualty to fresh air immediately. Call 999 and request ambulance stating "suspected carbon monoxide poisoning". Administer high-flow oxygen (15 L/min via non-rebreather mask) if trained and equipment available. Monitor consciousness and breathing. Be prepared to commence CPR if casualty becomes unresponsive and not breathing normally. - Do NOT re-enter contaminated area without appropriate RPE (BA) and gas monitoring equipment. **Respiratory Distress from DEEE/NO₂ Exposure:** - Symptoms: Coughing, wheezing, chest tightness, shortness of breath, throat irritation - Immediate Action: Remove casualty from exposure to fresh air. Loosen tight clothing. Place in comfortable position (usually sitting upright). Call 999 if symptoms severe or not improving within 10 minutes. Administer reliever inhaler if casualty has prescribed medication. Monitor breathing and consciousness. Delayed pulmonary oedema may occur up to 24 hours post-exposure—advise casualty to seek medical review if symptoms develop or worsen. **Diesel Fuel Skin Contact:** - Immediate Action: Remove contaminated clothing. Wash affected skin thoroughly with soap and water for minimum 10 minutes. Do NOT use solvents or abrasive cleaners. Apply emollient cream. Seek medical advice if irritation persists or skin damage evident. Contaminated clothing must be laundered before re-use. **Diesel Fuel Eye Contact:** - Immediate Action: Irrigate eyes with clean water or sterile eyewash for minimum 15 minutes, holding eyelids open. Remove contact lenses if present and easy to do. Seek medical attention—diesel fuel can cause corneal damage. **EMERGENCY CONTACTS:** - Emergency Services: 999 - HSE Incident Contact Centre: 0345 300 9923 - National Poisons Information Service (for clinical advice): 0344 892 0111 - Site Emergency Coordinator: [Insert site-specific contact] **RIDDOR REPORTING:** Any case of acute CO poisoning requiring medical treatment, or diagnosis of occupational lung disease/cancer attributed to DEEE exposure, must be reported to HSE under RIDDOR 2013. Maintain incident records for minimum 3 years.
Under COSHH Regulation 11, health surveillance is MANDATORY where employees are exposed to substances associated with a particular disease or adverse health effect (e.g., lung cancer from DEEE) and there is a reasonable likelihood of the disease occurring under the particular conditions of work. For DEEE, which is an IARC Group 1 carcinogen, health surveillance must include: (1) Pre-placement baseline respiratory health assessment; (2) Periodic health surveillance (typically annual) including respiratory symptom questionnaire and spirometry for workers with significant exposure; (3) Maintenance of individual health records for 40 years from last exposure; (4) Referral to occupational health physician if abnormalities detected. HSE guidance HSG61 'Health Surveillance at Work' and HSG187 specifically address DEEE. Employers must ensure health surveillance is conducted by competent occupational health professionals and that workers are informed of surveillance results. Failure to provide adequate health surveillance is a breach of COSHH and may result in HSE enforcement action including Improvement Notices or prosecution.
LEV adequacy for DEEE control must be determined through: (1) Competent design to HSE HSG258 'Controlling Airborne Contaminants at Work' achieving minimum 6-10 air changes per hour for general loading bays, or higher for intensive operations; (2) Commissioning tests demonstrating adequate capture velocity and airflow rates; (3) Personal and static air monitoring to verify exposure below WEL (0.05 mg/m³ elemental carbon 8-hr TWA). Under COSHH Regulation 9, LEV systems must be thoroughly examined and tested (TExT) at least every 14 months by a competent person (typically P601-qualified LEV engineer). TExT must include visual inspection, airflow measurements at key points, and assessment of effectiveness. Results must be recorded and retained for 5 years. Between TExT, daily/weekly user checks should verify system operation (e.g., airflow indicators, pressure gauges). If air monitoring shows WEL exceedance despite LEV operation, the system is inadequate and must be upgraded—increased RPE alone is not acceptable as primary control for carcinogens. HSE expects hierarchy of control with engineering measures prioritised over PPE.
The selection of RPE for DEEE must be based on: (1) Adequate protection factor to reduce exposure below WEL; (2) Suitability for carcinogen exposure (DEEE is IARC Group 1). FFP2 provides Assigned Protection Factor (APF) of 10, while FFP3 provides APF of 20. Given that DEEE is a carcinogen with no safe threshold, HSE expects use of RPE with adequate protection factor based on exposure monitoring data. If air monitoring shows exposure at or above WEL (0.05 mg/m³), FFP3 is the MINIMUM acceptable for filtering facepiece respirators. For higher exposures, half-mask or full-face respirators with P3 filters (APF 20-40) may be required. Under COSHH Regulation 7, RPE is only acceptable as a control measure where engineering controls are insufficient or during maintenance/emergency situations—it must not be used as primary long-term control. To address comfort issues: (1) Ensure correct face-fit through mandatory face-fit testing (HSE INDG479); (2) Trial different FFP3 models—various designs available with improved comfort features; (3) Implement RPE wearing time limits with job rotation; (4) Prioritise engineering control improvements to reduce reliance on RPE. Downgrading to FFP2 for comfort without exposure data justification would breach COSHH duty to provide adequate control and could expose employer to HSE enforcement and civil liability if workers develop occupational disease.
Competent Person & Operative Declaration: By signing below, the Site Supervisor confirms this assessment has been adapted and verified for actual site conditions, and operatives confirm they have attended the pre-start Toolbox Talk for Diesel Engine Exhaust Emissions (DEEE) in Enclosed Loading Bays & Depots and will follow the safe system of work.
| Operative / Supervisor Name | Trade / Role & CSCS No. | Signature | Date & Time |
|---|---|---|---|
| 1. (Site Supervisor): | |||
| 2. | |||
| 3. | |||
| 4. | |||
| 5. | |||
| 6. |