SafeSequence › UK Safety Template Library › COSHH & Chemical Safety › Acetone & Methyl Ethyl Ketone (MEK) Industrial Solvent Degreasing
Verified UK COSHH Standard • COSHH & Chemical Safety

Acetone & Methyl Ethyl Ketone (MEK) Industrial Solvent Degreasing (COSHH Template & 5x5 Risk Assessment)

This COSHH assessment addresses the safe use of acetone and methyl ethyl ketone (MEK) for industrial solvent degreasing operations. Both substances are highly flammable liquids (GHS02) and present inhalation, skin contact, and fire/explosion hazards. Compliance with COSHH 2002, DSEAR 2002, and EH40/2005 Workplace Exposure Limits (500 ppm 8-hour TWA for both substances) is mandatory. Controls include local exhaust ventilation (LEV) achieving minimum 0.5 m/s capture velocity, explosion-proof equipment in ATEX-classified zones, closed transfer systems, and comprehensive permit-to-work procedures. All operatives must hold valid COSHH awareness training and demonstrate competence in emergency spill response. Atmospheric monitoring is required at intervals not exceeding 14 days where exposure approaches 50% of the WEL. This document establishes the minimum standard for solvent degreasing activities and must be read in conjunction with site-specific DSEAR risk assessments and emergency arrangements.

Statutory FrameworkCOSHH 2002, DSEAR 2002, EH40/2005 WEL (500 ppm TWA), CLP (GHS02, GHS07)
Classification**UN/GHS Classification:** - **Acetone:** UN1090, Class 3 Flammable Liquid, Packing Group II. GHS02 (Flame), GHS07 (Exclamation Mark). H225 (Highly flammable liquid and vapour), H319 (Causes serious eye irritation), H336 (May cause drowsiness or dizziness). EUH066 (Repeated exposure may cause skin dryness or cracking). - **Methyl Ethyl Ketone (MEK):** UN1193, Class 3 Flammable Liquid, Packing Group II. GHS02 (Flame), GHS07 (Exclamation Mark). H225 (Highly flammable liquid and vapour), H319 (Causes serious eye irritation), H336 (May cause drowsiness or dizziness). EUH066 (Repeated exposure may cause skin dryness or cracking). - **UK WEL (EH40/2005):** Acetone: 500 ppm (1210 mg/m³) 8-hour TWA, 1500 ppm (3620 mg/m³) 15-min STEL. MEK: 200 ppm (600 mg/m³) 8-hour TWA, 300 ppm (899 mg/m³) 15-min STEL. Skin notation applies to MEK. - **DSEAR Classification:** Both substances form flammable vapour/air mixtures. Lower Explosive Limit (LEL): Acetone 2.5% v/v, MEK 1.4% v/v. Requires ATEX zoning and ignition source control.
Required Plant / KitLocal Exhaust Ventilation (LEV) system with ATEX-rated extraction fan (minimum 0.5 m/s capture velocity at source, LEV examination certificate valid within 14 months as per COSHH Regulation 9) • Explosion-proof (ATEX Zone 1 rated) electrical equipment and lighting within 3-metre radius of solvent handling area • Closed solvent transfer system with bonding and earthing cables (resistance <10 ohms verified before each use) • Intrinsically safe atmospheric monitoring equipment calibrated for acetone and MEK vapour detection (alarm set at 10% LEL and 50% WEL) • Type II safety cabinet for flammable liquids (BS EN 14470-1 compliant) with 30-minute fire resistance and self-closing doors
Review Cycle12 Months / Post-Incident
Instant AI Customization or Free Blank Word (.doc) Download

Need this COSHH customized with your Company Name, Site Postcode & Nearest A&E Hospital?

Dictate your site specifics on your phone in 45 seconds to auto-compile a signed PDF—or download our free blank Word (.doc) shell below.

Auto-Fill via Voice / CLP (45s)

2. 5×5 Hazard Risk Assessment Matrix (HASAWA 1974 / MHSWR 1999)

Identified Hazard & HarmInitial Risk (L×S)Mandatory Engineering, Isolation & Procedural ControlsResidual Risk
1. Inhalation of acetone/MEK vapours exceeding WEL during degreasing operations
Harm: Acute CNS depression (headache, dizziness, nausea, loss of consciousness), respiratory tract irritation, chronic neurotoxic effects with repeated overexposure. Exceeding 500 ppm TWA breaches COSHH Regulation 7.
4 × 4 = 16Install and maintain LEV system achieving minimum 0.5 m/s capture velocity at source (LEV examination every 14 months per COSHH Reg 9). Conduct atmospheric monitoring at 14-day intervals using calibrated direct-reading instruments. Implement permit-to-work for tasks exceeding 50% WEL. Enforce respiratory protection (BS EN 14387 Type A2 filters) where engineering controls insufficient. Provide COSHH awareness training (refreshed annually) covering WEL significance and symptom recognition. Restrict access to authorised, trained operatives only.2 × 2 = 4
2. Fire or explosion from ignition of flammable vapour/air mixture (LEL: acetone 2.5%, MEK 1.4%)
Harm: Catastrophic fire/explosion causing multiple fatalities, severe burns (full-thickness), structural collapse, and environmental release. DSEAR 2002 Regulation 6 breach.
3 × 5 = 15Implement ATEX zoning (minimum Zone 2 within 3m radius of open solvent handling). Use only ATEX-certified explosion-proof equipment (Zone 1 rated). Enforce hot work permit system with 60-minute pre-work atmospheric monitoring (<10% LEL mandatory). Install bonding and earthing for all transfer operations (verify <10 ohms resistance). Prohibit smoking, naked flames, and non-intrinsically safe devices within 10m exclusion zone. Store solvents in Type II safety cabinets (BS EN 14470-1). Maintain portable fire extinguishers (CO₂ or dry powder, minimum 6kg) within 10m travel distance. Conduct DSEAR competent person review annually.2 × 3 = 6
3. Dermal contact causing defatting dermatitis, skin sensitisation, and systemic absorption (MEK 'Skin' notation)
Harm: Severe dermatitis with cracking/bleeding, allergic contact sensitisation, systemic toxicity via dermal absorption contributing to WEL exceedance. Occupational skin disease reportable under RIDDOR 2013.
4 × 3 = 12Enforce mandatory use of chemical-resistant gloves (nitrile/butyl, BS EN ISO 374-1 Type B, >60 min breakthrough time). Implement closed transfer systems to eliminate manual handling. Provide immediate access to eyewash/emergency shower (BS EN 15154 compliant, <10 seconds travel time). Conduct pre-placement and annual skin surveillance by occupational health professional. Supply emollient barrier creams (applied before work) and after-work moisturisers. Prohibit eating, drinking, smoking in solvent areas. Enforce strict hand hygiene protocols before breaks.2 × 2 = 4
4. Acute eye irritation/damage from splashes during solvent transfer or spill response (H319)
Harm: Serious eye irritation with pain, lacrimation, corneal damage, temporary vision impairment. Potential permanent scarring if not irrigated immediately.
3 × 3 = 9Mandate chemical splash goggles (BS EN 166:2001, rating 3-4) or full-face respirator during all handling operations. Install emergency eyewash stations (BS EN 15154-2, <10 seconds access, weekly activation test). Use closed transfer systems with quick-disconnect couplings to minimise splash risk. Provide face shields for decanting operations. Train all operatives in immediate 15-minute irrigation protocol. Ensure first aiders hold valid Emergency First Aid at Work certificate with chemical injury module.2 × 2 = 4
5. Confined space entry for tank cleaning with residual solvent vapours and oxygen-deficient atmosphere
Harm: Asphyxiation, loss of consciousness within seconds, CNS depression, fire/explosion in oxygen-enriched re-entry. Fatality risk high; multiple confined space deaths annually in UK.
3 × 5 = 15Implement Confined Spaces Regulations 1997 permit-to-work system. Conduct pre-entry atmospheric testing (O₂ 19.5-23%, <10% LEL, <50% WEL) using calibrated multi-gas detector. Enforce continuous forced ventilation (minimum 6 air changes/hour) with ducted fresh air supply. Mandate supplied-air breathing apparatus (BS EN 137:2006) or airline respirator—never rely on filters alone. Station trained standby person outside with rescue equipment (tripod, winch, harness). Lockout/tagout all energy sources and blank off pipework. Limit entry duration to 30 minutes with mandatory atmospheric re-test. Ensure rescue plan tested annually.1 × 4 = 4

3. Step-by-Step Safe Sequence of Operations & Hold-Points

1

Pre-task risk assessment, permit-to-work authorisation, and atmospheric baseline monitoring

Preparation & Permit Authorisation

Conduct toolbox talk covering task-specific hazards, emergency procedures, and WEL/LEL limits. Complete permit-to-work form signed by competent supervisor (minimum IOSH Managing Safely qualified). Verify LEV system operational (check manometer/Magnehelic gauge against baseline—investigate >10% deviation). Conduct baseline atmospheric monitoring at breathing zone height (1.5m) and floor level (vapours heavier than air) using calibrated detector. Record results: O₂ 19.5-23%, LEL <10%, acetone/MEK <50% WEL (250 ppm). Confirm emergency eyewash/shower functional (weekly test log current). Verify fire extinguishers in date (annual service sticker). Establish 3m exclusion zone with barrier tape and signage ('Flammable Solvents in Use—No Smoking/Hot Work—Authorised Personnel Only').

Critical Hold-Point: **HOLD POINT:** Do NOT proceed if LEV system inoperative, atmospheric monitoring shows >10% LEL or >50% WEL, or permit not authorised. Evacuate area and notify supervisor immediately.
2

Don mandatory PPE, verify bonding/earthing, and prepare closed transfer system

PPE Donning & Equipment Setup

Don anti-static coveralls, chemical-resistant gloves (inspect for tears/degradation—discard if compromised), and chemical splash goggles. If respiratory protection required (exposure >50% WEL or LEV inadequate), fit-test and don full-face respirator with Type A2 organic vapour filters (check expiry date and seal integrity via negative pressure test). Connect bonding cable from solvent drum to earthed degreasing tank—verify resistance <10 ohms using multimeter. Attach closed transfer pump (air-operated diaphragm type, ATEX-rated) with quick-disconnect couplings. Position drip tray (minimum 110% drum capacity) beneath transfer point. Ensure spill kit (absorbent pads, disposal bags, PPE) within 5m reach. Double-check all electrical equipment is ATEX Zone 1 certified.

Critical Hold-Point: **HOLD POINT:** Verify bonding resistance <10 ohms before ANY solvent transfer. Static discharge can ignite vapours at concentrations as low as 1.4% v/v (MEK LEL). Do NOT use non-ATEX equipment within 3m radius.
3

Transfer acetone/MEK to degreasing tank using closed system with continuous monitoring

Solvent Transfer & Degreasing Tank Charging

Activate LEV system to maximum extraction rate before opening solvent containers. Slowly transfer solvent via closed pump system at rate not exceeding 10 litres/minute to minimise vapour generation and static buildup. Maintain continuous atmospheric monitoring—alarm set at 10% LEL and 50% WEL. Keep drum bung partially open to prevent vacuum formation but minimise vapour escape. Fill degreasing tank to maximum 75% capacity to allow vapour space and prevent overflow. Avoid splashing or turbulent flow. Once transfer complete, immediately reseal drum and return to Type II safety cabinet. Wipe any minor spillage with solvent-dampened cloth (dispose in sealed metal waste container). Record volume transferred and atmospheric readings on permit.

Critical Hold-Point: **HOLD POINT:** If atmospheric monitor alarms (>10% LEL or >50% WEL), STOP transfer immediately. Activate emergency ventilation, evacuate non-essential personnel, and allow vapour levels to drop below alarm thresholds before resuming. Investigate cause (LEV failure, transfer rate too high, leak).
4

Immerse components in solvent bath with controlled agitation and exposure time limits

Component Degreasing Operations

Using long-handled tongs or basket (never hands, even with gloves), immerse contaminated components into degreasing tank. Maintain LEV capture velocity at source (verify airflow indicator). Agitate gently if required—avoid vigorous splashing that increases vapour release. Limit immersion time to minimum necessary (typically 2-5 minutes for effective degreasing). For heavily soiled items, use pre-wipe with disposable cloths to reduce solvent contamination. Work in batches to minimise tank lid open time—keep lid closed when not actively degreasing. Conduct atmospheric monitoring every 30 minutes during continuous operations. Rotate operatives every 2 hours to limit individual exposure duration. Maintain task log recording start/finish times and cumulative exposure.

Critical Hold-Point: **HOLD POINT:** If operative experiences symptoms of overexposure (headache, dizziness, nausea, eye irritation), cease work immediately, move to fresh air, and seek first aid assessment. Report incident to supervisor—may indicate LEV failure or WEL exceedance requiring immediate investigation.
5

Air-dry degreased components in ventilated area and segregate contaminated waste

Component Drying & Waste Handling

Remove degreased components and allow to drain over tank for 30 seconds. Transfer to designated drying rack positioned within LEV extraction zone. Allow minimum 10 minutes air-drying before handling or further processing—solvent evaporates rapidly but vapour concentration remains hazardous. Do NOT use compressed air for drying (creates aerosol and static). Dispose of solvent-contaminated cloths, gloves, and absorbent materials in sealed metal waste container (self-closing lid, UN-approved for flammable waste). Label container 'Hazardous Waste—Flammable Solvent Residues—UN1090/UN1193'. Arrange collection by licensed waste carrier (Hazardous Waste Regulations 2005 consignment note required). Never dispose of solvents down drains—environmental offence under Environmental Protection Act 1990.

Critical Hold-Point: **HOLD POINT:** Do NOT accumulate >50 litres of solvent-contaminated waste in work area. Spontaneous combustion risk from heat of evaporation in confined containers. Arrange immediate removal to external hazardous waste store (minimum 10m from buildings, bunded, fire-resistant construction).
6

Secure solvent tank, decontaminate equipment, conduct final atmospheric check, and close permit

Shutdown, Decontamination & Permit Closure

Ensure degreasing tank lid fully closed and secured. Disconnect and drain transfer pump into drip tray—flush with small volume of fresh solvent and allow to evaporate in ventilated area. Disconnect bonding cables and return to storage. Conduct final atmospheric monitoring at breathing zone and floor level—record on permit (must be <10% LEL and <50% WEL before permit closure). Remove and dispose of single-use PPE in hazardous waste container. Decontaminate reusable PPE (goggles, respirator facepiece) using detergent and water—never use solvent to clean PPE. Wash hands thoroughly with soap and water. Complete permit closure section including actual exposure duration, atmospheric readings, and any incidents/near-misses. Submit permit to supervisor for review and filing (retain for minimum 5 years per COSHH Regulation 12). Remove exclusion zone barriers only after final atmospheric check confirms safe levels.

Critical Hold-Point: **HOLD POINT:** Do NOT leave solvent tank unsealed or unattended. Overnight vapour accumulation can create explosive atmosphere by morning. If work interrupted, secure tank, post warning signage, and conduct pre-start atmospheric check before resuming.

Emergency Rescue, First Aid & Spill Protocol

**Emergency Procedures:** - **Fire/Explosion:** Activate fire alarm, evacuate area, call 999. Do NOT attempt firefighting unless trained and safe to do so. Use CO₂ or dry powder extinguishers on small fires (<1m²)—never use water (spreads flammable liquid). Evacuate to assembly point minimum 50m upwind. Account for all personnel. Inform Fire & Rescue Service of solvent type, quantities, and ATEX zoning. - **Large Spill (>5 litres):** Evacuate area, eliminate ignition sources, activate emergency ventilation. Cordon off 10m radius. Notify emergency services if spill enters drains/watercourses (environmental incident). Trained spill response team to don full PPE including supplied-air BA. Use inert absorbent (vermiculite, sand—never sawdust/combustible material). Collect in UN-approved containers. Ventilate area until atmospheric monitoring confirms <10% LEL. - **Small Spill (<5 litres):** Eliminate ignition sources, ventilate area. Don appropriate PPE. Absorb with spill kit materials. Dispose as hazardous waste. Decontaminate area with detergent and water. **First Aid (call 999 for serious exposure):** - **Inhalation:** Remove casualty to fresh air immediately. If unconscious, place in recovery position and monitor breathing. Administer oxygen if trained and available. Seek immediate medical attention if symptoms persist (headache, dizziness, nausea). Inform medics of substance (acetone/MEK) and exposure duration. - **Skin Contact:** Remove contaminated clothing immediately (treat as hazardous waste). Wash affected area with copious soap and water for minimum 15 minutes. Do NOT use solvents to clean skin. Apply emollient cream. Seek medical attention if irritation/dermatitis develops. Report to occupational health for skin surveillance. - **Eye Contact:** Irrigate eyes immediately at emergency eyewash station for minimum 15 minutes, holding eyelids open. Remove contact lenses if present and easy to do. Seek immediate medical attention—transport to A&E with SDS. Continue irrigation en route if possible. - **Ingestion (rare):** Do NOT induce vomiting (aspiration risk). Rinse mouth with water. Give small amounts of water to drink if conscious. Seek immediate medical attention. Provide SDS to medical personnel. **Reporting:** All exposures, spills, or near-misses must be reported to supervisor immediately. Incidents causing injury, loss of consciousness, or requiring medical treatment are reportable under RIDDOR 2013 (report to HSE within 10 days via online system). Maintain accident book (BI 510) records.

4. UK HSE Compliance FAQs: Acetone & Methyl Ethyl Ketone (MEK) Industrial Solvent Degreasing

5. Operative Toolbox Talk & Competent Person Sign-Off Register

Competent Person & Operative Declaration: By signing below, the Site Supervisor confirms this assessment has been adapted and verified for actual site conditions, and operatives confirm they have attended the pre-start Toolbox Talk for Acetone & Methyl Ethyl Ketone (MEK) Industrial Solvent Degreasing and will follow the safe system of work.