SafeSequence › UK Safety Template Library › Surface Prep & Flooring › Industrial Warehouse Slab Diamond Grinding & M-Class Dust Extraction (RCS)
Verified UK RAMS Standard • Surface Prep & Flooring

Industrial Warehouse Slab Diamond Grinding & M-Class Dust Extraction (RCS) (RAMS Template & 5x5 Risk Assessment)

This Risk Assessment and Method Statement (RAMS) addresses the diamond grinding of industrial warehouse concrete slabs with integrated M-Class dust extraction to control Respirable Crystalline Silica (RCS) exposure. The document ensures compliance with COSHH 2002 (EH40 WEL 0.1 mg/m³ for RCS), Control of Noise at Work Regulations 2005, and HAVS management requirements. All operatives must be competent, trained in RCS hazards, and equipped with appropriate RPE (FFP3 minimum). Engineering controls including on-tool M-Class extraction (≥99.9% efficiency) and wet suppression are mandatory. Work must be supervised by a competent person with documented pre-start checks, air monitoring, and health surveillance records maintained. This RAMS applies to all diamond grinding operations on concrete warehouse floors and must be reviewed before each shift.

Statutory FrameworkCOSHH 2002 (Respirable Crystalline Silica EH40 WEL 0.1 mg/m3), Control of Noise at Work 2005, HAVS
ClassificationRespirable Crystalline Silica (RCS) - CAS 14808-60-7. GHS Classification: STOT RE 1 (H372 - Causes damage to lungs through prolonged or repeated inhalation). UK EH40 Workplace Exposure Limit (WEL): 0.1 mg/m³ 8-hour TWA. Silicosis risk with chronic exposure. Material is non-flammable but dust clouds may present explosion risk in confined spaces. Concrete dust pH typically 12-13 (alkaline) - skin/eye irritant. No UN transport classification for solid concrete but airborne RCS requires strict occupational controls per COSHH 2002 (as amended 2004). Ensure Safety Data Sheets (SDS) for all grinding consumables and sealers are available on-site.
Required Plant / KitIndustrial diamond grinding machine (230-400mm head) with integrated shroud and M-Class dust extraction port • M-Class vacuum extractor (H13 HEPA filter, ≥99.9% efficiency, tested to BS EN 60335-2-69, minimum 100 L/s airflow) • Water suppression system with flow regulator (minimum 0.5 L/min) or wet grinding attachment • Calibrated personal air sampling pumps and RCS sampling heads (IOM or CIP10) for exposure monitoring • Vibration-dampened handles and anti-vibration gloves (tested to ISO 10819) for HAVS control
Review Cycle12 Months / Post-Incident
Instant AI Customization or Free Blank Word (.doc) Download

Need this RAMS customized with your Company Name, Site Postcode & Nearest A&E Hospital?

Dictate your site specifics on your phone in 45 seconds to auto-compile a signed PDF—or download our free blank Word (.doc) shell below.

Auto-Fill via Voice / CLP (45s)

2. 5×5 Hazard Risk Assessment Matrix (HASAWA 1974 / MHSWR 1999)

Identified Hazard & HarmInitial Risk (L×S)Mandatory Engineering, Isolation & Procedural ControlsResidual Risk
1. Respirable Crystalline Silica (RCS) inhalation from concrete grinding dust
Harm: Silicosis (irreversible lung scarring), lung cancer, COPD, chronic respiratory disease. Latency period 10-20+ years.
5 × 5 = 25Engineering: M-Class extraction (≥99.9% efficiency) with on-tool shroud, wet suppression minimum 0.5 L/min, regular filter changes per manufacturer schedule. Administrative: Rotate operatives to limit exposure <6 hours, personal air monitoring (IOM sampler) quarterly, health surveillance (respiratory questionnaire + spirometry) annually per HSE G404. RPE: Face-fit tested FFP3 minimum, clean-shaven policy. Isolation: Barrier off work area minimum 5m, signage 'RCS Hazard - Authorised Personnel Only'. Housekeeping: HEPA vacuum only (never dry sweep), wet wipe surfaces, controlled waste disposal (double-bag, label 'Contains RCS').3 × 3 = 9
2. Hand-Arm Vibration Syndrome (HAVS) from prolonged grinding tool operation
Harm: Permanent nerve damage, vibration white finger, loss of manual dexterity, circulatory disorders in hands/fingers.
4 × 4 = 16Engineering: Select low-vibration grinders (<2.5 m/s² A(8) where practicable), maintain equipment (balanced heads, replace worn bearings), vibration-dampened handles. Administrative: Trigger time calculator per HSE HAVS calculator, maximum 2-hour continuous use then 30-min break, daily exposure limit 2.5 m/s² A(8) EAV, health surveillance (tier system per HSE L140) including annual questionnaire and circulation tests. PPE: Anti-vibration gloves (ISO 10819), keep hands warm/dry. Training: Correct grip technique (avoid excessive force), recognise early symptoms (tingling, numbness).2 × 3 = 6
3. Noise exposure exceeding 85 dB(A) Lower Exposure Action Value
Harm: Noise-Induced Hearing Loss (NIHL), tinnitus, permanent threshold shift, communication difficulties.
5 × 3 = 15Engineering: Specify quieter grinders where available, maintain equipment (worn bearings increase noise), acoustic barriers/screens around work area. Administrative: Noise assessment (octave band analysis) pre-start, hearing protection zones marked, limit exposure duration, rotate operatives. PPE: Class 4/5 hearing protection (SNR ≥25dB) to reduce exposure <80 dB(A), dual protection (plugs + muffs) if >100 dB(A). Health surveillance: Baseline + annual audiometry per HSE L108. Training: Correct insertion of earplugs, consequences of non-compliance.3 × 2 = 6
4. Manual handling of heavy grinding equipment (30-80kg) and risk of musculoskeletal injury
Harm: Back strain, herniated discs, shoulder/knee injuries, chronic musculoskeletal disorders.
4 × 3 = 12Engineering: Mechanical aids (trolleys, lifting equipment) for transport, two-person lift for equipment >25kg, height-adjustable handles to reduce stooping. Administrative: Manual handling training per HSE guidelines, pre-task dynamic risk assessment, team lifts mandatory, kinetic lifting technique (bend knees not back). Elimination: Store equipment at waist height, minimise carry distances, plan route (clear obstacles). Supervision: Competent person to oversee lifts, stop work if unsafe posture observed. Health surveillance: Pre-placement musculoskeletal screening, report injury/discomfort immediately.2 × 2 = 4
5. Electrical hazards from 110V/230V grinding equipment and M-Class extractor in wet conditions
Harm: Electric shock, electrocution (potentially fatal), burns, cardiac arrest.
3 × 5 = 15Engineering: 110V CTE (centre-tapped earth) supply mandatory for portable tools, RCD protection (30mA trip) on all circuits, IP-rated equipment (minimum IP54 for wet use), insulated cables with no damage. LOTO: Isolation procedure before maintenance, lockable isolator, test before touch. Administrative: Daily pre-use inspection (PAT label in-date, cable integrity, plug condition), competent electrician for repairs only, never bypass safety devices. Segregation: Keep cables away from grinding path, cable management (suspend overhead or protect), dry hands before handling controls. Emergency: Clearly marked isolation points, trained first-aiders, AED available.1 × 5 = 5

3. Step-by-Step Safe Sequence of Operations & Hold-Points

1

Site Survey, Isolation, and Equipment Inspection

Pre-Start Preparation & Site Setup

Conduct site walkdown to identify services (electric, water, gas, data) and mark on floor plan. Obtain Permit to Work if required. Establish exclusion zone minimum 5m radius with barriers and signage ('RCS Hazard Area - RPE Required'). Verify mechanical ventilation adequate (minimum 6 air changes/hour) or provide local exhaust ventilation. Inspect grinding equipment: check PAT label (in-date), cable integrity, shroud secure, M-Class extractor H13 filter clean (<50% loaded), water supply connected and flow-tested (≥0.5 L/min). Verify all operatives hold valid face-fit certificates (FFP3, <12 months old) and HAVS health surveillance is current. Complete pre-start checklist and obtain supervisor sign-off.

Critical Hold-Point: HOLD POINT: Do not proceed until M-Class extractor pre-separator and H13 filter are confirmed clean and airflow tested (minimum 100 L/s). Defective extraction is the primary cause of RCS overexposure. Supervisor must verify and sign checklist.
2

PPE Donning and Face-Fit Check

Personal Preparation & RPE Donning

All operatives must wash hands and face before donning RPE. Don FFP3 respirator following manufacturer instructions: position over nose and mouth, secure straps (bottom then top), perform positive and negative pressure seal checks per HSE INDG479. If seal fails, adjust or replace respirator - do not enter work area. Don anti-vibration gloves (ensure dry and undamaged), safety boots (S3 rated), and insert hearing protection (earplugs first if using dual protection). High-visibility clothing mandatory if mobile plant operating nearby. Supervisor to visually verify correct PPE donning before entry to exclusion zone. Record operative name, RPE type, and time on-site in daily log.

Critical Hold-Point: STOP: If you cannot achieve a satisfactory face-fit seal (air leakage detected during positive/negative pressure check), you must NOT enter the RCS hazard area. Inform supervisor immediately - alternative RPE (PAPR) or exclusion from task required. Facial hair prevents effective seal.
3

M-Class Extractor Start-Up and Personal Air Sampling Deployment

Equipment Start-Up & Baseline Monitoring

Start M-Class extractor first and allow to run for 30 seconds to verify suction (check manometer/indicator light shows normal operation). Connect extraction hose to grinder shroud with secure coupling (no gaps). If wet grinding, open water valve and verify flow rate using flow meter (target 0.5-1.0 L/min). Deploy personal air sampling pump on operative's breathing zone (lapel-mounted IOM sampler, calibrated flow 2 L/min) if scheduled monitoring day. Start grinder at low speed initially to verify vibration levels acceptable (<2.5 m/s² if possible). Check noise levels with sound level meter - if >85 dB(A) confirm hearing protection in place for all within 10m. Record start time for HAVS exposure calculation (trigger time log).

Critical Hold-Point: CRITICAL: Never operate grinder without M-Class extraction running and shroud fully engaged. Even brief dry grinding generates RCS concentrations >10x WEL. If extractor fails (loss of suction, filter blockage alarm), STOP work immediately, evacuate area, and do not restart until repaired and tested.
4

Controlled Grinding with Continuous Monitoring

Grinding Operations

Maintain steady, controlled passes with grinder - avoid excessive downward pressure (increases vibration and dust). Keep shroud in full contact with floor surface. Monitor water flow continuously (wet grinding) - if slurry dries out, stop and increase flow. Operative to self-monitor for HAVS symptoms (tingling, numbness) and take immediate break if detected. Supervisor to conduct visual checks every 30 minutes: extraction hose secure, no visible dust escape, operative technique correct, PPE still in place. Enforce mandatory 10-minute break every 2 hours of grinding (HAVS control). Rotate operatives if multiple grinders in use to distribute exposure. Keep non-essential personnel outside exclusion zone. If grinding near services, use cable avoidance tool (CAT) and hand-dig trial holes before deep grinding.

Critical Hold-Point: MANDATORY BREAK: After 2 hours continuous grinding (trigger time), operative MUST take minimum 30-minute break away from vibration and RCS area. Remove RPE in clean area, wash face and hands. Supervisor to enforce - no exceptions. Exceeding daily EAV (2.5 m/s² A(8)) triggers health surveillance escalation.
5

Safe Shutdown, Filter Change, and Wet Cleaning

Shutdown & Decontamination

Switch off grinder and allow to come to complete stop before setting down. Continue running M-Class extractor for additional 2 minutes to clear residual dust from hose. Close water valve (wet grinding). Disconnect extraction hose carefully (residual dust may be present - wear RPE). If filter change required (per manufacturer schedule or blockage indicator), perform in well-ventilated area or outdoors: seal used filter in heavy-duty polythene bag, label 'Contains RCS - Dispose as Hazardous Waste', wash hands immediately. Never blow out filters with compressed air. Wet-clean all equipment surfaces using HEPA vacuum followed by damp cloth - never dry brush or blow down. Coil cables and hoses neatly, inspect for damage. Store equipment in designated clean area away from welfare facilities.

Critical Hold-Point: CONTAMINATION CONTROL: Used H13 filters contain concentrated RCS and must be double-bagged, sealed, and labeled before disposal. Do NOT shake, tap, or blow filters. Perform filter changes wearing FFP3 RPE in well-ventilated area. Wash hands thoroughly before eating, drinking, or smoking.
6

HEPA Vacuum, Waste Disposal, and Record Completion

Site Clearance & Documentation

Use HEPA vacuum (never standard vacuum or broom) to clean entire work area including 5m perimeter. Wet-wipe all horizontal surfaces (barriers, tools, signage) with damp cloth - dispose of cloths as RCS waste. Collect grinding slurry (wet method) and place in sealed drums labeled 'Concrete Slurry - Contains RCS'. Arrange disposal via licensed waste carrier (EWC code 17 01 06* - mixtures containing dangerous substances). Remove barriers and signage only after cleaning verified by supervisor. Complete daily records: operative hours (for HAVS exposure calculation), air sampling data (if conducted), equipment inspection results, any incidents or near-misses. Submit personal air samples to UKAS-accredited laboratory for RCS analysis (results within 14 days). Debrief team on lessons learned and update RAMS if required.

Critical Hold-Point: HOLD POINT: Supervisor must visually inspect cleaned area and verify no visible dust residue before removing barriers and reopening to general access. Air sampling results >0.05 mg/m³ (50% WEL) trigger immediate control review and re-sampling. All RCS waste must be disposed via licensed carrier - never general waste.

Emergency Rescue, First Aid & Spill Protocol

**Emergency Contacts:** Site First Aider (name/number on site notice board), Emergency Services 999, HSE Incident Contact Centre 0345 300 9923 (RIDDOR reporting). **RCS Overexposure:** If RPE fails or operative exposed to visible dust cloud: immediately evacuate to fresh air, remove contaminated clothing, wash exposed skin thoroughly. Monitor for respiratory distress (coughing, shortness of breath) - if symptoms develop, seek medical attention and inform clinician of RCS exposure. Report incident to supervisor and HSE if significant exposure suspected. **Electric Shock:** Do NOT touch casualty if still in contact with live equipment. Isolate power at source (RCD/isolator). If casualty unconscious, call 999 immediately, commence CPR if trained and safe to do so. Use AED if available. **HAVS Symptoms:** If operative reports tingling, numbness, blanching of fingers, or loss of dexterity: stop work immediately, record symptoms in HAVS surveillance log, refer to Occupational Health within 48 hours. Do not allow return to vibration work until cleared by OH. **Noise Trauma:** Sudden hearing loss or severe tinnitus after noise exposure: cease work, refer to Occupational Health urgently. Do not re-expose to noise >80 dB(A) until assessed. **First Aid Kit:** BS 8599-1 compliant kit must be available on-site with eye wash station (for alkaline dust contact). All injuries, however minor, must be recorded in accident book and reported to supervisor. RIDDOR-reportable injuries (>7 days incapacity, specified injuries, dangerous occurrences) must be reported to HSE within required timescales.

4. UK HSE Compliance FAQs: Industrial Warehouse Slab Diamond Grinding & M-Class Dust Extraction (RCS)

5. Operative Toolbox Talk & Competent Person Sign-Off Register

Competent Person & Operative Declaration: By signing below, the Site Supervisor confirms this assessment has been adapted and verified for actual site conditions, and operatives confirm they have attended the pre-start Toolbox Talk for Industrial Warehouse Slab Diamond Grinding & M-Class Dust Extraction (RCS) and will follow the safe system of work.

Operative / Supervisor Name Trade / Role & CSCS No. Signature Date & Time
1. (Site Supervisor):     
2.     
3.     
4.     
5.     
6.     

Related UK Safety Templates & Risk Assessments